Performance Data
68
OAU-SVX004D-EN
Water Flow/Circuit, gpm (L/s)
18 (1.14)
21 (1.32)
24 (1.51)
27 (1.70)
Indoor Coil
Type
High Performance
High Performance
High Performance
High Performance
Tube Size—OD, in. (mm)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
Face Area, ft
2
(m
2
)
6.56 (0.61)
6.56 (0.61)
6.56 (0.61)
6.56 (0.61)
Rows
4
4
4
4
FPI
12
12
12
12
Refrigerant Control
TXV
TXV
TXV
TXV
Drain Connection Size, in. (mm)
3/4 (19.05)
3/4 (19.05)
3/4 (19.05)
3/4 (19.05)
Indoor Fan
Type
Backward Curved
Backward Curved
Backward Curved
Backward Curved
Number Used
1
1
1
1
Diameter
Varies
Varies
Varies
Varies
Drive Type
Direct Drive
Direct Drive
Direct Drive
Direct Drive
Number Motors
1
1
1
1
Motor HP (kW), Standard–Oversized
2.68-4.0 (2-3)
2.68-4.0 (2-3)
2.68-4.0 (2-3)
2.68-4.0 (2-3)
Motor RPM
Varies
Varies
Varies
Varies
Filters
Type Furnished
in
Refer to
Number/Size Recommended
Refrigerant Charge, lb of R-410A
See Nameplate
See Nameplate
See Nameplate
See Nameplate
Table 13. OABE general data—cooling 6–9 tons high efficiency (continued)
6 Tons
7 Tons
8 Tons
9 Tons
OABE072A
OABE084A
OABE096A
OABE108A
Table 14. OAGE general data—cooling 10–17 tons high efficiency
10 Tons Downflow
12 Tons Downflow
15 Tons Downflow
17 Tons Downflow
OAGE120
OAGE144
OAGE180
OAGE210
Performance
Gross Cooling Capacity, Btu (kW)
146,312 (42.88)
163,162 (47.82)
207,192 (60.72)
232,104 (68.02)
Gross Heating Capacity, Btu (kW)
132,672 (38.88)
150,140 (44.00)
193,968 (56.85)
219,778 (64.41)
Nominal cfm (m
3
/h)
1250–5000 (2124–8495) 1500–5000 (2549–8495) 1875–5000 (3186–8495) 2188–5000 (3717–8495)
Compressor
Number
2
2
2
2
Type
Scroll
Scroll
Scroll
Scroll
Fluid/Refrigerant Water Coil
Type
Coaxial
Coaxial
Coaxial
Coaxial
Connection Size/Circuit, in. (mm)
1 (25.4)
1.5 (38.1)
1.5 (38.1)
2 (50.8)
Pressure Drop/Circuit, ft wc (kPa)
3.5/3.5 (10.46/10.46)
4.7/4.7 (14.05/14.05)
3.2/3.2 (9.56/9.56)
3.3/3.3 (9.86/9.86)
Water Flow/Circuit, gpm (L/s)
15/15 (0.95/0.95)
18/18 (1.14/1.14)
21/21 (1.32/1.32)
26/26 (1.64/1.64)
Indoor Coil
Type
High Performance
High Performance
High Performance
High Performance
Tube Size—OD, in. (mm)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
Face Area, ft
2
(m
2
)
10 (0.93)
10 (0.93)
10 (0.93)
10 (0.93)
Rows
4
4
4
4
FPI
12
12
12
12
Refrigerant Control
TXV
TXV
TXV
TXV
Drain Connection Size, in. (mm)
1 (25.4)
1 (25.4)
1 (25.4)
1 (25.4)
Indoor Fan
Type
Backward Inclined
Backward Inclined
Backward Inclined
Backward Inclined
Number Used
1–2
1–2
1–2
1–2
Diameter
Varies
Varies
Varies
Varies
Drive Type
Direct Type
Direct Type
Direct Type
Direct Type
Содержание Horizon OABE/F
Страница 32: ...Unit Clearances Curb Dimensions and Dimensional Data 32 OAU SVX004D EN ...
Страница 37: ...Unit Weight and Rigging OAU SVX004D EN 37 ...
Страница 55: ...Installation OAU SVX004D EN 55 ...
Страница 78: ...Performance Data 78 OAU SVX004D EN ...
Страница 84: ...Appendix 84 OAU SVX004D EN Figure 79 BAYSENS036A installation instructions ...
Страница 85: ...Appendix OAU SVX004D EN 85 Figure 80 VELCON 0351 installation instructions ...
Страница 89: ...Appendix OAU SVX004D EN 89 ...
Страница 90: ......
Страница 91: ......