ODYSSEY

TTA-R407C-EN1113

April 2016

Installation
Operation
Maintenance

Light Commercial
Split System 5-20 Tons
TTA Model 50 Hz

Single Circuit;

TTA 075 ED

TTA 100 ED

TTA 120 ED

TTA 150 ED (New)

Dual Circuit;

TTA 150 ED

TTA 180 ED

TTA 200 ED

TTA 240 ED

Manifolded Compr.;

TTA 150 ED0G

TTA 180 ED0G

TTA 200 ED0G

TTA 240 ED0G

Single Circuit (Hi-Eff)

TTA 060 FD

TTA 120 FD

TTA 240 FD

R407C

TTA-R407C-EN1113.indd   1

TTA-R407C-EN1113.indd   1

12-Sep-16   13:28:22

12-Sep-16   13:28:22

Содержание ODYSSEY TTA 060 FD

Страница 1: ...le Circuit TTA 075 ED TTA 100 ED TTA 120 ED TTA 150 ED New Dual Circuit TTA 150 ED TTA 180 ED TTA 200 ED TTA 240 ED Manifolded Compr TTA 150 ED0G TTA 180 ED0G TTA 200 ED0G TTA 240 ED0G Single Circuit...

Страница 2: ...2 Model Nomenclature 060 60 MBH F R407C Hi Eff B Mirror Design Sequence S New Design 1 Fan New comp change R Fourth Design Sequence TTA R407C EN1113 indd 2 TTA R407C EN1113 indd 2 12 Sep 16 13 28 22 1...

Страница 3: ...nt Piping Guidelines 6 Refrigerant Charging and Evacuation 8 General Data 10 Refrigerant Circuit 13 Electrical Wiring 14 Dimensional Data 19 Operation 23 Maintenance 24 Maintenance Log1 24 Trouble Sho...

Страница 4: ...the unit Check for obvious damage to the unit or packing material Inspect the unit for concealed damage before it is stored and as soon as possible after delivery Concealed damage must be reported wit...

Страница 5: ...enough space around the unit to allow unrestricted access to all service points Refer to unit dimensional data for minimum required service and free air clearances Observe the following points to ins...

Страница 6: ...ED Single Circuit TTA180ED TTA200ED and TTA240ED Dual Circuit Suction line Liquid line E Recommended line sizes TTA150ED0G TTA180ED0G TTA200ED0G TTA240FD and TTA240ED0G Manifolded Compressor TTA150ED...

Страница 7: ...ge system components and the unit nish 6 Shut off nitrogen supply 7 Shut off the manifold valve for the line that is connected to the suction line service valve Disconnect the line from the gauge port...

Страница 8: ...nt needed based on notes above Note There is holding charge of refrigerant and N2 charged from factory However when install the unit system must be vacuumed and recharged refrigerant in the eld Table...

Страница 9: ...For the additional amount using the table 4 for recommended amounts Recommended Charging Amount 4Caution R407C charge in liquid phase only Always evacuate air from the tubing before adding refrigeran...

Страница 10: ...TTA R407C EN1113 10 General Data 1 20 3 40 34 80 TTA R407C EN1113 indd 10 TTA R407C EN1113 indd 10 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 11: ...TTA R407C EN1113 11 General Data 31 45 27 08 25 20 1 20 3 40 1 20 3 40 1 20 3 40 TTA R407C EN1113 indd 11 TTA R407C EN1113 indd 11 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 12: ...5 439 428 474 462 1100 x 2200 x 1140 1050 x 2200 x 1050 1180 x 2290 x 1140 1050 x 2200 x 1050 1180 x 2290 x 1140 1050 x 2200 x 1050 1180 x 2290 x 1140 1050 x 2200 x 1050 2 200 1 750 380 3 50 1 06 2 27...

Страница 13: ...110 19 2 140 22 9 145 1 06 2 27 1 06 2 27 1 20 3 40 1 06 2 27 1 20 3 40 1 20 3 40 1 20 3 40 1 06 2 27 1 20 3 40 1 20 3 40 1 20 3 40 30 30 30 30 30 30 30 30 30 30 30 1 1 2 1 1 1 1 2 2 2 2 1 1 2 1 1 1...

Страница 14: ...lems Important All wiring must comply with applicable local and national NEC codes Type and location of disconnect switches must comply with all applicable codes disconnect switch and lock in open pos...

Страница 15: ...TTA R407C EN1113 15 Electrical Wiring TTA R407C EN1113 indd 15 TTA R407C EN1113 indd 15 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 16: ...TTA R407C EN1113 16 Electrical Wiring TTA R407C EN1113 indd 16 TTA R407C EN1113 indd 16 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 17: ...TTA R407C EN1113 17 Electrical Wiring TTA R407C EN1113 indd 17 TTA R407C EN1113 indd 17 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 18: ...TTA R407C EN1113 18 Electrical Wiring TTA R407C EN1113 indd 18 TTA R407C EN1113 indd 18 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 19: ...E TTA060FD TTA075ED TTA100 120ED TTA150ED New 950 950 950 950 1060 1060 1060 1060 778 778 778 778 888 888 888 888 1060 1060 1060 1260 1050 1050 1050 1250 A B C D E F 1 1 8 1 1 8 1 3 8 1 5 8 1 2 1 2 1...

Страница 20: ...ensional Data TTA060FD TTA060FD TTA075ED TTA100 120ED 950 950 950 1060 1060 1060 778 778 778 888 888 888 1 1 8 1 1 8 1 3 8 1 2 1 2 1 2 TTA R407C EN1113 indd 20 TTA R407C EN1113 indd 20 12 Sep 16 13 28...

Страница 21: ...TTA R407C EN1113 21 Dimensional Data TTA120FD TTA240FD 1 3 8 1 3 8 1 2 1 2 TTA120 240FD TTA150 180 200 240ED TTA R407C EN1113 indd 21 TTA R407C EN1113 indd 21 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 22: ...TTA R407C EN1113 22 TTA120FD TTA240FD 1 3 8 1 5 8 1 2 5 8 Dimensional Data TTA120 240FD TTA150 180 200 240ED0G TTA R407C EN1113 indd 22 TTA R407C EN1113 indd 22 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 23: ...ut Out s setting Internal Overload Protector IOL This device is a current thermal actuated warp switch imbedded in the compressor motor windings If will shut off the compressor if the temperature or c...

Страница 24: ...enance Log Observe indoor fan operation and correct any unusual or excessive vibration Clean blower wheels as needed Annually Cooling Season The following maintenance procedures must be performed at t...

Страница 25: ...v O l a n r e t n I r o s s e r p m o C r o t i c a p a C n u R r o t i c a p a C t r a t S y a l e r t r a t S s t c a t n o c r o t c a t n o C g n i r i W e g a t l o V w o L r e m r o f s n a r T...

Страница 26: ...sibility that serious damage will occur Finally regular maintenance ensures the maximum operating life of your equipment We would remind you that failure to respect these installation and maintenance...

Страница 27: ...TTA R407C EN1113 27 Note TTA R407C EN1113 indd 27 TTA R407C EN1113 indd 27 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 28: ...nd Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice For more information contact your local district offi...

Отзывы: