Trane XR103 Non-Programmable Thermostat

Pub. No. 18HD55D1-1C-EN    09/2020    

Part No. 37-7790003 

 3

SPECIFICATION

DESCRIPTION

Product Models

TCONT103

Product

XR 103

Size

3-7/8” x 5-1/2” x 1-3/16” (HxWxD)

Configurations

Heat Pump 

 

Maximum Number of Stages

2H/1C

Operating Temperature

32°F to 105°F (0 to +41°C) / 90% RH Non Condensing

Shipping Temperature Range

-40 to 150°F (-40 to +65°C)

Input Power (DC)

Two 1.5V AAA Alkaline

Input Power (AC)

20-30 VAC, NEC Class ll, 50/60 HZ

Terminal Load

1.0A terminal/1.5A combined

Wire Usage

18 AWG

System Modes

Heating, Cooling, Off, Emergency Heat

Fan Modes

Auto, On 

Indoor Temperature Display Range

45°F to 90°F

*On every application, 24VAC loads should be reviewed to be sure the indoor unit control power transformer is adequately sized.

NOTE: 

Use 18-gauge color-coded thermostat cable for proper wiring. Shielded cable is not typically required. 

Keep this wiring at least one foot away from large inductive loads such as Electronic Air Cleaners, motors, line starters, lighting ballasts and 
large distribution panels. Failure to follow these wiring practices may introduce electrical interference (noise) which can cause erratic system 
operation. 
All unused thermostat wire to be grounded at indoor unit chassis ground only. Shielded cable may be required if the above wiring guidelines 
cannot be met. Ground only one end of the shield to the system chassis. 

2.  Product Specifications

3.  General Information

3.1  Overview

The 103 is a non-programmable HP 2H/1C thermostat with 
a digital display 

for use with HP applications only.

 

3.2  Contents

— 1-Thermostat
—  2-Phillips slotted head mounting screws
—  2-Nylon Drywall Anchors
—  1-Installation Guide / User Guide

4.  Installation

4.1  Location

The

 

103

 

is designed for installation in climate controlled living 

spaces. Place the unit in a central location with good circulation.
For proper temperature sensing, avoid exposing the

 

103 to heat 

radiated from lamps, sun light, fireplaces or any other radiant heat 
source.
Avoid locations close to windows, behind doors or alcoves with 
poor air circulation, adjoining outside walls, or doors that lead to 
the outside.
Select a location that prevents the 103 from being directly exposed 
to air currents from supply registers or ceiling fans.
Mount the Control on a section of interior wall that does not 
contain hot or cold water pipes or duct work.

FIGURE 1. PLACEMENT OF THE 103 

Incorrect
Placement

Ceiling Fan

Natural heat

dissipation

from the 

Thermostat

Onboard

Thermistor

5 FEET

Optimum
Zone

2 FEET

Correct
Placement

Heat from the screen may be trapped 

within the body of the Control by an 

external top-down airflow source, such 

as a ceiling fan.

The onboard thermistor may be biased 

by this heat causing the displayed 

indoor temperature to be elevated.

4.2  Mounting / Installation

 

Follow these steps to mount the

 

103

 

Control to the wall.

1. 

Turn OFF all power to heating and cooling equipment.

2. 

If an existing thermostat is being replaced:
a.  Record color and terminal marking of each wire.
b.  Disconnect the wires from the existing thermostat 

being careful not to allow them to fall back into the wall.

c.  Remove the existing thermostat from the wall.

Содержание TCONT103

Страница 1: ...NT This Document is customer property and is to remain with this unit These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with t...

Страница 2: ...he compressor oil heaters have been operational for six hours and the system has not been operational for at least five minutes ATTENTION MERCURY NOTICE This product does not contain mercury However t...

Страница 3: ...oduct Specifications 3 General Information 3 1 Overview The 103 is a non programmable HP 2H 1C thermostat with a digital display for use with HP applications only 3 2 Contents 1 Thermostat 2 Phillips...

Страница 4: ...cy or auxiliary heat system requires that the thermostat energize the fan circuit do not cut jumper W906 If you are unsure of your application contact a qualified service person F or C Selection The f...

Страница 5: ...heat during defrost Heat Pump with TAM Series 24V Indoor Unit Outdoor Unit Thermostat R O B Y G E C L W2 R R O O Y1 G W1 B Y0 Y2 W2 W2 W2 W3 W2 BK B X2 Y Y1 NOTES 1 Wire third party condensate overfl...

Страница 6: ...it Outdoor Unit Thermostat R O B Y G E C L W2 R R O Y G W1 B W2 W2 B X2 Y NOTES 1 Wire third party condensate overflow switches between Y of the thermostat and Y1 of the airflow control board 2 X2 is...

Страница 7: ...eat during defrost Heat Pump with GAT2 GAM2 TEM3 TEM4 Indoor Unit Outdoor Unit Thermostat R O B Y G E C L W2 R O G W B B X2 Y Y1 R W2 W3 NOTES 1 Wire third party condensate overflow switches between Y...

Страница 8: ...en 2nd stage heat Aux or Emergency is energized Snowflake icon is displayed non flashing when the SYSTEM switch is in theCOOLposition SnowflakeandFlameiconsaredisplayed flashing if the thermostat is i...

Страница 9: ...on high speed followed by cold air circulation 3 Press to adjust temperature setting above room temperature The cooling system should stop operating 6 5 Configuration Menu The configuration menu allo...

Страница 10: ...ace manufacturer or a service person to verify the heating is operating correctly No Cool 1 System Switch not set to Cool 2 Loose connection to thermostat or system 3 Cooling System requires service o...

Страница 11: ...Pub No 18HD55D1 1C EN 09 2020 Part No 37 7790003 11 NOTES...

Страница 12: ...plications For more information please visit trane com or tranetechnologies com Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without...

Отзывы: