8
RT-SVX24Q-EN
DIGIT 18 — Exhaust/Return Fan
Motor Selection
0
= None
D
= 7.5 Hp
E
= 10 Hp
F
= 15 Hp
G
= 20 Hp
H
= 25 Hp
J
= 30 Hp
K
= 40 Hp
L
= 50 Hp
M
= 60 Hp
DIGIT 19 — Exhaust/Return RPM
Selection
0
= None
3
= 300
4
= 400
5
= 500
6
= 600
7
= 700
8
= 800
9
= 900
A
= 1000
B
= 1100
C
= 1200
D
= 1300
E
= 1400
DIGIT 20 — System Control Selection
1
= Constant Volume (CV) (Zone
Temperature Control)
2
= CV w/ Discharge Temp Control
4
= VAV w/ VFD Supply w/o Bypass
(Discharge Temp Control)
5
= VAV w/ VFD Supply w/ Bypass (Discharge
Temp Control)
6
= VAV – Single Zone VAV w/VFD w/o
Bypass (Zone Temperature Control)
7
= VAV – Single Zone VAV w/VFD w/ Bypass
(Zone Temperature Control)
DIGIT 21 — Outside Air and
Economizer Option/Controls
A
= 0-25% Motorized Damper
B
= Economizer w/Dry Bulb
C
= Economizer w/Reference Enthalpy
D
= Economizer w/Comparative Enthalpy
E
= Econ w/Outside Air Measure/Dry Bulb
F
= Econ w/Outside Air Measure/Ref Enthalpy
G
= Econ w/Outside Air Measure/Comp
Enthalpy
H
= Econ w/DCV/Dry Bulb
(a)
J
= Econ w/DCV/Ref Enthalpy
K
= Econ w/DCV/Comp Enthalpy
(a)
Requires CO
2
Zone Sensor(s)
DIGIT 22 — Damper Option
0
= Standard
1
= Low Leak
2
= Ultra Low Leak
U
= Ultra Low Leak, AMCA 1A, w/ FDD
(Design Special)
DIGIT 23— Pre-Evaporator Coil Filter
Selection
0
= Two Inch High Efficiency Throwaway
1
= Two Inch Throwaway Rack/Less Filters
2
= 90-95% Bag Filters w/ Prefilters
3
= Bag Filter Rack/Less Filters
4
= 90-95% Cartridge Filters w/ Prefilters
5
= Cartridge Rack/Less Filters
6
= 90-95% Low Pressure Drop Cartridge
Filters w/ Prefilters
7
= Low Pressure Drop Cartridge Rack/Less
Filters
DIGIT 24 — Blank Section Application
Options
0
= None
A
= 90-95% Bag w/ Prefilters
B
= 90-95% Low Pressure Drop Cartridge w/
Prefilters
C
= 90-95%, Cartridge Filters w/ Prefilters
D
= 90-95% High Temp Cartridge w/
Prefilters
E
= HEPA w/ Prefilters
F
= High Temp HEPA w/ Prefilters
DIGIT 25 — Energy Recovery Wheel
0
= None
1
= Low CFM ERW w/ Bypass Defrost
2
= Standard CFM ERW w/ Bypass Defrost
DIGIT 26 — Unit Mounted Power
Connection Selection
A
= Terminal Block
B
= Non-Fused Disconnect
C
= Non-Fused Disconnect w/ Powered
Convenience Outlet
D
= Unit Disconnect Switch w/ high fault
SCCR
E
= Unit Disconnect Switch w/ high fault
SCCR/ Powered Convenience Outlet
DIGIT 27 — Condenser Coil Selection
0
= Air-Cooled Aluminum
A
= Evap Condenser
B
= Evap Condenser w/ Sump Heater
E
= Evap Condenser w/ Conductivity
Controller
F
= Evap Condenser w/ Conductivity
Controller and Sump Heater
J
= Corrosion Protected Condenser Coil
DIGIT 28 — Capacity/Efficiency &
Drain Pan Option
0 = Standard Evap Coil w/ Galvanized Drain
Pan
A = Standard Evap Coil w/ Stainless Steel
Drain Pan
B = High Cap Evap Coil w/ Galvanized Drain
Pan
C = High Cap Evap Coil w/ Stainless Steel
Drain Pan
V = eFlex™ w/ Std evap coil w/ Galv drain pan
W = eFlex™ w/ Std evap coil w/ SS drain pan
Y = eFlex™ w/ Hi cap evap coil w/ Galv drain
pan
Z = eFlex™ w/ Hi cap evap coil w/ SS drain
pan
DIGIT 29 — Refrigeration System
Selection A
0
= Standard
A
= Suction Service Valves
B
= Replaceable Core Liquid Filter Driers
C
= Suction Service Valves & Replaceable
Core Liquid Filter Driers
DIGIT 30 — Refrigeration System
Selection B
0
= Standard
1
= Hot Gas Reheat
(a)
2
= Hot Gas By-Pass
3
= Hot Gas Reheat
/Hot Gas By-Pass
(a)
Humidity sensor required
DIGIT 31 — Ambient Control Option
0
= Standard Ambient
1
= Low Ambient
DIGIT 32 — High Duct Temp
Thermostat
0
= None
1
= High Duct Temp Thermostat
DIGIT 33 — Controls Option
0
= None
1
= Remote Human Interface (RHI) & Inter-
Processor Communication Bridge (IPCB)
2
= IPCB
3
= Rapid Restart
(a)
Requires CO
2
Zone Sensor(s)
(b)
Humidity sensor required