background image

SUPPLY AIR

RETURN AIR

OPTIONAL FLUE

NOT ALL MODELS

HUMIDIFIER

SUPPLY

AIR 

RETURN

AIR

RETURN

AIR

SUPPLY

AIR 

RETURN

AIR

SUPPLY

AIR 

COOLING

COIL

COOLING

COIL

HUMIDIFIER

HUMIDIFIER

FLUE

FLUE

COOLING COIL

HUMIDIFIER

COOLING COIL

SUPPLY AIR

RETURN AIR

OPTIONAL FLUE

NOT ALL MODELS

HUMIDIFIER

SUPPLY

AIR 

RETURN

AIR

RETURN

AIR

SUPPLY

AIR 

RETURN

AIR

SUPPLY

AIR 

COOLING

COIL

COOLING

COIL

HUMIDIFIER

HUMIDIFIER

FLUE

FLUE

COOLING COIL

HUMIDIFIER

COOLING COIL

SUPPLY AIR

RETURN AIR

OPTIONAL FLUE

NOT ALL MODELS

HUMIDIFIER

SUPPLY

AIR 

RETURN

AIR

RETURN

AIR

SUPPLY

AIR 

RETURN

AIR

SUPPLY

AIR 

COOLING

COIL

COOLING

COIL

HUMIDIFIER

HUMIDIFIER

FLUE

FLUE

COOLING COIL

HUMIDIFIER

COOLING COIL

SUPPLY AIR

RETURN AIR

OPTIONAL FLUE

NOT ALL MODELS

HUMIDIFIER

SUPPLY

AIR 

RETURN

AIR

RETURN

AIR

SUPPLY

AIR 

RETURN

AIR

SUPPLY

AIR 

COOLING

COIL

COOLING

COIL

HUMIDIFIER

HUMIDIFIER

FLUE

FLUE

COOLING COIL

HUMIDIFIER

COOLING COIL

120 VAC

TRANSFORMER

(FURNISHED)

24

VAC

WATER SUPPLY

CONNECT DRAIN LINE HERE  

SHUT-OFF

(SADDLE VALVE)

YELLOW 24 V

SOLENOID

VALVE WIRES

MANUAL

HUMIDIFIER CONTROL

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock. 

This product must be installed in compliance with all local, state and federal codes. 

If the furnace has central cooling, the humidifier bypass damper must be closed during the cooling season.

ATTENTION INSTALLER:

BYPASS HUMIDIFIER MODEL EHUMD200A

The humidifier can be installed on either the supply or return plenum of a forced 

air handling system and is easily reversible for installation with right hand or  

left hand bypass duct connections. The humidifier dimensions and serviceability 

must be considered when selecting the best location for the humidifier.

Downflow Furnace

Horizontal Furnace

Upflow Furnace

OPTION “A” REAR OF FURNACE  

OR REAR MOUNT

Upflow Furnace

OPTION “B” FRONT OF FURNACE  

OR FRONT MOUNT

IMPORTANT

USE THE 120 VAC 
POWER SOURCE ON THE 
INTEGRATED FURNACE 
CONTROL HUMIDIFIER 
ACCESSORY TERMINALS 
MARKED HUM‑H, HUM‑N  
TO POWER THE HUMIDIFIER 
CONTROL TRANSFORMER.

90‑1104

90‑1105

WARNING

1. 

 ELECTRICAL SHOCK HAZARD.

 

Disconnect electrical power to the 

furnace before starting installation. 

Failure to do so could result in 

serious injury from electrical shock.

2. 

 SHARP EDGES HAZARD.

 Sharp 

edges may cause serious injury from 

cuts. Use care when making plenum 

openings and handling ductwork. Use 

personal protective equipment when 

installing HVAC equipment.

3. 

 RISK OF SCALDING.

 Water 

temperature over 125°F can cause 

severe burns and scald instantly. 

Shut off the hot water supply before 

disconnecting or tapping into any hot 

water supply line.

SPECIFICATIONS

HUMIDIFIER DIMENSIONS

Width 

(including solenoid valve):

 15

5

8

” 

Height 

(including drain spud):

 13” 

Depth

:

 10

1

4

BYPASS DUCT OPENING

6” diameter

PLENUM OPENING

9

1

2

”W x 9

1

2

”H

WATER FEED RATE

3 gph

ELECTRICAL DATA

24 VAC‑60 Hz, 0.5 AMP 

CAUTION

1.  Do not install humidifier in attic or crawl areas.
2.  Do not install humidifier where freezing temperatures 

could occur. The water line could freeze and crack 

causing water damage to the home.

3.  Do not install humidifier or bypass connection on the 

furnace cabinet.

4.  Do not install humidifier or bypass connection on a 

plenum face where the blanked off ends of the cooling 

coil will restrict air movement through the humidifier.

5.  Do not set humidity level above recommended or to 

recommended level if condensation exists on inside 

windows of any unheated space, as condensation 

damage may result. Excess humidity can cause 

moisture accumulation which can allow the possibility 

for mold growth in your home.

6.  Do not connect humidifier transformer to 

blower motor wiring. Premature component 

failure may result.

7.  When installing Manual Humidifier Control on 

downflow furnace, ensure blower continues 

to run after a heat call is satisfied to eliminate 

high temperatures from damaging the Control.

8.  Do not install humidifier where water pressure 

exceeds 125 psi, since damage to the 

humidifier may result. Follow codes in effect 

concerning pressure reduction.

9.  Do not install humidifier on the supply plenum 

where static pressure exceeds 0.2” W.C.

RISK OF PROPERTY AND EQUIPMENT DAMAGE.

INSTALLATION OPTIONS

WIRING DIAGRAM

IMPORTANT

NOTE:

 THE INTEGRATED FURNACE CONTROL HAS OPTIONAL 

ACCESSORY CONNECTIONS FOR THE HUMIDIFIER. SEE THE 
FURNACE INSTALLER’S GUIDE FOR THE SCHEMATIC DIAGRAM 
OF THE FURNACE AND THE FIELD WIRING DIAGRAM FOR THE 
OPTIONAL ACCESSORIES.

NOTE:

 FOR COMMUNICATING SYSTEM 

WIRING DIAGRAMS, SEE ENCLOSED 
INSTALLER’S GUIDE, FORM 18‑HE87D1‑3.

TEMPLATE MUST BE LEVEL

Trane  
Ingersoll Rand
6200 Troup Highway
Tyler, TX 75711-9010

READ COMPLETE SAFETY INSTRUCTIONS, PRE-INSTALLATION SETUP AND CHECKOUT PROCEDURE 

FOR BYPASS HUMIDIFIER AND INSTALLATION / TEMPLATE INSTRUCTIONS BEFORE STARTING