Trane TCONT203AS42MA Скачать руководство пользователя страница 8

Installation and User Guide

Pub. No. 18HD50D1-1A-EN    12/2018    

Part No. 37-7768003 

NOTES:

1) Wire third party condensate overflow 

switches between Y of the thermostat 

and Y1 of the airflow control board

2) X2 is required to energize aux heat 

during defrost

1 or 2 Stage Heat/Cool Package with Variable Speed Blower

Indoor Unit

Thermostat

Rc

Rh

O/B

Y

G

W/E

C

L

Y2

W2

R

Y1

G

W1

B

Y2

W2

W2

BK

NOTES:

1) Wire third party condensate overflow 

switches between Y of the thermostat 

and Y1 of the airflow control board

2) X2 is required to energize aux heat 

during defrost

1 or 2 Stage Heat Pump Package with Variable Speed Blower

Indoor Unit

Thermostat

Rc

Rh

O/B

Y

G

W/E

C

L

Y2

W2

R

Y1

G

W1

B

Y2

W2

W2/X2

O/B

Содержание TCONT203AS42MA

Страница 1: ...his Document is customer property and is to remain with this unit These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with the i...

Страница 2: ...ICE This product does not contain mercury However this product may replace a product that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch...

Страница 3: ...transformer is adequately sized NOTE Use 18 gauge color coded thermostat cable for proper wiring Shielded cable is not typically required Keep this wiring at least one foot away from large inductive l...

Страница 4: ...ram 7 Push excess wire into wall and plug hole with a fire resistant material such as fiberglass insulation to prevent drafts from affecting thermostat operation 8 Two AA alkaline batteries are includ...

Страница 5: ...Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R R O O Y1 G W1 B Y0 Y2 W2 W2 W2 W3 W2 BK B X2 Y Y1 Y2 NOTES 1 Y1 and Y0 connections must be made as shown for freeze protection and internall...

Страница 6: ...required to energize aux heat during defrost Cooling with GAF2 S Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R W1 B B Y NOTES 1 Wire third party condensate overflow switches betwe...

Страница 7: ...or 2 Stage Heat Pump with S9V2 Furnace Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R R O O Y1 G W1 B Y2 W2 W2 W2 W3 W2 BK B X2 Y2 Y Y1 NOTES 1 Wire third party condensate overflow...

Страница 8: ...rost 1 or 2 Stage Heat Cool Package with Variable Speed Blower Indoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R Y1 G W1 B Y2 W2 W2 BK NOTES 1 Wire third party condensate overflow switches between...

Страница 9: ...e aux heat during defrost Heat Pump Package Unit with Non Variable Speed Blower Indoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R Y1 G W1 B Y2 W2 W2 X2 O B NOTES 1 Wire third party condensate overf...

Страница 10: ...2 Stage Cooling with TEM 6 or Variable Speed Gas Furnace Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R R Y2 Y1 G W1 B W2 W2 W2 W3 W2 BK B Y2 Y Y1 NOTES 1 Wire third party condensat...

Страница 11: ...e aux heat during defrost 2 Stage Heat Pump with GAM5B Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R O G W1 B W3 W2 W2 B X2 Y Y1 R Y2 NOTES 1 Wire third party condensate overflow s...

Страница 12: ...Pump with GAT2 GAM2 TEM3 TEM4 Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W E C L Y2 W2 R O G W B B X2 Y Y1 R W2 W2 NOTES 1 Wire third party conden sate overflow switches between Y of the thermo...

Страница 13: ...hermostat G NOTES 1 Wire third party condensate overflow switches between Y of the thermostat and Y1 of the airflow control board 2 X2 is required to energize aux heat during defrost Cooling with GAF2...

Страница 14: ...FF OFF 10 TO 100 30 CR Heat Cycle Rate how often the heat will turn on MEd SLO slow MEd medium FAS fast 32 CR Aux Cycle Rate how often the auxiliary heat will turn on MEd SLO slow MEd medium FAS fast...

Страница 15: ...heat should begin to operate and the thermostat will indicate Heat On Aux 4 Press to adjust thermostat setting 1 below room temperature The heating system should stop operating and the Heat On icon w...

Страница 16: ...o the home screen 5 Raises Temperature Setting 12 Thermostat is protecting the equipment from short cycling 5 minute delay 6 Access Menu Options 13 Indicates that the system is running in Cool Heat or...

Страница 17: ...a minimum run time for the fan regardless of whether the heating and cooling equipment is running When in use FAn will appear on the home screen momentarily replacing the displayed time Choosing a se...

Страница 18: ...period 6 Continue to press Next to advance through all periods P1 Wake P2 Leave P3 Return P4 Sleep for all days of the week Note Press Back to return to the previous setting Once all days of the week...

Страница 19: ...thermostat to Cool and lower the set point below the room temperature There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock out option is selected in t...

Страница 20: ...rer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice Representative only illustrations included in this docu...

Отзывы: