CHAPTER 1:  INTRODUCTION TO THE TRANSCELL TC-200 SERIES DIGITAL COUNTING 

SCALE 

 
The Transcell Model TC-200 Series Digital Counting Scale is an easy to use, high-resolution 
counting scale featuring keyboard tare and unit weight entry. It is equipped with many useful 
features that are normally found on more expensive scale products, including memory 
accumulator and target values. 
 
The scale is available in four avoirdupois weight capacities and four metric weight capacities. 
Table 1-1 shows the TC-200 series product matrix. 
 
Prior to using the scale, please read this user’s guide carefully and completely.  Store the manual 
in a safe and convenient place so it will be available if you have questions concerning the 
operation of the scale. 
 
 
 
 

MODEL 

CAPACITY / GRADUATION 

MODE

L

 

CAPACITY / GRADUATION 

TC-200-6 

6 x 0.0005 lb 

TC-200-3M 

3000 g x 0.2 g 

TC-200-12 

12 x 0.001 lb 

TC-200-6M 

6000 g x 0.5 g 

TC-200-30 

30 x 0.002 lb 

TC-200-15M 

15 x 0.001 kg (1 g) 

TC-200-60 

60 x 0.005 lb 

TC-200-30M 

30 x 0.002 kg (2 g) 

TABLE 1-1: TC-200 Series Product Matrix 

 
 
 
 

TARGET

MC

ENT

7

8

9

0

MR

M+

ZERO

PRINT

2

3

4

5

CLR

SAMPLE

TARE

MODEL

TC-200

6

1

UNIT

SET

ADD

MEM

MR

TARE

lb

kg

LIGHT

WEIGHT

APW

PIECES

TGT

 

 

FIGURE 1-1: TC-200 Series Front Panel 

 
 

 

 

Содержание TC-200-12

Страница 1: ...sion 1 4 December 15 2003 2001 2003 Transcell Technology Inc Contents subject to change without notice Transcell Technology Inc 975 Deerfield Parkway Buffalo Grove IL 60089 Tel 847 419 9180 Fax 847 419 1515 E mail transcell transcell net Web www transcell net ...

Страница 2: ... 3 6 Clearing the Piece Count 10 Chapter 4 Advanced Features and Operation 12 4 1 Average Piece Weight Entry 12 4 1 1 APW Entry from Scale 12 4 1 2 APW Entry from Remote Scale 12 4 2 Memory Accumulator 12 4 2 1 Displaying the Memory Accumulator 12 4 2 2 Adding to the Memory Accumulator 12 4 2 3 Clearing the Memory Accumulator 12 4 3 Using the Target Value 13 Chapter 5 Configuration 14 5 1 Configur...

Страница 3: ...ont Panel 5 2 1 TC 200 Back Panel 6 2 2 Latitude Compensation Zones USA 7 3 1 TC 200 Display Detail 8 3 2 Function and Numeric Keys Layout 9 5 1 User Menu Key Assignments 14 5 2 User Menu Chart 14 B 1 Pin Assignments for COM1 Serial Port 22 B 2 Cable Diagram for Scale to Dot Matrix Printer 22 B 3 Cable Diagram for Scale to Computer 22 B 4 Default Print Format 23 B 5 Consolidated Controls Demand Mo...

Страница 4: ...tibility Statement for North America This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not ins...

Страница 5: ...ies product matrix Prior to using the scale please read this user s guide carefully and completely Store the manual in a safe and convenient place so it will be available if you have questions concerning the operation of the scale MODEL CAPACITY GRADUATION MODEL CAPACITY GRADUATION TC 200 6 6 x 0 0005 lb TC 200 3M 3000 g x 0 2 g TC 200 12 12 x 0 001 lb TC 200 6M 6000 g x 0 5 g TC 200 30 30 x 0 002...

Страница 6: ...ts area of use locate the Model A41408 North America or Model SA10 1208U International AC Adapter 2 Connect the female end of the AC Adapter to the connector on the rear of scale and then plug the adapter into an AC outlet Make sure that the AC voltage appearing at the wall outlet matches the input voltage marked on the AC adapter Step 3 If applicable install the serial printer or a computer to th...

Страница 7: ...etroit Minneapolis Chicago Boston Miami St Louis Houston Atlanta Dallas Philadelphia Denve Los Angeles San Francisco Seattle 46o 43o 40o NY 37o 34o 31o 28o 14 13 12 11 10 9 8 7 Figure 2 2 Latitude Compensation Zones USA 7 ...

Страница 8: ...has been established in the system LB KG Indicates the unit of the displayed weight LIGHT Indicates that the APW of the items you are sampling or manually entering is too light for the scale to process accurately ADD Indicates that total weight of the items you are sampling is too light for the scale to process accurately MEM Indicates that the value of the piece count accumulator is greater than ...

Страница 9: ...rmation S MC This key is used to clear the piece count accumulator MR This key is used to briefly display the contents of the piece count accumulator M This key is used to add the currently displayed number of pieces to the piece ount accumulator c Decimal Point This key is used to enter a decimal point when entering numeric alues v 0 9 These keys are used to enter numeric and alphanumeric data in...

Страница 10: ...minus weight and turns the TARE annunciator on 2 Place the material to be weighed in the container and allow the weight indication to stabilize 3 Read the weight shown on the display 3 3 4 CLEARING A TARE 1 To clear a tare press the ZERO key at any time The TARE annunciator disappears and the gross weight is displayed 3 3 5 PIECE COUNTING This mode is used to indicate the number of pieces of an it...

Страница 11: ...ece Weight Minimum Sample Weight TC 200 6 6 x 0 0005 lb 0 0004 lb 0 0125 lb TC 200 12 12 x 0 001 lb 0 0008 lb 0 025 lb TC 200 30 30 x 0 002 lb 0 0016 lb 0 050 lb TC 200 60 60 x 0 005 lb 0 004 lb 0 125 lb TC 200 3M 3000 g x 0 2 g 0 16 g 5 g TC 200 6M 6000 g x 0 5 g 0 4 g 12 5 g TC 200 15M 15 x 0 001 kg 1 g 0 8 g 25 g TC 200 30M 30 x 0 002 kg 2 g 1 6 g 50 g TABLE 3 2 TC 200 Sampling Limits 11 ...

Страница 12: ...ransmit APW Mode See TC 100 or PBS Series manual for more information 1 Perform the sampling on the remote scale 2 Press the PRINT key on the remote scale If the APW is large enough the TC 200 scale will now display the number of pieces on the scale If it does not the TC 200 scale briefly displays an error message but still allows piece counting Please see Appendix C for an explanation of the erro...

Страница 13: ... now display the number of pieces on the scale If it does not the scale lights one of the error annunciators but still allows piece counting If this occurs you should use a higher sample amount to achieve better piece count accuracy Please see Table 3 1 for an explanation of the error annunciators NOTE1 If the scale displays a Error 10 message the unit weight of the items you wish to count is too ...

Страница 14: ...n When the scale shows F 1 you are in Setup Menu mode and you may release the 0 key 5 2 2 NAVIGATING IN THE SETUP MENU Use the directional keys shown in Figure 3 1 to move around in the Setup Menu Chart shown in Figure 3 2 on the following page Detailed descriptions of the Setup Menu can be found in Chapter 4 1 To move to a new F heading use the 4 left or 5 right key to move right or left in the S...

Страница 15: ...h 2 Power on the scale as normal The display will go through a digit check then settle into Normal Operating mode All front panel keys will now return to their normal mode of operation 5 3 USER A MENU 5 3 1 ENTERING THE USER MENU 1 Toggle the ON OFF switch to the OFF 0 position 2 Press and hold the 8 key while powering back on the scale When the scale shows A 1 you are in User Menu mode and you ma...

Страница 16: ...mmed USER MENU MODE KEY FUNCTIONS 2 ENT 4 5 SET 1 Figure 5 1 User Menu Key Assignments A1 Baud Rate 1200 2400 4800 9600 A2 Data Bits Parity 8n 7O 7E A3 Transmission Mode C d A4 Display Check Press 2 key to begin A7 ID No Enable A8 ID No Entry Press 2 key to begin A6 Serial Port Mode 0 1 0 1 A9 of LF Entry Press 2 key to begin 2 A10 AAWI Enable 0 1 Figure 5 3 User Menu Chart2 5 3 3 EXITING THE USER...

Страница 17: ...2 key to scroll down one level begins the test sequence Press 2 key to begin sequence A6 Serial Port Mode Selects the mode of the RS 232C serial port 0 Full Duplex Mode 1 Print Ticket Mode 2 Transmit APW Mode 0 1 2 A7 ID No Enable Allows the ID No to be disabled in the printout Valid only when A6 is set to 1 0 Disable the ID No 1 Enable the ID No 0 1 A8 ID No Entry Actuates the function that allow...

Страница 18: ...r entering the exact value press the ENT key to save the ID Number value The display will show END ID momentarily then revert back up to A8 5 4 2 LF Line Feeds Number Entry A9 1 While in the User Menu mode scroll to A 9 then scroll down once using the 2 key to enter the Line Feeds menu 2 The display will momentarily show ET LF followed by the current line feeds value 3 Use the front panel numeric ...

Страница 19: ...riod for the load cell and electronic components to become thermally stable 4 Remove all items from the scale s platter Press ZERO to zero the value 5 Press the ENT key to save the zero point value The scale shows 0 000 on the left screen C 1 on the middle screen and a value on the right screen The C 1 indicates that the scale is prompting for the first span calibration value The value to the righ...

Страница 20: ... 8 lb to 12 lb TC 200 30 30 x 0 002 lb 0 3 lb 20 lb to 30 lb TC 200 60 60 x 0 005 lb 0 6 lb 40 lb to 60 lb TC 200 3M 3000 x 0 2 g 30 g 2 kg to 3 kg TC 200 6M 6000 x 0 5 g 60 g 4 kg to 6 kg TC 200 15M 15 x 0 001 kg 1 g 150 g 10 kg to 15 kg TC 200 30M 30 x 0 002 kg 2 g 300 g 20 kg to 30 kg TABLE 6 1 Minimum Recommended Calibration Test Weights 20 ...

Страница 21: ...Tactile Keypad OVER CAPACITY ANNUNCIATION 103 of Full Scale Capacity OPERATING TEMPERATURE RANGE 32 F to 104 F 0 C to 40 C POWER SOURCE AC Adapter 12VDC 800 mA included COM1 SERIAL PORT Full Duplex RS 232 DSUB9F WEIGHT Net Weight 11 0 lb 4 9 kg Shipping Weight 16 lb 7 2 kg PHYSICAL DIMENSIONS 3 94 in 100 mm 10 63 in 270 mm 10 04 in 255 mm 8 86 in 225 mm 13 39 in 340 mm 21 ...

Страница 22: ...ter Figure B 3 shows a suggested cable diagram for a PC type computer The cable shown in Figure B 3 is a standard Transcell cable Model NMC 1 1 Plug the serial device cable not included directly into the DSUB9 serial port connector Pin No Pin Name 2 Receive Data 3 Transmit Data Signal Level RS 232 RS 232 5 Signal Ground RS 232 2 3 5 Front View Figure B 1 Pin assignments for the COM1 serial port co...

Страница 23: ...ative Weight Data Units lb pound kg kilogram Gross Net GR Gross NT Net Start Transmission Carriage Return Line Feed SP SP Space Space FIGURE B 5 Consolidated Controls Demand Mode P This command is sent to the scale to print the indicated display The scale will not respond if the scale is in motion positive overload or negative overload Z This command is sent to the scale to zero the scale If the s...

Страница 24: ...e Weight Data Units L pound K kilogram Gross Net G Gross N Net Start Transmission Carriage Return Line Feed Status SP Valid M Motion O Over under range FIGURE B 6 Consolidated Controls Continuous Mode B 1 4 TRANSMIT APW MODE The Transmit APW Mode is designed specifically for connection to any of the following TC Series scale models TC 2001 TC 2005 TC 2010 Its purpose is to allow APW s derived on t...

Страница 25: ...Err 11 Keyed in sample value is equal to zero or is a fractional value Key in a valid sample value Err 12 Indicates that the APW of the items you are sampling or manually entering is too light for the scale to process accurately Err 13 Indicates that total weight of the items you are sampling is too light for the scale to process accurately Err 14 The keyed in value for APW is equal to zero or exc...

Страница 26: ...ou have chosen exceeds the scale s capacity Err 1 Indicates that the test weight value you have chosen is less than 1 of the scale s capacity Err 2 Occurs when you do not place the test weight on the scale during calibration Can also indicate that there is an internal error in the scale 26 ...

Страница 27: ...d to repair replacement or credit of equipment of parts The warranty does not extend coverage to labor material freight or service charges involved in removal shipping or reinstallation of equipment or parts CONDITIONS WHICH VOID LIMITED WARRANTY This warranty shall not apply to equipment which A Examination of such goods discloses that the nonconformity exists and was caused by accident misuse ne...