Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in  
the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output, please check 
the fixtures specifications as to which your unit accepts.

 
 
 
Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

CABL10 – 2m

CABL11 – 5m

CABL12 – 10m

3-Pin:

CABL185 – 2m

CABL187 – 5m

CABL188 – 10m

5-Pin:

Содержание UP2-RF

Страница 1: ...Order code BOTE32 UP2 RF Dimmer Controller User Manual ...

Страница 2: ...nit Do not open the equipment and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cabl...

Страница 3: ... a switch pack LED Display makes it easy to set DMX channels HTP function 3 Pin XLR input output Output 2 x IEC Socket Easy to use mounting bracket Maximum Power 10A UP2 RF Dimmer Controller Specifications Power supply 230V 50Hz Fuse F10A 250V Dimensions 182 x 92 x 68mm Weight 1 1kg Order code BOTE32 01 2 x IEC outputs 02 LED display 03 HTP fader 04 Menu button 05 Up button 06 Down button 07 Exter...

Страница 4: ...matically stored into the units memory Press the MENU button until the display shows d Press the UP or DOWN button so the display shows S Press the MENU button to enter switch pack mode Use the UP or DOWN buttons to change between S on and S oF Press the MENU button to exit switch pack mode In Switch pack on mode the output is on and the fixture will illuminate regardless of the DMX signal In swit...

Страница 5: ...e the UP or DOWN buttons to change the value between 10 100 Use the UP or DOWN buttons to change the value between 00 100 Once the dimmer preset is selected it will be automatically stored into the units memory Press the MENU button exit out of any of the above options Press the MENU button to enter Dimmer preset mode MENU MENU Please note The HTP Fader MUST be at value 0 for the DMX to operate co...

Страница 6: ...f different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX addres...

Страница 7: ... a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal tr...

Страница 8: ...nt possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmen...

Отзывы: