![Trane Odyssey Symbio BAYTFMR014 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/trane/odyssey-symbio-baytfmr014/odyssey-symbio-baytfmr014_installation-manual_1150401006.webp)
6
ACC-SVN184B-EN
Installation
Air Handler Unit Transformer
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e w
w//C
Ca
ap
pa
acciitto
orrss!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err a
an
nd
d d
diisscch
ha
arrg
ge
e
cca
ap
pa
acciitto
orrss b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss a
an
nd
d d
diisscch
ha
arrg
ge
e a
allll m
mo
otto
orr sstta
arrtt//rru
un
n
cca
ap
pa
acciitto
orrss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
nn
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. F
Fo
orr v
va
arriia
ab
blle
e
ffrre
eq
qu
ue
en
nccy
y d
drriiv
ve
ess o
orr o
otth
he
err e
en
ne
errg
gy
y sstto
orriin
ng
g
cco
om
mp
po
on
ne
en
nttss p
prro
ov
viid
de
ed
d b
by
y T
Trra
an
ne
e o
orr o
otth
he
errss,, rre
effe
err tto
o
tth
he
e a
ap
pp
prro
op
prriia
atte
e m
ma
an
nu
uffa
accttu
urre
err’’ss lliitte
erra
attu
urre
e ffo
orr
a
allllo
ow
wa
ab
blle
e w
wa
aiittiin
ng
g p
pe
erriio
od
dss ffo
orr d
diisscch
ha
arrg
ge
e o
off
cca
ap
pa
acciitto
orrss.. V
Ve
erriiffy
y w
wiitth
h a
a C
CA
AT
T IIIIII o
orr IIV
V v
vo
ollttm
me
ette
err
rra
atte
ed
d p
pe
err N
NF
FP
PA
A 7
70
0E
E tth
ha
att a
allll cca
ap
pa
acciitto
orrss h
ha
av
ve
e
d
diisscch
ha
arrg
ge
ed
d..
Figure 2. Transformer installation
Power
Harness
24 Volt harness
Transformer
Safety agency
label placement
Relay board
connection
Hinged cover
Screws
Hinged cover
Green ground
screw
Lock washer
1. Disconnect all power and lock out the unit.
2. Remove the air handler's side panel which conceals
the unit control box (the panel with the nameplate).
3. Remove and retain the 2 screws that secure the
hinged cover of the control box. See
.
4. Install the transformer using 2 screws and lock
washers (provided in Kit) on the divider panel in the
high voltage section. See
5. Of the two power wire harnesses included with the
kit, choose the one that has terminations
appropriate to the type of connections and install
the harness per unit diagram:
•
Harness with 1/4" Quick Connect terminals will
connect to the indoor fan contactor of units with
constant volume fan control.
•
Harness with stripped leads will connect to the
fuse block of unit with SZVAV / 2-speed fan
control.
Discard the unused power wire harness.
6. Connect the 24 VAC harness from the transformer
to the relay board per unit diagram. See
7. Attach ground wire in 24VAC harness to the divider
panel using the green ground screw going through
wire terminal and lock washer. See
8. Connect the harnesses to the transformer by
snapping together the in-line color coded
connectors.
9. Secure wires away from sharp edges using wire
ties (provided in kit).
10. Apply the safety agency label to the side of the
control box. See
N
No
otte
ess::
•
The 208/230V transformers are factory wired
for 230V. To convert to 208 volt power,
disconnect wire from the 230V terminal on
the primary side of the transformer and
reconnect to the 208V terminal.
•
Full wiring schematics are available through
e-Library. If access is not available, contact
your local sales office.
11. Close and secure the high voltage access panel
using the 2 screws that were previously removed.
12. Re-install the air handler's side panel.
Содержание Odyssey Symbio BAYTFMR014
Страница 7: ...ACC SVN184B EN 7 N No ot te es s...