I

f the crimping diameter is not within the range of tolerance for that particular hose type, cut the hose 

end and repeat the crimping operation. 

 
 

 

 

 

To have verification of correct crimping, carry out a check with a vernier. 

 

Measure  the  diameter  of  the  second and  third  rings  of  the  swaged  ferrule and 
check that the value is included in the crimping dimensional tolerance of ± 0,1mm  

(see table number 1 - page 5). 

 

During  this  measurement  rotate  the  hose  end  so  that  you  can  verify  if  the 
machine is making a proper round crimping. 

Measurement of the third ring of the ferrule

 

Measurement of the second ring of the ferrule

 

WARNING! 

WHEN ASSEMBLING AN ELBOW FEMALE DO NOT MOVE NOR ROTATE IT, 
OTHERWISE YOU RISK TO DAMAGE OR EVEN BREAK THE INSERT INSIDE THE 
HOSE COMPROMISING THE ENTIRE HOSE ASSEMBLY. 

 

Содержание GOMAX QUADRA DN2

Страница 1: ...ng machine It is essential to fulfil the training process in the hose assembly procedures in order to make high quality Transfer Oil GOMAX QUADRA DN2 DN4 and DN6 hose assemblies Transfer Oil GOMAX QUA...

Страница 2: ...en in the preparation of this data sheet but Transfer Oil is not responsible for any inadvertent typographical errors or omissions Information subject to change without notice The information in these...

Страница 3: ...imping machines available on the market some manufacturers and models of suitable hydraulic crimping machines are listed below UNIFLEX HYDRAULIC GmbH model HM200 FINN POWER model P20 O P S r l model T...

Страница 4: ...imping machine as used by Transfer Oil for the production of GOMAX QUADRA hose assemblies If the indicated die sets are not available for the customers selected crimping machine then before ordering t...

Страница 5: ...gle with a tolerance of 5 We recommended the use of the cutter WXA004 Assembling the ferrule and the insert Slip the nut over the hose depending on fitting type Ensure that the threaded side is pointi...

Страница 6: ...t way in order to achieve the final crimping diameter of the ferrules Refer to table 1 of this procedure to select the correct set of dies and the correct crimping diameter 4 2 Crimping Assembling GOM...

Страница 7: ...hose end is finished check the correct positioning of the components make sure that the entire surface of the ferrule has been swaged make sure that the crimped ferrule and the insert are correctly po...

Страница 8: ...and third rings of the swaged ferrule and check that the value is included in the crimping dimensional tolerance of 0 1mm see table number 1 page 5 During this measurement rotate the hose end so that...