2.5” Solid State Drive

 

Transcend Information Inc.

 

 Preliminary V1.0 

15

the drive can be unlocked using the master password. 

If the user password is lost and Maximum security level is set, it is impossible to access data. However, the drive can be 

unlocked using the ERASE UNIT command with the master password. The drive will erase all user data and unlock the 

drive. 

SATA Optional Features 

Power Segment Pin P11 

Pin P11 of the power segment of the device connector may be used by the device to provide the host with an activity 

indication. The activity indication provided by pin P11 is primarily for use in backplane applications. 

Asynchronous Signal Recovery 

Phy may support asynchronous signal recovery for those applications where the usage model of device insertion into a 

receptacle (power applied at time of insertion) does not apply. 

When signal is lost, both the host and the device may attempt to recover the signal. A host or device shall determine loss 

of signal as represented by a transition from PHYRDY to PHYRDYn, which is associated with entry into states LSI: 

NoCommErr or LS2:NoComm within the Link layer. Note that negation of PHYRDY does not always constitute a loss of 

signal. Recovery of the signal is associated with exit from state LS2:NoComm. If the device attempts to recover the 

signal before the host by issuing a COMINIT, the device shall return its signature following completion of the OOB 

sequence which included COMINIT. If a host supports synchronous signal recovery, when the host receives an 

unsolicited COMINIT, the host shall issue a COMRESET to the device. An unsolicited COMINIT is a COMINIT that was 

not in response to a preceding COMRESET, as defined by the host not being in the HP2:HR_AwaitCOMINIT state when 

the COMINIT signal is first received. 

When a COMRESET is sent to the device in response to an unsolicited COMINIT, the host shall set the Status register to 

7Fh and shall set all other Shadow Command Block Registers to FFh. When the COMINIT is received in response to the 

COMRESET which is associated with entry into state HP2B:HR_AwaitNoCOMINIT, the Shadow Status register value 

shall be updated to either FFh or 80h to reflect that a device is attached. 

Содержание TS120GSSD25D-M

Страница 1: ...r high end system such as server and storage system Build in advance ECC and global wear leveling provide a durable solution is perfect replacement storage device for Server systems Storage systems PC...

Страница 2: ...5 pins combo connector Environmental Specifications Operating Temperature 0 to 70 Storage Temperature 40 to 85 Performance Model P N Sequential Read Max Sequential Write Max TS60GSSD25D M 210 MB s 150...

Страница 3: ...MTBF 1 5M hours Endurance 60GB 75 7 years 20GB write day 120GB 151 4 years 20GB write day Vibration Operating 5 0G 15 800Hz Non Operating 5 0G 15 800Hz Note Reference to the IEC 60068 2 6 Testing proc...

Страница 4: ...D M M M T T TS S S1 1 12 2 20 0 0G G GS S SS S SD D D2 2 25 5 5D D D M M M 2 5 Solid State Drive Transcend Information Inc Preliminary V1 0 4 Package Dimensions Below figure illustrates the Transcend...

Страница 5: ...D D D2 2 25 5 5D D D M M M 2 5 Solid State Drive Transcend Information Inc Preliminary V1 0 5 Pin Assignments Pin No Pin Name Pin No Pin Name 01 GND 02 A 03 A 04 GND 05 B 06 B 07 GND 08 NC 09 NC 10 NC...

Страница 6: ...S SD D D2 2 25 5 5D D D M M M 2 5 Solid State Drive Transcend Information Inc Preliminary V1 0 6 Block Diagram Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flas...

Страница 7: ...veling When the free blocks erase count is higher than the data blocks it will activate the static wear leveling replacing the not so frequently used user blocks with the high erase count free blocks...

Страница 8: ...6 60 0 0G G GS S SS S SD D D2 2 25 5 5D D D M M M T T TS S S1 1 12 2 20 0 0G G GS S SS S SD D D2 2 25 5 5D D D M M M 2 5 Solid State Drive Transcend Information Inc Preliminary V1 0 8 Supported ATA Co...

Страница 9: ...subcommand sets In order to select a subcommand the host must write the subcommand code to the device s Features Register before issuing the SMART Function Set command The subcommands are listed belo...

Страница 10: ...dated Attribute Values to the device s Attribute Data sector regardless of the state of the Attribute Autosave feature SMART Execute Off line Immediately subcommand D4h This subcommand causes the devi...

Страница 11: ...G GS S SS S SD D D2 2 25 5 5D D D M M M T T TS S S1 1 12 2 20 0 0G G GS S SS S SD D D2 2 25 5 5D D D M M M 2 5 Solid State Drive Transcend Information Inc Preliminary V1 0 11 Error log data structure...

Страница 12: ...ough 20 The data structure contains the descriptor of the Self test that the device has performed Each descriptor is 24 bytes long and the self test data structure is capable to contain up to 21 descr...

Страница 13: ...will not affect any of the Attribute Values SMART Disable Operations subcommand D9h This subcommand disables all SMART capabilities After receipt of this subcommand the device disables all SMART oper...

Страница 14: ...F8h Enable Automatic Off line A value of zero written by the host into the device s Sector Count register before issuing this subcommand shall cause the automatic off line data collection feature to...

Страница 15: ...ice shall determine loss of signal as represented by a transition from PHYRDY to PHYRDYn which is associated with entry into states LSI NoCommErr or LS2 NoComm within the Link layer Note that negation...

Страница 16: ...00h Reserved 49 2F00h Capabilities 50 4000h Capabilities 51 52 0200h PIO Mode support 53 0007h Reserved 54 3FFFh Number of current logical cylinders 55 0010h Number of current logical heads 56 003Fh N...

Страница 17: ...required for security erase unit completion 90 0000h Time required for Enhanced security erase completion 91 0000h Current advanced power management value 92 0000h Master Password Revision Code 93 00...

Страница 18: ...duct Transcend reserves the right to make changes to the specifications at any time without prior notice USA Los Angeles E mail sales transcendusa com Maryland E mail sales_md transcendusa com www tra...

Отзывы: