background image

ComfortLink

™ 

II XL 1040

TZON1040 Zone Sensor  

Installation & User Guide

The 1040 is an easy to use communicating zone sensor with a color touch screen.

This guide will help you install and configure your TZON1040 zone sensor quickly and easily.

18-HD88D1-1D-EN

Содержание ComfortLink II XL 1040

Страница 1: ...1040 Zone Sensor Installation User Guide The 1040 is an easy to use communicating zone sensor with a color touch screen This guide will help you install and configure your TZON1040 zone sensor quickly...

Страница 2: ...color touch screen zone sensor represent the ultimate in climate control and comfort technology from the industry s leader in residential HVAC systems CONTENTS Welcome 1 User Guide 2 Touch Screen 2 H...

Страница 3: ...AUTION Do not use hard or sharp objects to touch the screen The 1040 utilizes a resistive touch screen which allows you to apply light pressure with your finger or any non sharp object in order to int...

Страница 4: ...ing temperature adjustment Current temperature and status Current Outdoor Temperature Menu Screen Day Date Day Date Time set on 1050 control Time Fan Mode Auto On View and adjust other zone settings P...

Страница 5: ...1040 System Mode is bound to the 1050 System Mode and cannot be modified from the 1040 zone sensor The Fan Mode button allows you to choose between Auto or On fan modes Auto Fan Mode turns the fan off...

Страница 6: ...oot Clean Screen About Rename sensor Reboot the zone sensor Model and serial number software version other zone sensor information Clean screen function Return to the Home Screen Menu Screen Display f...

Страница 7: ...gn a unique name to the 1040 zone sensor On first boot up this screen will appear to allow you to set a name for the 1040 zone sensor The sensor name may include up to 20 characters Select Done to app...

Страница 8: ...ncel Apply Screen Settings Select a tab to view different screen setting options Adjust the screen active and standby brightness Navigate to Screen Settings by selecting Home Screen Menu Screen Settin...

Страница 9: ...n to the Menu without saving Screen Settings Cancel Apply Adjust how long the screen will remain active after the last screen touch Backlight Apply changes Navigate to Screen Settings by selecting Hom...

Страница 10: ...Select the screen saver you would like displayed during standby mode Adjust how long the zone sensor will wait to display screen saver Screen Saver Return to the Menu without saving Apply changes Nav...

Страница 11: ...uide Cancel Apply Screen Settings Select a custom color theme for the zone sensor Color Themes Return to the Menu without saving Apply changes Navigate to Screen Settings by selecting Home Screen Menu...

Страница 12: ...e 11 TZON1040 Installation and User Guide User Guide Calibration Adjust the Indoor Temp and Humidity values Return to the Menu Navigate to the Calibration screen by selecting Home Screen Menu Calibrat...

Страница 13: ...t the zone sensor with the push of a button When you select this option you will be prompted to ensure you would like to reboot your zone sensor NOTE The HVAC system will not stop operation while the...

Страница 14: ...ring guidelines cannot be met Ground only one end of the shield to the system chassis This information is intended for use by individuals possessing adequate backgrounds of electrical and mechanical e...

Страница 15: ...ps slotted head mounting screws 2 6x1 Nylon Drywall Anchors 1 Installation and User Guide 1 USB On the Go Adapter Cable Micro USB plug to Standard USB receptacle The 1040 Connected Zone Sensor has a 4...

Страница 16: ...040 to heat radiated from lamps sun light fireplaces or any other radiant heat source Avoid locations close to windows behind doors or alcoves with poor air circulation adjoining outside walls or door...

Страница 17: ...s heat which is vented out the top of the zone sensor utilizing natural convection If an air source is directed at or from above heat from the screen can be trapped within the zone sensor and may caus...

Страница 18: ...all 3 Carefully pry the sub base away from the 1040 using a small flat blade screwdriver Note that the tight fit is normal and ensures that the sensor is held securely to the sub base when mounted on...

Страница 19: ...the proper terminal on the connector block of the sub base Strip 1 4 of insulation from each wire Do not allow adjacent wires to short together when connected 2 Match and connect zone sensor wires to...

Страница 20: ...hen select the 1040 on the right column and select Assign Once assigned the sensor will move over to the left column and average with the other sensors assigned in that zone You can assign up to 4 sen...

Страница 21: ...page 20 18 HD88D1 1D EN page 20 Installation To unassign the 1040 select the desired sensor and then select Unassign The sensor will move back to the list of Available Sensors Zone Assignment...

Страница 22: ...for five seconds NOTE Screen Calibration is available for five minutes if the screen has never been calibrated If the screen is not pressed within five seconds the zone sensor will default to previous...

Страница 23: ...page 22 18 HD88D1 1D EN This page left intentionally blank...

Страница 24: ...s a policy of continuous data improvement and it reserves the right to change design and specifications without notice We are committed to using environmentally conscious print practices Representativ...