Trouble Shooting

Safety recommendations

To avoid accidents and damage, the
following recommendations should be
observed during maintenance and
service visits:
1.  The maximum allowable pressures

for system leak testing on low and
high pressure side are given in the
chapter “Installation”. Always
provide a pressure regulator.

2.  Disconnect the main supply before

any servicing on the unit.

3.  Service work on the refrigeration

system and the electrical system
should be carried out only by
qualified and experienced
personnel.

Maintenance contract

It is strongly recommended that you
sign a maintenance contract with your
local Service Agency. This contract
provides regular maintenance of your
installation by a specialist in our
equipment. Regular maintenance
ensures that any malfunction is
detected and corrected in good time
and minimizes the possibility that
serious damage will occur. Finally,
regular maintenance ensures the
maximum operating life of your
equipment. We would remind you
that failure to respect these installation
and maintenance instructions may
result in immediate cancellation of
the warranty.

Training

The equipment described in this
manual is the result of many
years of research and continuous
development. To assist you in
obtaining the best use of it, and
maintaining it in perfect operating
condition over a long period of time,
the constructor has at your disposal
a refrigeration and air conditioning
service school. The principal aim
of this is to give operators and
maintenance technicians a better
knowledge of the equipment they are
using, or that is under their charge.
Emphasis is particularly given to the
importance of periodic checks on the
unit operating parameters as well as
on preventive maintenance, which
reduces the cost of owning the unit
by avoiding serious and costly
breakdown.

TTA-R407C-EN1113.indd   26

TTA-R407C-EN1113.indd   26

12-Sep-16   13:28:23

12-Sep-16   13:28:23

Содержание ODYSSEY TTA 060 FD

Страница 1: ...le Circuit TTA 075 ED TTA 100 ED TTA 120 ED TTA 150 ED New Dual Circuit TTA 150 ED TTA 180 ED TTA 200 ED TTA 240 ED Manifolded Compr TTA 150 ED0G TTA 180 ED0G TTA 200 ED0G TTA 240 ED0G Single Circuit...

Страница 2: ...2 Model Nomenclature 060 60 MBH F R407C Hi Eff B Mirror Design Sequence S New Design 1 Fan New comp change R Fourth Design Sequence TTA R407C EN1113 indd 2 TTA R407C EN1113 indd 2 12 Sep 16 13 28 22 1...

Страница 3: ...nt Piping Guidelines 6 Refrigerant Charging and Evacuation 8 General Data 10 Refrigerant Circuit 13 Electrical Wiring 14 Dimensional Data 19 Operation 23 Maintenance 24 Maintenance Log1 24 Trouble Sho...

Страница 4: ...the unit Check for obvious damage to the unit or packing material Inspect the unit for concealed damage before it is stored and as soon as possible after delivery Concealed damage must be reported wit...

Страница 5: ...enough space around the unit to allow unrestricted access to all service points Refer to unit dimensional data for minimum required service and free air clearances Observe the following points to ins...

Страница 6: ...ED Single Circuit TTA180ED TTA200ED and TTA240ED Dual Circuit Suction line Liquid line E Recommended line sizes TTA150ED0G TTA180ED0G TTA200ED0G TTA240FD and TTA240ED0G Manifolded Compressor TTA150ED...

Страница 7: ...ge system components and the unit nish 6 Shut off nitrogen supply 7 Shut off the manifold valve for the line that is connected to the suction line service valve Disconnect the line from the gauge port...

Страница 8: ...nt needed based on notes above Note There is holding charge of refrigerant and N2 charged from factory However when install the unit system must be vacuumed and recharged refrigerant in the eld Table...

Страница 9: ...For the additional amount using the table 4 for recommended amounts Recommended Charging Amount 4Caution R407C charge in liquid phase only Always evacuate air from the tubing before adding refrigeran...

Страница 10: ...TTA R407C EN1113 10 General Data 1 20 3 40 34 80 TTA R407C EN1113 indd 10 TTA R407C EN1113 indd 10 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 11: ...TTA R407C EN1113 11 General Data 31 45 27 08 25 20 1 20 3 40 1 20 3 40 1 20 3 40 TTA R407C EN1113 indd 11 TTA R407C EN1113 indd 11 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 12: ...5 439 428 474 462 1100 x 2200 x 1140 1050 x 2200 x 1050 1180 x 2290 x 1140 1050 x 2200 x 1050 1180 x 2290 x 1140 1050 x 2200 x 1050 1180 x 2290 x 1140 1050 x 2200 x 1050 2 200 1 750 380 3 50 1 06 2 27...

Страница 13: ...110 19 2 140 22 9 145 1 06 2 27 1 06 2 27 1 20 3 40 1 06 2 27 1 20 3 40 1 20 3 40 1 20 3 40 1 06 2 27 1 20 3 40 1 20 3 40 1 20 3 40 30 30 30 30 30 30 30 30 30 30 30 1 1 2 1 1 1 1 2 2 2 2 1 1 2 1 1 1...

Страница 14: ...lems Important All wiring must comply with applicable local and national NEC codes Type and location of disconnect switches must comply with all applicable codes disconnect switch and lock in open pos...

Страница 15: ...TTA R407C EN1113 15 Electrical Wiring TTA R407C EN1113 indd 15 TTA R407C EN1113 indd 15 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 16: ...TTA R407C EN1113 16 Electrical Wiring TTA R407C EN1113 indd 16 TTA R407C EN1113 indd 16 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 17: ...TTA R407C EN1113 17 Electrical Wiring TTA R407C EN1113 indd 17 TTA R407C EN1113 indd 17 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 18: ...TTA R407C EN1113 18 Electrical Wiring TTA R407C EN1113 indd 18 TTA R407C EN1113 indd 18 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 19: ...E TTA060FD TTA075ED TTA100 120ED TTA150ED New 950 950 950 950 1060 1060 1060 1060 778 778 778 778 888 888 888 888 1060 1060 1060 1260 1050 1050 1050 1250 A B C D E F 1 1 8 1 1 8 1 3 8 1 5 8 1 2 1 2 1...

Страница 20: ...ensional Data TTA060FD TTA060FD TTA075ED TTA100 120ED 950 950 950 1060 1060 1060 778 778 778 888 888 888 1 1 8 1 1 8 1 3 8 1 2 1 2 1 2 TTA R407C EN1113 indd 20 TTA R407C EN1113 indd 20 12 Sep 16 13 28...

Страница 21: ...TTA R407C EN1113 21 Dimensional Data TTA120FD TTA240FD 1 3 8 1 3 8 1 2 1 2 TTA120 240FD TTA150 180 200 240ED TTA R407C EN1113 indd 21 TTA R407C EN1113 indd 21 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 22: ...TTA R407C EN1113 22 TTA120FD TTA240FD 1 3 8 1 5 8 1 2 5 8 Dimensional Data TTA120 240FD TTA150 180 200 240ED0G TTA R407C EN1113 indd 22 TTA R407C EN1113 indd 22 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 23: ...ut Out s setting Internal Overload Protector IOL This device is a current thermal actuated warp switch imbedded in the compressor motor windings If will shut off the compressor if the temperature or c...

Страница 24: ...enance Log Observe indoor fan operation and correct any unusual or excessive vibration Clean blower wheels as needed Annually Cooling Season The following maintenance procedures must be performed at t...

Страница 25: ...v O l a n r e t n I r o s s e r p m o C r o t i c a p a C n u R r o t i c a p a C t r a t S y a l e r t r a t S s t c a t n o c r o t c a t n o C g n i r i W e g a t l o V w o L r e m r o f s n a r T...

Страница 26: ...sibility that serious damage will occur Finally regular maintenance ensures the maximum operating life of your equipment We would remind you that failure to respect these installation and maintenance...

Страница 27: ...TTA R407C EN1113 27 Note TTA R407C EN1113 indd 27 TTA R407C EN1113 indd 27 12 Sep 16 13 28 23 12 Sep 16 13 28 23...

Страница 28: ...nd Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice For more information contact your local district offi...

Отзывы: