Neptune 5500
20
F16
Zero
Calibration
Places indicator into the zero calibration routine. Scroll down with the
DOWN ARROW key one level begins the procedure.
Press DOWN
ARROW key to
begin sequence
F17
Span
Calibration
Places indicator into the span calibration routine. Scroll down with the
DOWN ARROW key one level begins the procedure.
Press DOWN
ARROW key to
begin sequence
F18
View Calibra-
tion
Actuates the function that allows you to view both the zero and span
calibration value. The values displayed in this function are valid only
after Calibration (F16 & F17) has been successfully completed. Scroll
down with the DOWN ARROW key one level begins the procedure.
Press DOWN
ARROW key to
begin sequence
F19
Key-in Zero
Allows you to key-in known zero calibration value in case of memory
loss in the field. Scroll down with the DOWN ARROW key one level
begins the procedure. Use the left and right arrow keys to select the
digit and the up and down arrow keys to adjust the digit. Set key to
save.
Press DOWN
ARROW key to
begin sequence
F20
Key-in Span
Allows you to key-in a known span calibration value in case of mem-
ory loss in the field. Scroll down with the DOWN ARROW key one
level begins the procedure. Use the left and right arrow keys to select
the digit and the up and down arrow keys to adjust the digit. Set key
to save.
Press DOWN
ARROW key to
begin sequence
F21
Factory Reset
This sub-menu will reset all parameters in the “F” and “A” menu to the
default settings. USE WITH CAUTION!
Press the DOWN
ARROW to
execute.
F23
Scale Capacity
Allows user to set the capacity of the scale.
2.5, 5, 10, 25, 50,
100, 250, 00,1000
F24
Check Weigh
ON or OFF
Allows user to enable check weigh function to allow entry of set point
values for over/under check weighing.
Also allows user to disable check weigh function so the display acts
as a traditional indicator where the units key repeats the available
units selections and does not prompt for set point values.
1
√
– ON
0 - OFF