Installation

Air Handler Unit Transformer

W

WA

AR

RN

NIIN

NG

G

H

Ha

azza

arrd

do

ou

uss V

Vo

olltta

ag

ge

e w

w//C

Ca

ap

pa

acciitto

orrss!!

F

Fa

aiillu

urre

e tto

o d

diisscco

on

nn

ne

ecctt p

po

ow

we

err a

an

nd

d d

diisscch

ha

arrg

ge

e

cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr

sse

erriio

ou

uss iin

njju

urry

y..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e

d

diisscco

on

nn

ne

eccttss a

an

nd

d d

diisscch

ha

arrg

ge

e a

allll m

mo

otto

orr sstta

arrtt//rru

un

n

cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err

llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e tth

he

e p

po

ow

we

err

cca

an

nn

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d.. F

Fo

orr v

va

arriia

ab

blle

e

ffrre

eq

qu

ue

en

nccy

y d

drriiv

ve

ess o

orr o

otth

he

err e

en

ne

errg

gy

y sstto

orriin

ng

g

cco

om

mp

po

on

ne

en

nttss p

prro

ov

viid

de

ed

d b

by

y T

Trra

an

ne

e o

orr o

otth

he

errss,, rre

effe

err tto

o

tth

he

e a

ap

pp

prro

op

prriia

atte

e m

ma

an

nu

uffa

accttu

urre

err’’ss lliitte

erra

attu

urre

e ffo

orr

a

allllo

ow

wa

ab

blle

e w

wa

aiittiin

ng

g p

pe

erriio

od

dss ffo

orr d

diisscch

ha

arrg

ge

e o

off

cca

ap

pa

acciitto

orrss.. V

Ve

erriiffy

y w

wiitth

h a

a C

CA

AT

T IIIIII o

orr IIV

V v

vo

ollttm

me

ette

err

rra

atte

ed

d p

pe

err N

NF

FP

PA

A 7

70

0E

E tth

ha

att a

allll cca

ap

pa

acciitto

orrss h

ha

av

ve

e

d

diisscch

ha

arrg

ge

ed

d..

Figure 2. Transformer installation

Power

Harness

24 Volt harness

Transformer

Safety agency

label placement

Relay board

connection

Hinged cover

Screws

Hinged cover

Green ground

screw

Lock washer

1. Disconnect all power and lock out the unit.

2. Remove the air handler's side panel which conceals

the unit control box (the panel with the nameplate).

3. Remove and retain the 2 screws that secure the

hinged cover of the control box. See

Figure 2, p. 6

.

4. Install the transformer using 2 screws and lock

washers (provided in Kit) on the divider panel in the
high voltage section. See

Figure 2, p. 6

.

5. Of the two power wire harnesses included with the

kit, choose the one that has terminations
appropriate to the type of connections and install
the harness per unit diagram:

Harness with 1/4" Quick Connect terminals will
connect to the indoor fan contactor of units with
constant volume fan control.

Harness with stripped leads will connect to the
fuse block of unit with SZVAV / 2-speed fan
control.

Discard the unused power wire harness.

6. Connect the 24 VAC harness from the transformer

to the relay board per unit diagram. See

Figure 2, p.

6

.

7. Attach ground wire in 24VAC harness to the divider

panel using the green ground screw going through
wire terminal and lock washer. See

Figure 2, p. 6

.

8. Connect the harnesses to the transformer by

snapping together the in-line color coded
connectors.

9. Secure wires away from sharp edges using wire

ties (provided in kit).

10. Apply the safety agency label to the side of the

control box. See

Figure 2, p. 6

.

N

No

otte

ess::

The 208/230V transformers are factory wired
for 230V. To convert to 208 volt power,
disconnect wire from the 230V terminal on
the primary side of the transformer and
reconnect to the 208V terminal.

Full wiring schematics are available through
e-Library. If access is not available, contact
your local sales office.

11. Close and secure the high voltage access panel

using the 2 screws that were previously removed.

12. Re-install the air handler's side panel.

Содержание Odyssey Symbio BAYTFMR014

Страница 1: ...rve all precautions in the literature and on the tags stickers and labels that are attached to the equipment March 2022 A AC CC C S SV VN N1 18 84 4B B E EN N Installation Guide Transformer Odyssey Sp...

Страница 2: ...r r p pr ro op pe er r P PP PE E f fo or r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i i...

Страница 3: ...eg gu ul la at ti io on ns s a ar re e m mo or re e s st tr ri in ng ge en nt t t th ha an n t th he es se e p po ol li ic ci ie es s t th ho os se e r re eg gu ul la at ti io on ns s s su up pe er r...

Страница 4: ...power the 24 Vac loads in the air handler thereby reducing the load on the 24 Vac transformer in the condensing unit Table 1 Transformer kits Transformer Voltage Unit s with unit model number digit 1...

Страница 5: ...2 Screw 10 32 X 50 Sht Mtl 11 1 Screw 10 32 X 50 Sht Mtl Green Ground 12 3 Lockwasher 10 Depending on the kit used quantity of washers may vary 1 2 3 4 6 7 8 9 10 11 12 5 Inspection Remove the conten...

Страница 6: ...e d di is sc ch ha ar rg ge ed d Figure 2 Transformer installation Power Harness 24 Volt harness Transformer Safety agency label placement Relay board connection Hinged cover Screws Hinged cover Green...

Страница 7: ...ACC SVN184B EN 7 N No ot te es s...

Страница 8: ...ease visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications w...

Отзывы: