Introduction

Warnings, Cautions, and Notices

Safety advisories appear throughout this manual as required.Your personal safety and the proper
operation of this machine depend upon the strict observance of these precautions.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.

CAUTION

s

Indicates a potentially hazardous situation which, if not avoided, could result in
minor or moderate injury. It could also be used to alert against unsafe practices.

NOTICE

Indicates a situation that could result in equipment or property-damage only
accidents.

WARNING

Proper Field Wiring and Grounding Required!

Failure to follow code could result in death or serious injury. All field wiring MUST be
performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE
and ELECTROCUTION hazards.To avoid these hazards, you MUST follow requirements for field
wiring installation and grounding as described in NEC and your local/state electrical codes.
Failure to follow code could result in death or serious injury.

WARNING

Personal Protective Equipment (PPE) Required!

Installing/servicing this unit could result in exposure to electrical, mechanical and chemical
hazards.

Before installing/servicing this unit, technicians MUST put on all PPE required for the work
being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard
hat/bump cap, fall protection, electrical PPE and arc flash clothing). ALWAYS refer to
appropriate Material Safety Data Sheets (MSDS)/Safety Data Sheets (SDS) and OSHA
guidelines for proper PPE.

When working with or around hazardous chemicals, ALWAYS refer to the appropriate MSDS/

SDS and OSHA/GHS (Global Harmonized System of Classification and Labeling of
Chemicals) guidelines for information on allowable personal exposure levels, proper
respiratory protection and handling instructions.

If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPE
in accordance with OSHA, NFPA 70E, or other country-specific requirements for arc flash
protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING,
DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC
FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED
FOR INTENDED VOLTAGE.

Failure to follow instructions could result in death or serious injury.

Содержание PM014

Страница 1: ...dge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the litera...

Страница 2: ...de could result in death or serious injury WARNING Personal Protective Equipment PPE Required Installing servicing this unit could result in exposure to electrical mechanical and chemical hazards Befo...

Страница 3: ...ication at any time and to make changes to its content without obligation to notify any person of such revision or change Trademarks All trademarks referenced in this document are the trademarks of th...

Страница 4: ...Recommended Configuration 10 Installing the Power Supply Module 11 Repositioning or Removing the Power Supply Module 12 Power and Field Wiring 13 Installing Power Input Wire 13 Grounding the Power Su...

Страница 5: ...dule and other equipment The PM014 uses a full wave rectifier It is designed to safely share power with a device that uses half wave rectification within the transformer limits The power supply module...

Страница 6: ...es 24 24 VAC VAC XFMR XFMR OUT OUT 24 24 VAC VAC 2 4 in 6 14 cm 2 4 in 6 1 cm 1 8 in 4 5 cm 4 0 in 10 2 cm 2 4 in 6 1 cm 1 2 in 3 1 cm 0 6 in 1 5 cm 2 0 in 5 0 cm 2 0 in 5 0 cm PM014 24 VAC XFMR OUT 2...

Страница 7: ...Codes and standards Listing Description UL C UL IEC60950 1 UL recognized under Information Technology Equipment Safety Part 1 General Requirements UL916 Open listing CE Conformity The European Union...

Страница 8: ...PM014 Specifications Enclosure IP20 NEMA 1 DIN rail DIN 50022 35 mm x 7 5 mm Environmental Parameters Storage temperature 67 F 55 C minimum 203 F 95 C maximum Operating temperature 40 F 40 C minimum...

Страница 9: ...as outlined in Table 3 p 9 Do not mount the power supply module on a flat surface such as on a floor or on top of a table Mount in an upright position with the front facing outward Transformer Conside...

Страница 10: ...ustrated in Figure 2 Place DIN rail end stops at each end of the configuration to prevent shifting of modules Figure 2 Correct horizontal mounting PM014 24 VAC XFMR OUT 24 VAC DIN rail end stop DIN ra...

Страница 11: ...rm the lockout tagout procedures for line voltage power to the electrical cabinet 2 Do not use excessive force Excessive force could cause equipment damage 3 Hook the power supply module DIN rail groo...

Страница 12: ...ver to disengage the clip Do not use excessive force Excessive force could cause equipment damage 3 While holding tension on the DIN rail latch lift the module upward to remove or reposition 4 If repo...

Страница 13: ...verify that the wire cannot be easily pulled out by lightly tugging on each wire For reference the screw terminals should be tightened to 0 5 to 0 6 N m 71 85 Ozf in 4 4 5 3 Lbf in Table 4 Recommende...

Страница 14: ...onnection if daisy chaining unit control modules to the power supply module The current drawn through this connection should not exceed 3 Aac Figure 6 Grounding the Power Supply Module 24 VAC 24 VAC O...

Страница 15: ...wer supplies Recommended method for separating the IMC bus Note This method preserves the power supply module warranty 3 Perform lockout tagout procedures for line voltage power to the cabinet 4 Using...

Страница 16: ...start up the power supply module 1 Ensure that input voltage is 24 Vac 2 Remove the lockout tagout from line voltage power to the electrical cabinet 3 Apply power Note Initially the power supply modul...

Страница 17: ...recommendations reveal no problems you may need to replace the power supply module Remove the power supply as instructed in Repositioning or Removing the Power Supply Module p 12 Table 6 Status LED A...

Страница 18: ...ge across the 24 Vdc output termination Compare to expected value based on request from PM014 specification see Table 2 p 8 Figure 10 PM014 24 Vac Output AC measurement VAC ADC VDC IMC IMC IMC 24 DC I...