18 

 

18-HD64D1-1

Standard

 Outdoor Unit Type

None

Cooling Only

Heat Pump

 Outdoor Unit Stages

1

2

 Compressor Type

Single Compressor

Two Stage

Two Compressor

Two Stage

 Indoor Unit Type

Electric

Gas/Oil

Hydronic

 Indoor Unit Heat Stages

None

1

2

3

Modulating

 Indoor Unit Blower Type

Variable Speed

Non Variable Speed

Advanced

Equipment

      Compressor Cooling Cycles Per Hour

2

3

4

5

6

      1st Stage Compressor Heating Cycles Per Hour

2

3

4

5

6

      2nd Stage Compressor Heating Cycles Per Hour

2

3

4

5

6

      Compressor Heating Cycles Per Hour

2

3

4

5

6

      1st Stage Compressor Cooling Cycles Per Hour

2

3

4

5

6

      2nd Stage Compressor Cooling Cycles Per Hour

2

3

4

5

6

      Compressor Minimum On Time - Minutes

3

      1st Stage Compressor Minimum On Time - Minutes

3

      2nd Stage Compressor Minimum On Time - Minutes

3

      Indoor Heater Cycles Per Hour

2

3

4

5

6

      1st Stage Indoor Heater Cycles Per Hour

2

3

4

5

6

      2nd Stage Indoor Heater Cycles Per Hour

2

3

4

5

6

      3rd Stage Indoor Heater Cycles Per Hour

2

3

4

5

6

      Indoor Heater Minimum On Time - Minutes

1

      1st Stage Indoor Heater Minimum On Time - Minutes

1

      2nd Stage Indoor Heater Minimum On Time - Minutes

1

      3rd Stage Indoor Heater Minimum On Time - Minutes

1

Sensors

      Select Outdoor Temperature Sensor

None

Sensor Wired to 
Comfort Control

CLII/ AccuLink     

Outdoor Sensor

Sensor Wired to 

Relay Panel

      Calibrate Outdoor Temperature Sensor - Degrees

+/- 5 increments

      Calibrate Indoor Temperature Sensor - Degrees

Zone x +/- 5 

increments

      Calibrate RH sensor

Zone x +/- 5 

increments

Accessories

      Filtration Type Installed

Comm Air Cleaner 

Discovered

Air Cleaner

Media Filter

      Number of Air Cleaners Installed

1

2

      Humidifier Installed

Yes

No

      Humidifier Type 

Steam

Bypass/Powered

      Humidifier Control

RH Control

Frost Control

      Humidifier Control Option

Humidify with    

Active Heat Call

Humidify without 

Active Heat Call

      UV Light Installed

None

Yes

      ERV Installed

None

Yes

Comfort

      Enable Dehumidification

Disable

Enable

      Dehumidification Overcooling Limit - Degrees

0

1

2

3

      Control Response Rate

Normal

Fast

      Aggressive Recovery > 2° Setpoint Change

Disable

Enable

      Heating Aggressive Recovery 

Disable

      Heating Aggressive Recovery - Outdoor Temperature

0 to 70

Section 8. Installer Setup Parameters*

*Each 

Bold heading below corresponds to a menu in the Installer Setup.  All possible options are shown for the menu 

and each submenu.  Selections shown in any particular system will be dependent on system type and configuration.

Содержание TZONE950AC52ZA

Страница 1: ...formation is intended for use by individuals possess ing adequate backgrounds of electrical and mechanical experience Any attempt to repair a central air conditioning product may result in personal in...

Страница 2: ...F resolution Heating Setpoint Temperature Range 55 F to 90 F 1 F resolution Indoor Temperature Display Range 20 F to 119 F Outdoor Temperature Display Range 31 F to 119 F Indoor Humidity Display Rang...

Страница 3: ...50AC52ZA Outdoor Unit Indoor Unit Relay Panel BAY24VRPAC52DA Relay Panel Outdoor Unit Indoor Unit Communicating System 24V System Wired Remote Outdoor Sensor BAYSEN01ATEMPA Wired Remote Sensor ZZSENSA...

Страница 4: ...Panel BAY24VRPAC52DA Relay Panel Outdoor Unit Indoor Unit 24V System Wired Remote Outdoor Sensor BAYSEN01ATEMPA Wired Remote Outdoor Sensor BAYSEN01ATEMPA Wired Remote Sensor ZZSENSAL0400AA Optional 2...

Страница 5: ...ount the thermostat in areas where electromagnetic emissions from other devices appliances or wiring can interfere with the thermostat s communication i e wireless phones security systems wire less in...

Страница 6: ...wall Do not overtighten screws to avoid damaging the sub base 1 Press tip of SnapSkru an chor into drywall using 2 Phillips screwdriver or screw gun Drive anchor clockwise into drywall until anchor st...

Страница 7: ...ed cable is not typically required Keep this wiring at least one foot away from large inductive loads such as Electronic Air Cleaners motors line starters lighting bal lasts and large distribution pan...

Страница 8: ...wn Blue Blue Thermostat Relay Panel Red Brown Blue B D R B D R Indoor Unit Communicating Indoor Unit Communicating Outdoor Unit Communicating System Communicating Indoor with Non Communicating Outdoor...

Страница 9: ...n displays default temperature set tings and parameters Pressing a button will display additional information or a new menu screen Help Screens contain a Help button which provides additional informat...

Страница 10: ...u Service Technician Access Proceed Installer Setup NOTE Press and hold the Technician Access button for 5 seconds to enter the Installer Setup screen NOTE See Section 8 for a complete list of menus a...

Страница 11: ...ation Example Press the Comfort button to enable or disable comfort settings such as dehumidification at right Installer Setup Menu Advanced 11B Standard Pressing the Standard button allows manual sel...

Страница 12: ...ings resets the Advanced Settings which were configured in the Installer Menu settings such as system lockouts accessories air flow and comfort options Installer Setup Menu Restore Equipment Defaults...

Страница 13: ...the icon button in the top right corner of the screen will recall the alert to the home screen All alerts will remain until resolved Critical Alert indicates the loss of heating or cooling operation O...

Страница 14: ...en the alert happened the severity level of the alert as well as a problem description and possible causes to assist with troubleshooting Up to the last 30 days are displayed Dual Fuel Options The cha...

Страница 15: ...nt error plus integral time away from setpoint error is used to calculate load value Lockouts System lockouts will disable a certain function of the system under specific outdoor temperatures Compress...

Страница 16: ...her direction from setpoint and access to the weather but cannot change the mode or any customized settings Setpoint Dead Band This sets the temperature band between heating and cooling setpoints whil...

Страница 17: ...g is displayed but no warm or cool air is coming from the registers 1 There is a fan delay as the heating or cooling equipment turns on 2 Equipment is not working properly 1 Wait a minute for blower d...

Страница 18: ...On Time Minutes 1 3rd Stage Indoor Heater Minimum On Time Minutes 1 Sensors Select Outdoor Temperature Sensor None Sensor Wired to Comfort Control CLII AccuLink Outdoor Sensor Sensor Wired to Relay Pa...

Страница 19: ...ydronic Heat Blower On Delay No Delay 30 60 Hydronic Heat Blower Off Delay No Delay 30 60 90 Compressor Low Stage Air Flow Cooling 35 60 55 80 Compressor Low Stage Air Flow Compressor Heating 35 60 55...

Страница 20: ...continuous product and product data improve ment and it reserves the right to change design and specifications without notice Representative only illustrations included in this document 6200 Troup Hi...

Отзывы: