Gas Furnace - Multistage

 Mechanical Settings

a.  Press the 

MENU button twice.

b.  Press and hold the two inner buttons for 3 seconds to view 

Installer Settings.

c.  Scroll down to 

System Settings and press the Select button.

d.  Scroll to 

Mechanical Settings (it is the first option), then press the 

Select button.

e.  Scroll down to 

2nd Stage Heat.

f.  Press the 

+ button to change the setting to Y for Yes.

g.  If your system also has 2nd stage cooling, scroll down to 

2nd Stage Cool and press the + button to change the setting to Y 
for Yes. 

h.  Press the 

Done button 4 times and go to step 19.

18A

Electric Furnace

 Mechanical Settings

a.  Press the 

MENU button twice.

b.  Press and hold the two inner buttons for 3 seconds to view 

Installer Settings.

c.  Scroll down to 

System Settings and press the Select button.

d.  Scroll to 

Mechanical Settings (it is the first option), then press the 

Select button.

e.  Scroll down to 

Fan Type.

f.  Press the 

+ button to change the setting Electric

•  If Single Stage System, press 

Done 4 times and go to step 19.

•  If Multistage System, continue with steps “g” through “j”.

g.  Scroll down to 

2nd Stage Heat.

h.  Press the 

+ button to change the setting to Y for Yes. 

i.  If your system also has 2nd stage cooling, scroll down to 

2nd Stage Cool and press the + button to change the setting to Y 
for Yes. 

j.  Press the 

Done button 4 times and go to step 19.

18B

18C

Heat Pump

 Mechanical Settings

a.  Press the 

MENU button twice.

b.  Press and hold the two inner buttons for 3 seconds to view 

Installer Settings.

c.  Scroll down to 

System Settings and press the Select button.

d.  Scroll to 

Mechanical Settings (it is the first option), then press the 

Select button.

e.  Scroll to system 

Type.

f.  Press the 

button to change the setting to Heat Pump

g.  Scroll down to 

Fan Type.

h.  Press the 

+ button to change the setting Electric.

i.  If Coleman, Rheem, or Rudd brand heat pump, scroll to 

C/O Type 

and change to 

With Heat.

•  If Single Stage System, press 

Done 4 times and go to step 19.

•  If Multistage System, continue with steps “j” through “n”.

j.  Scroll down to 

2nd Stage Heat.

k.  Press the 

+ button to change the setting to Y for Yes. 

l.  Scroll down to 

2nd Stage Cool.

m.  Press the 

+ button to change the setting to Y for Yes. 

n.  Press the 

Done button 4 times and go to step 19.

Menu

button

MENU   MODE     FAN       RUN

75

76 H
74 C

11:15 PM 

Two inner

buttons

Scroll

up

Scroll

down

Set button

Set button

+ button

Done

Mechanical Settings

Select

Type        Heatpump
Fan Type          Elec
C/O Type      w/Cool
2nd Stage Heat    N

Содержание Schlage LiNK TZEMT400BB32MAA

Страница 1: ...patible with the following system types Radiant floor systems Wall heating systems Also the Trane Thermostat is not compatible with dual fuel systems gas furnace heat pump combined without adding a sp...

Страница 2: ...the 24 VAC common terminal identified with the letter C X B or COM This terminal may already have a wire connected to it but it may not be a wire that goes to the thermostat 24 VAC common terminal C X...

Страница 3: ...he label write down the terminal names and wire colors for later reference Y Y G W1 C R G R c R C Wire colors and letters may vary W 1 4 B C E F G O L Y1 Y2 Rc R Rh R X2 T W1 W W2 W3 X Y P516 001 Rev...

Страница 4: ...Gas Furnace Multi Stage W2 label multi stage heating Y2 label multi stage cooling Electric Furnace Heat Pump Electric Furnace Single Stage Electric Furnace Multi Stage W2 label multi stage heating Y2...

Страница 5: ...the Schlage Bridge 8 Mark two mounting holes using new wall plate a Pull wires through hole in center of wall plate b Locate the new wall plate over existing opening c Mark two holes with pencil d Us...

Страница 6: ...x C X R RC VR V RH E X2 W W1 W2 Y AUX O R G F Y Y1 Y2 Connects to New Thermostat Terminals 24COM 24RC 24RH W1 W2 O B G Y1 Y2 Connect two wires to the W1 terminal If your existing thermostat has a V or...

Страница 7: ...ay should turn on and begin displaying information If the thermostat display does not come on go back through the installation steps and look for problems Pay special attention to steps 3 3a and 11 14...

Страница 8: ...t option then press the Select button c Scroll up or down to Set Clock it is the first option then press the Select button Done Select User Settings Set Clock Filter Service Maint Service Screen Timeo...

Страница 9: ...on to change the setting to Y for Yes i If your system also has 2nd stage cooling scroll down to 2nd Stage Cool and press the button to change the setting to Y for Yes j Press the Done button 4 times...

Страница 10: ...ct wires were connected to the wall plate and that each wire is securely attached to the appropriate terminal Also go back and verify that you have set up the Mechanical Settings to match your System...

Страница 11: ...s button on the Schlage Bridge c Press the MENU button on the thermostat d Scroll down to Z Wave Install and press the Select button e Press the Yes button to enroll the thermostat f Observe the light...

Страница 12: ...on Just Purchased A Schlage LiNK System For more information about the Schlage LiNK system visit www link schlage com Completing the setup a Remove the battery from the Schlage Bridge b Plug the Ether...

Отзывы: