To check the humidifier’s operation, note the Control setting and set the 
Automatic Humidifier Control to the test mode when the furnace blower 
motor is operating. Water will flow into the humidifier for 1 minute and 
then it will turn off. This insures the humidifier is operating properly. Do 
not leave the Control in the test mode as it will not operate. Reset the 
Control to it’s original setting.

TABLE 3 – Outdoor-Indoor Relative Humidity

Model EHUMD200ABM00B with Manual Humidifier Control  
or Model EHUMD300ABA00B and EHUMD500APA00C with 
Automatic Humidifier Control in Manual Mode:  

(for Automatic Humidifier Control – see page 3)
The Manual Humidifier Control is installed either in the living area (typically 
near the thermostat) or in the cold air return. The Automatic Humidifier 
Control (in the Manual Mode) is installed in the cold air return. It is 
important to anticipate a drop in outdoor temperature and reduce the setting 
accordingly to avoid excessive condensation. For example, with an outdoor 
temperature of 20°F the recommended setting will be 35% relative humidity. 
If the temperature is expected to fall to 0°F that evening, then merely reduce 
the setting to 25% several hours prior to the temperature change.
The recommended settings on the Humidifier Control are based on years 
of research (see Table 3) and experience as to what is best for the average 
home. These settings represent a compromise between RH levels that would 
be most desirable for comfort reasons and humidity levels that are suitable 
for protection of your home. For example, a wintertime indoor RH of 50% 
may be considered ideal by some, but unfortunately, it probably would result 
in damage to your home. Observance of the recommended RH levels on 
your Humidifier Control, therefore, is an important safeguard. Condensation 
of water on inside windows in the form of fogging or frost is usually an 
indication of too high relative humidities. This same condensation can take 
place in other areas in your home with the possibility of damage resulting.

 

Outside Temperature  

Recommended RH

 +40°F 

45%

 +30°F 

40%

 +20°F 

35%

 +10°F 

30%

 0°F 

25%

 –10°F 

20%

 –20°F 

15%

The Humidifier Control is a precision instrument that can be used to 
determine the RH accurately in your home during the winter. Turn the dial 
to the lower setting, then reverse the dial direction slowly until a “click” is 
heard. At this point, read the RH on the dial. This will be very close to the 
actual RH in your home.

EFFECT OF WATER CHARACTERISTICS

To check the humidifier operation, set the Humidifier Control above the 
click point, make sure that the water saddle valve is open and that there is 
electricity to the humidifier. Generally, the furnace and blower motor must 
be operating for the Humidifier Control to function. After the humidifier has 
operated for several minutes and water is entering the humidifier and coming 
out at the drain, reduce the Humidifier Control setting below the click point 
and the humidifier should automatically shut off. Now set the Humidifier 
Control dial at the recommended inside relative humidity, depending on the 
outside temperature. Follow the suggested settings prior to a drop in the 
outside temperature.

Additional Information

Be sure to keep fireplace dampers closed when not in use. They provide 
an excellent escape route for heat, as well as humidity. Humidity is lost 
at an even faster rate than heat because water vapor tends to seek its 
own level and your humidifier would not be able to replace it even when 
running at full capacity. 
On occasion, indoor moisture producing activities such as clothes drying, 
cooking, showers, etc., may raise the relative humidity level higher 
than it should be, even though the Humidifier is not operating. Telltale 
indications, again, are condensation or frost on cold surfaces such as 
windows, doors, walls, etc. If such condensation persists for several hours, 
your home should be ventilated to dissipate the potentially damaging 
excess moisture.

Your humidifier will operate effectively using either hot, cold, hard or 
mechanically softened water. Whether to use available tap water, even 
though it may be quite hard, or chemically softened water, is a common 
concern to homeowners when installing a humidifier. Because of the 
humidifier’s design, most of these solids are effectively controlled by 
flushing them down the drain.
Water used in homes contains varying amounts of minerals. The residue 
remaining as a result of hard water evaporation is primarily calcium and 
magnesium components and is usually quite hard, scaly, and dense.
Residue from softened water tends to be soft and fluffy and has a greater 
volume than hard water residue. The service life of a Humidifier Pad 
may be extended by using hard water, but in either case, the Humidifier 
Pad should be changed once a year. This is why proper maintenance 
is important and necessary. Service hot water 140°F maximum, is 
recommended with flow through, drain type units for increasing capacity.

Содержание EHUMD200ABM00B

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USE AND CARE MANUAL Includes Safety Operating Instructions For Models EHUMD200ABM00B EHUMD300ABA00B EHUMD500APA00C ...

Страница 2: ...r new humidifier has been installed to operate in conjunction with your furnace When the Humidifier Control calls for humidity and the furnace blower is operating water flows to the distribution tray located at the top of the humidifier The water is evenly distributed across the width of the tray and over the Humidifier Pad Dry hot air is moved through this moisture laden Humidifier Pad where it i...

Страница 3: ... setting in the event you temporarily move the knob when performing annual maintenance of the Humidifier OPERATING INSTRUCTIONS FIGURE A 90 1054 Your Automatic Humidifier is a high precision system that will accurately maintain the relative humidity in your home For every 1 F change in outdoor temperature the Control will automatically adjust the indoor relative humidity RH by 1 2 If you would lik...

Страница 4: ... RH on the dial This will be very close to the actual RH in your home EFFECT OF WATER CHARACTERISTICS To check the humidifier operation set the Humidifier Control above the click point make sure that the water saddle valve is open and that there is electricity to the humidifier Generally the furnace and blower motor must be operating for the Humidifier Control to function After the humidifier has ...

Страница 5: ...e property damage personal injury or death CAUTION Turn Humidifier Control to OFF or lowest setting before servicing Sudden operation may cause personal injury or property damage 1 Disconnect electrical power to the furnace and shut off water supply 2 Disconnect the water line at the inlet compression nut 3 Remove the in line strainer from inside the inlet side of the valve by using a small nail o...

Страница 6: ...UMIDIFIER MODEL EHUMD500APA00C MODEL EHUMD500APA00C 1 Humidifier Cover Assembly 2 Base Assembly 3 Evaporative Assembly 4 Distribution Tray 5 V Notches 6 Humidifier Pad 7 Scale Control Insert 8 Drain Line 9 Power Cord WARNING Disconnect Electrical Power and Shut Off Water Supply Before Servicing Failure to follow this warning may cause property damage personal injury or death CAUTION Turn Humidifie...

Страница 7: ...10012947 9 21 Pub No 32 5036 7A B2207981B Printed in U S A Trane 6200 Troup Highway Tyler TX 75711 9010 ...

Страница 8: ...E ET CONSERVER CES DIRECTIVES HUMIDIFICATEURS MANUEL D UTILISATION ET D ENTRETIEN Comprend les directives sur la sécurité et le fonctionnement Pour les modèles EHUMD200ABM00B EHUMD300ABA00B EHUMD500APA00C ...

Страница 9: ...e de l humidificateur réclame de l humidité et que le ventilateur de la fournaise fonctionne de l eau s écoule jusqu au plateau de distribution situé dans le haut de l humidificateur L eau est distribuée uniformément sur la largeur du plateau et sur le tampon humidificateur De l air sec et chaud est déplacé à travers le tampon humidificateur chargé d humidité où il est transformé en vapeur Cet air...

Страница 10: ...e subséquentes Notez le réglage du cadran au cas où vous déplaceriez temporairement le bouton pour effectuer l entretien annuel de l humidificateur DIRECTIVES D UTILISATION FIGURE A 90 1054 Votre humidificateur automatique est un système à haute précision qui gardera avec exactitude l humidité relative dans votre maison Pour chaque 1 F 0 5 C de variation de température intérieure la commande règle...

Страница 11: ... Cela sera très près de l HR actuelle dans votre maison EFFET DES CARACTÉRISTIQUES DE L EAU Pour vérifier le fonctionnement de l humidificateur réglez la commande de l humidificateur au dessus du point du clic en vous assurant que le robinet valve d eau est ouvert et que l humidificateur est alimenté en électricité Généralement la fournaise et le moteur du ventilateur doivent fonctionner pour que ...

Страница 12: ...E EN GARDE Mettez la commande de l humidificateur à OFF arrêt ou au réglage le plus bas avant d effectuer tout service Un fonctionnement soudain peut causer des blessures ou des dommages matériels 1 Débranchez l alimentation électrique jusqu à la fournaise et coupez l alimentation en eau 2 Débranchez la conduite d eau au niveau de l écrou de compression d admission 3 Retirez la crépine en ligne de...

Страница 13: ...L HUMIDIFICATEUR MODÈLE EHUMD500APA00C MODÈLE EHUMD500APA00C 1 Assemblage du couvercle de l humidificateur 2 Assemblage de la base 3 Ensemble d évaporation 4 Plateau de distribution 5 Encoches en V 6 Tampon humidificateur 7 Élément d élimination des dépôts 8 Conduite d évacuation 9 Cordon d alimentation a AVERTISSEMENT Débranchez le courant et coupez l alimentation en eau avant d effectuer tout se...

Страница 14: ...10012947 9 21 Pub Nº 32 5036 7A B2207981B Imprimé aux É U Trane 6200 Troup Highway Tyler TX 75711 9010 ...

Отзывы: