Trane Odyssey  TTA2014DC Скачать руководство пользователя страница 21

SS-SVX001A-EN

21

Installation

Refrigerant Piping Guidelines

Figure 13.

Allowable elevation difference: TTA

above

indoor unit

Contact manufacturer for review

Figure 14.

Allowable elevation difference: TTA or TWA

below

indoor unit

Acceptable liquid-riser height 
based on total liquid-line length
(below indoor unit)

Contact manufacturer for review

N

No

otte

e:: Route refrigerant piping for minimum linear length, minimum number of bends and fittings.

IIm

mp

po

orrtta

an

ntt:: Read Application Guide SS-APG008*–EN

thoroughly before installing this unit.

Содержание Odyssey TTA2014DC

Страница 1: ...rking on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment March 2020 S SS S S SV VX X0 00 01 1A A E EN N Installation Oper...

Страница 2: ...r p pr ro op pe er r P PP PE E f fo or r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i in...

Страница 3: ...RN NI IN NG G E Ex xp pl lo os si io on n H Ha az za ar rd d F Fa ai il lu ur re e t to o f fo ol ll lo ow w i in ns st tr ru uc ct ti io on ns s b be el lo ow w c co ou ul ld d r re es su ul lt t i i...

Страница 4: ...Lines 24 Refrigerant Charging Procedure 25 Charging Levels 26 Liquid Charging 27 Electrical Wiring 27 Unit Power Supply 28 Low Voltage Wiring 28 Symbio Controls 28 Field Wiring 29 Refrigerant Circuit...

Страница 5: ...K 380 Vac 3 PH 60Hz Digit 9 Refrigeration Circuit Stage A 1 Compressor 1 Line 1 Stage Single C 2 Compressors 1 Line 2 Stage Manifold D 2 Compressors 2 Line 2 Stage Dual Digit 10 Major Design Sequence...

Страница 6: ...ould be performed in the sequence that they appear in this manual Do not destroy or remove the manual from the unit The manual should remain weather protected with the unit until all installation proc...

Страница 7: ...lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y a an nd d e eq qu ui ip pm me en nt t o or r p pr ro op pe er rt ty y o on nl ly y d da am ma ag ge e T Te es st t l li if f...

Страница 8: ...rmine for certain that the structure is strong enough to support the unit and any required accessories see Weights p 19 The unit should be elevated on a level field fabricated four inch steel or wood...

Страница 9: ...unit power wiring with disconnect to proper terminals in the unit control enclosure Installed system indoor thermostat or zone sensor Installed system low voltage interconnecting wiring to proper ter...

Страница 10: ...39 125 993 8 42 125 1070 36 914 4 TTA101 120 R 410A and TTA1202 A R 22 39 125 993 8 52 125 1324 40 1016 TTA126 150 R 410A 45 125 1146 1 52 125 1324 40 1016 TTA156 180 201 240 R 410A and TTA1802 D 2402...

Страница 11: ...RANCE 48 1219 2 SEE NOTE 2 FOR CLEARANCE SEE NOTE 1 REFRIGERANT GUAGE ACCESS CONTROL WIRING OPTIONAL 7 16 11 11 DIA ISOLATOR MOUNTING HOLES OUTSIDE HOLES 4 PLACES BOTTOM OF UNIT SEE NOTE 4 HAIL GUARD...

Страница 12: ...BOTTOM OF UNIT SEE NOTE 4 HAIL GUARD OPTIONAL SEE NOTE 3 NOTES 1 ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY 2 MINIMUM CLEARANCE FOR PROPER OPERATION IS 36 914 4 FROM WALLS SHRUBBERY PRIVA...

Страница 13: ...P DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100 2540 MINIMUM UNIT SHOULD BE PLACED SO ROOF RUN OFF WATER OR FALLING SNOW FROM ROOF DOES NOT POUR FALL DIRECTLY ON UNIT 4 OUTDOOR AIR TEMPERATURE SENSOR...

Страница 14: ...CE FOR PROPER OPERATION IS 36 914 4 FROM WALLS SHRUBBERY PRIVACY FENCES ETC MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72 1828 8 RECOMMENDED SERVICE CLEARANCE 48 1219 2 3 TOP DISCHARGE AREA SHOULD BE...

Страница 15: ...914 4 FROM WALLS SHRUBBERY PRIVACY FENCES ETC MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72 1828 8 RECOMMENDED SERVICE CLEARANCE 48 1219 2 2 TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100 2540 MIN...

Страница 16: ...3 DETAIL A SERVICE PANEL SERVICE CLEARANCE 48 1219 2 SEE NOTE 1 FOR CLEARANCE HAIL GUARD OPTIONAL HAIL GUARD OPTIONAL LINE VOLTAGE CONTROL WIRING SUCTION LINES WITHOUT HAIL GUARD UNIT COIL HAIL GUARD...

Страница 17: ...ARANCE HAIL GUARD OPTIONAL HAIL GUARD OPTIONAL LINE VOLTAGE CONTROL WIRING SUCTION LINES WITHOUT HAIL GUARD UNIT COIL HAIL GUARD OPTIONAL LIQUID LINES SERVICE PANEL SIDE BOTTOM OF UNIT 7 16 11 1 DIA I...

Страница 18: ...OM OF UNIT SERVICE PANEL SIDE LIQUID LINE REFRIGERANT GAUGE ACCESS SUCTION LINE LINE VOLTAGE CONTROL WIRING FRONT DETAIL A DIMENSIONAL DETAIL SEE NOTE 3 NOTES 1 MINIMUM CLEARANCE FOR PROPER OPERATION...

Страница 19: ...Table 2 TTA R 22 unit and corner weights lbs 60 Hz Tons Model No Shipping Max lbs Net Max lbs Corner Weights 1 2 3 4 7 5 TTA0902 A 328 280 73 89 51 67 10 TTA1202 A 405 329 107 84 60 77 15 TTA1802 D 7...

Страница 20: ...090 120 150 TTA060 076 101 TTA0902 A 1202 A 1 2 3 4 LIFTING HOLES BOTH SIDES SERVICE ACCESS Figure 12 TTA180 240 300 TTA156 201 251 TTA1802 D 2402 D SERVICE ACCESS SERVICE ACCESS 1 2 3 4 LIFTING HOLES...

Страница 21: ...le elevation difference TTA or TWA below indoor unit Acceptable liquid riser height based on total liquid line length below indoor unit Contact manufacturer for review N No ot te e Route refrigerant p...

Страница 22: ...es s W WA AR RN NI IN NG G E Ex xp pl lo os si io on n H Ha az za ar rd d F Fa ai il lu ur re e t to o f fo ol ll lo ow w i in ns st tr ru uc ct ti io on ns s b be el lo ow w c co ou ul ld d r re es s...

Страница 23: ...it t D Da am ma ag ge e D Do o n no ot t a ap pp pl ly y h he ea at t t to o r re em mo ov ve e s se ea al l c ca ap ps s u un nt ti il l t th he e g ga au ug ge e p po or rt t c co or re es s h ha a...

Страница 24: ...nt charging hoses from liquid and gas gauge ports 9 Leak test the entire system Using proper procedures and caution as described in the previous section repair any leaks found and repeat the leak test...

Страница 25: ...If the entire charge can t be charged into the liquid line the balance of the unit charge can be metered through a charging manifold set as liquid preferably through a schrader valve into the suction...

Страница 26: ...1204 A 13 1 N A 0 5 1 2 1 375 1 3 8 TTA1264DD w TWE1264DB 9 7 9 7 0 5 1 2 1 125 1 1 8 TTA1504 D w TWE1504 B 9 8 9 8 0 5 1 2 1 125 1 1 8 TTA1564DD w TWE1564DB 11 5 11 5 0 5 1 2 1 375 1 3 8 TTA1564DD w...

Страница 27: ...u un n c ca ap pa ac ci it to or rs s b be ef fo or re e s se er rv vi ic ci in ng g F Fo ol ll lo ow w p pr ro op pe er r l lo oc ck ko ou ut t t ta ag go ou ut t p pr ro oc ce ed du ur re es s t to...

Страница 28: ...lt t i in n e eq qu ui ip pm me en nt t d da am ma ag ge e a as s t th he e e eq qu ui ip pm me en nt t w wa as s n no ot t d de es si ig gn ne ed d o or r q qu ua al li if fi ie ed d t to o a ac cc c...

Страница 29: ...g Instructions Symbio Condenser cooling or heat pump S Constant Volume 1 Pairing A Symbio Condenser cooling or heat pump S SZVAV 2 Speed D Pairing B Symbio Condenser cooling or heat pump S Legacy CV E...

Страница 30: ...W2 T STAT Y Y2 T STAT Y X2 T STAT Y PULLDOWN T T STAT Y GND THERMOSTAT OPTIONAL REMOTE SENSOR BUILDING AUTOMATION COMMUNICATING ZONE SENSOR 7 7 6 6 5 5 4 4 3 3 2 2 1 1 1 2 3 4 4 10 11 ZONE SENSOR S1 S...

Страница 31: ...e Figure 18 p 30 a For 2 Speed Air Handler operation connect a thermostat or other zone control device to the Symbio 700 Unit Controller as shown on unit schematic b For SZVAV Operation connect a zone...

Страница 32: ...T CIRCUITS NOTE B DUAL CIRCUIT MODELS HAVE 2 REFRIGERATION CIRCUITS TXV S D COMPRESSOR LOW PRESSURE SWITCH LPCO FIELD SUPPLIED INTER CONNECTING TUBING OUTDOOR COIL INDOOR COIL EXPANSION VALVE BULB EQU...

Страница 33: ...ompressor and the outdoor fans if suction pressure drops below the Low Pressure Cut Out setting Once the suction pressure has returned to normal the compressor and outdoor fans will cycle back on High...

Страница 34: ...y W Wh he en n i it t i is s n ne ec ce es ss sa ar ry y t to o w wo or rk k w wi it th h l li iv ve e e el le ec ct tr ri ic ca al l c co om mp po on ne en nt ts s h ha av ve e a a q qu ua al li if f...

Страница 35: ...bio Service and Installation mobile application The modes shown below can be initiated Depending on the equipment configuration the controller will energize the appropriate outputs A user selected tim...

Страница 36: ...l connections are tight and that the wiring insulation is intact Inspect the condenser coils for dirt and debris If the coils appear dirty clean them With the unit operating in the cooling mode check...

Страница 37: ...le and an ECU of at least 180 with pressure no greater than 600 psi To minimize the risk of coil damage approach the cleaning of the coil with the pressure washer aimed perpendicular to the face of th...

Страница 38: ...r Superheat F at compressor Subcooling F at liquid line Dry Bulb Wet Bulb Suction Pressure Discharge Pressure Circuit 1 Circuit 2 Circuit 1 Circuit 2 C1 C2 C1 C2 Note Perform each inspection once per...

Страница 39: ...014DD TWE1014 B 436759140001 436759570001 TTA1204 D TTA1204 C 436759150001 436759580001 TTA1264DD TWE1264DB 436759160001 436759590001 TTA1504DD TWE1504DB 436759170001 436759600001 TTA1564DD TWE1564DB...

Страница 40: ...Digit 9 A 121329780001 Control Schematic Wiring Diagram for units with Dual compressor and Single Fan All TTA Units with Digit 4 6 060 072 076 090 AND Digit 9 C or D Digit 4 6 101 120 and Digit 9 C 12...

Страница 41: ...r s obligations and liabilities under this warranty are limited to furnishing F O B factory or warehouse at the warrantor designated shipping point freight allowed to Buyer s city or port of export fo...

Страница 42: ...42 SS SVX001A EN N No ot te es s...

Страница 43: ...SS SVX001A EN 43 N No ot te es s...

Страница 44: ...n please visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specificatio...

Отзывы: