Trane CleanEffects Air Filtration System Скачать руководство пользователя страница 3

32-5038-06

Numbers in [brackets] are for 50 Hz international systems.

3

User’s Information

SEQUENCE OF OPERATION

Turn on the unit by pressing and releasing the POWER
button.  The backlit POWER and RESET button will
illuminate along with the first green LED indicating power
is present.  When the indoor fan is operating the first
green LED will slowly flash. This indicates the FIELD
CHARGER and COLLECTION CELLS have power and
the unit is operating normally. There is a slight time
delay between the indoor fan starting and LED flashing.

NOTE: There is a 10 [12] minute delay after the indoor
fan operates, before the air cleaner starts to operate,
each time the power to the air cleaner is turned off/on.

Your air filtration system only operates when the air is
circulating through the indoor unit.  The air filtration
system is most effective at cleaning the air if the fan
operates continuously. Most thermostats have a
setting that will permit continuous fan operation.

Continuous fan mode during Cooling operation
may not be appropriate in humid climates.  If the
indoor air exceeds 60% relative humidity or simply
feels uncomfortably humid, it is recommended that
the fan only be used in the AUTO mode.

In normal operation, the air cleaner may make a slight
sound as the air passes through it and is cleaned.  In
some applications, you may notice this sound coming
from the return air vent(s).  If desired, this sound level
can be  reduced with minimal impact on air cleaning
efficiency by reducing the power setting of the FIELD
CHARGER in the SET-UP mode (see  pages 7-8).

MAINTENANCE

WARNING

!

RISK OF ELECTRIC SHOCK: These servicing
instructions are for use by qualified personnel
only. To reduce the risk of electric shock, do not
perform any servicing other than that contained in
this User's Information Guide unless you are
qualified to do so.

CAUTION

!

Before cleaning the coil or ducts in the air handler or
furnace, remove the COLLECTION CELLS, FIELD
CHARGER, and PRE-FILTER from the air cleaner.
Chemicals used during the cleaning of the air
handler, furnace, or ductwork can damage the air
cleaner components and degrade the performance of
the air cleaner.

For maximum efficiency, the COLLECTION CELLS and
PRE-FILTER should be inspected and cleaned as
prescribed in this User's Information Guide.

The FIELD CHARGER should only be removed and
cleaned annually by a qualified service professional.

CLEANING

Cleaning Instructions:
The air cleaner utilizes a PRE-FILTER and
COLLECTION CELLS. The purpose of the PRE-FILTER
is to capture large particles before they enter the
COLLECTION CELLS which allows the COLLECTION
CELLS to work more efficiently.

1.    Turn the air conditioning system off at the Comfort

Control (thermostat).

WARNING

!

High Voltage is present within the air cleaner for
operation.  Before removing the Power Door, turn the
power off and wait at least 15 seconds to allow
voltage to discharge.  Failure to follow instructions
could result in death or serious personal injury.

2.   Turn off power to the air cleaner by pushing and

holding the POWER button for three seconds.  The
LED’s will remain on until the voltage has discharged
and it is safe to remove the door. This requires
approximately 15 seconds.  

Do not remove the

door until all the lights are off.

3.   Disconnect the power/control cable.

4.   Rotate the two latches and remove the door as

shown in Figure 3.  Place the door in a secure
location.

Fig. 3

Rotate Latches

CAUTION

!

Handle the door only by using the handles on the
front of the door.  Grasp the door by the handles as
depicted in Figure 3 to remove and replace the door.
Do not handle the door on the edges.  Metal edges
may be sharp and could result in injury if the door is
not handled properly.

Содержание CleanEffects Air Filtration System

Страница 1: ...ost advanced innovative and effective whole house air filtration system on the market today It is designed to deliver what we call TRANE AirTM throughout your home It delivers air that is meticulously filtered and cleaned of up to 99 98 of allergens to provide maximum comfort You and your family can breathe easier than ever before Trane 2008 32 5038 06 ...

Страница 2: ...nvert the 24 Volt AC to the high voltage direct current required to power the FIELD CHARGER and COLLECTION CELLS Allows access to the COL LECTION CELLS FIELD CHARGER and PRE FILTER 6 24 VOLT POWER CABLE DISPLAY FEATURES The air cleaner display Fig 2 has the following functions LED and PRE FILTER lights display the operating status of the air cleaner indicating when to clean the PRE FILTER or COLLE...

Страница 3: ...han that contained in this User s Information Guide unless you are qualified to do so CAUTION Before cleaning the coil or ducts in the air handler or furnace remove the COLLECTION CELLS FIELD CHARGER and PRE FILTER from the air cleaner Chemicals used during the cleaning of the air handler furnace or ductwork can damage the air cleaner components and degrade the performance of the air cleaner For m...

Страница 4: ...n to red When the last red indicator is flashing it is time to clean the COLLECTION CELLS see Figure 6 The air cleaner is factory set to notify the home owner to clean the COLLECTION CELLS every six months 31 weeks of actual run time of the air cleaner This notification can be changed by the installer home owner to 2 months 4 months 6 months or 9 months 10 20 31 or 46 weeks depending on the condit...

Страница 5: ...or arrow on the PREFILTER is pointing in the same direction as the AIRFLOW indicator arrow on the air cleaner cabinet 2 Reinstall the COLLECTION CELLS into the air cleaner Ensure the handles on both of the COL LECTION CELLS are folded flat Handles Fold Flat 3 Replace the power door onto the air cleaner To install the door follow the instructions in Figures 11 14 below 1 Using a vacuum hose vacuum ...

Страница 6: ... soap or detergent in cleaning the COL LECTION CELLS Do NOT immerse the COLLECTION CELLS com pletely in water Do NOT place the COLLECTION CELLS into a dish washer to clean ALLOW THE COLLECTION CELLS TO DRY THOR OUGHLY BEFORE INSTALLING Fig 16 Rotate latches to secure door Fig 15 Fig 13 Rotate door to closed position Ensure ends of door overlap cabinet See detail Cabinet Edge Plug Power Cord in her...

Страница 7: ...rval for one two or three months 5 10 or 15 weeks The number of illuminated GREEN LED lights indicates the current setting The factory setting is 2 months 10 weeks of run time see Figure 19 COLLECTION CELL Timer Setting The YELLOW LED lights are used to set the COLLEC TION CELLS cleaning interval for two four six or nine months 10 20 31 or 46 weeks The number of illuminated YELLOW LED lights indic...

Страница 8: ... button again FIELD CHARGER Power Level Setting Figure 22 One or more of the RED LED lights will illuminate To change the power level setting press the RESET button until the desired setting is indicated To save your new settings and exit the SET UP mode press and hold BOTH the Power and filter RESET buttons for a minimum of 5 6 seconds G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y1 Y3 Y4 R...

Страница 9: ... COLLECTION CELLS to insure no large material is trapped in the filters and causing the fault See pages 3 7 for cleaning information NOTE If collection cells are wet you may see this fault indication Turn air cleaner off until collection cells are completely dry If the unit detects any other type of fault all three RED LED lights will flash continuously as shown in Figure 24 The filter will shut d...

Страница 10: ...anEffects Air Cleaner is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations in its Installer s Guide and 3 in compliance with all industry standards national state and local codes This limited warranty does not cover your CleanEffects Air Cleaner if it is damaged while in your possession including but not limited to ...