Trans instruments Marine Salt Testa Скачать руководство пользователя страница 2

  

 
1. PRECAUTION

 

The 

Marine  Salt  testa

  is  for  the  sole  purpose  of  measuring  the 

Temperature, Salinity and Specific Gravity of natural seawater and / 
or  synthetic  seawater.  This  meter  has  been  factory  calibrated  and 
performance tested to ensure accurate readings. 
 
Please  read  the  entire  operation  manual  before  using  this 

Marine 

Salt  testa

.    Failure  to  read  this  manual  prior  usage  may  result  in 

equipment damage and will void the warranty. 

 
1.1 Notes on safety 

 

Please keep this product away from children. Ingestion of small 
parts may lead to choking and serious injury. If the sensor 
protection cap or battery is ingest; please consult a physician 
immediately. 
Be careful not to scratch the surface of the platinum-plated 
sensors. 
Do not use chemicals such as acetone or benzene for cleaning as 
it may cause deterioration of the plastic housing. 
Never attempt to disassemble or modify this product, this will void 
warranty. 

 
1.2 Notes during measurement  

 

Always rinse the Probe Sensor before and after each test. 

Make sure sensor do not contact any of the walls of the 
aquarium or sump while in measurement mode.  Keep sensors 
at least 1cm away from all sides and bottom of the measuring 
container.

    

 
  1.3 Notes on storage 

 

Avoid keeping 

Marine Salt testa

 in high humidity environments, 

direct exposure to sunlight, high temperatures, dust and 
moisture to prevent damage. 
Please keep sensor cap in-place to protect the sensors when not 
in use. 
Always remove the batteries if tester is not use over a long 
period of more than one month.

 

 

!!!!

!!!!

!!!!

Содержание Marine Salt Testa

Страница 1: ... 8 1 8 1 2 7 2 7 6 3 6 3 4 5 4 5 Operation Manual Marine Salt Testa Digital meter for the measurement of salinity specific gravity and temperature ...

Страница 2: ...areful not to scratch the surface of the platinum plated sensors Do not use chemicals such as acetone or benzene for cleaning as it may cause deterioration of the plastic housing Never attempt to disassemble or modify this product this will void warranty 1 2 Notes during measurement Always rinse the Probe Sensor before and after each test Make sure sensor do not contact any of the walls of the aqu...

Страница 3: ...Temperature measurement in a cyclical mode This button is also use to change the display units of temperature C F see section 6 The HOLD button is use to hold the measurement value during a test Pressing it again will resume continuous measurement This button is also use for performing Calibration in Salinity mode See section 5 MODE SEL HOLD CAL ON OFF HOLD CAL Button MODE SEL Button ON OFF Button...

Страница 4: ...1 000 1 037 Is displayed when battery level is low and replacement of battery is needed 3 Product Specification Salinity Specific Gravity Temperature Measurement Range 0 50ppt 1 000 1 037sg 0 70 C 32 158 F Resolution 1ppt 0 001sg 0 1 C 0 2 F Accuracy 2ppt 0 002sg 1 C 2 F Operating Temperature 0 70 C 32 158 F 0 40 C 32 104 F 0 70 C 32 158 F Auto off Around 1 minute Battery type 2 x 3Volt Button Cel...

Страница 5: ... Note Presence of bubbles will affect reading accuracy 3 Wait for the temperature reading untill it stops changing and for a stablized temperature to establish Now you can press the MODE button to switch to Salinity measurement 4 Wait 10 seconds and confirm the Salinity ppt measurement 5 Press MODE button to display Specific Gravity measurement Wait 10 seconds for the Specific Gravity before readi...

Страница 6: ...about 15 seconds or until it display shows C A L flashing 7 In a while display will show 30ppt and return to normal measuring mode 8 Calibration is completed 9 If display show 31 32 or any other values repeat the calibration Note Never perform calibration if unit is not dip into 30ppt solution as this will cause inaccuracy to the unit If reading is wrong repeat this calibration procedure 6 Tempera...

Страница 7: ... polarity are placed in direction positive sign face up as shown below 3 Switch on power to confirm whether the batteries were place correctly replace the cover 8 Troubleshooting Status Cause Remedy Low battery Worn out batteries Replace all batteries LCD display becomes dim Or stop working Wrong battery placement Check all batteries are placed correctly accordingly Contamination of sensors Wash s...

Страница 8: ...strument If repairs or adjustments are required please return the defective product freight prepaid Instrument within warranty will be repaired at no charge Make sure that the product is properly packed and insured against possible damage or loss in shipment Purchase invoice MUST be accompanied in returned product or else warranty is considered void Please obtain authorization from Trans Instrumen...