32-5038-10 

Numbers in [brackets] are for 50 Hz international systems. 

9

User’s Information

SET-UP MODE

You can customize the operation of the CleanEffects

TM 

air cleaner to meet the needs of your home and family 
using the SET-UP mode.  The Comfort Control should 
be in "Auto Detect" mode.
To enter the SET-UP mode, press and hold BOTH the 
POWER and the RESET buttons for a minimum of 5 [6] 
seconds.   The LED display will light up indicating the 
current settings.  If the settings were not changed during 
installation into your home, the LED's will light up with 
the factory settings as shown in Figure 19.

2.   After washing, drain as much water as possible from 

the COLLECTION CELLS.

3.    Holding the sides of the COLLECTION CELLS, 

gently tap the cells on a flat surface to dislodge any 

water droplets inside the COLLECTION CELLS. Af-

ter tapping, wipe down the surfaces of the COLLEC-

TION CELLS to remove any visible droplets of water. 

Fig. 17

4.    When there are no visible water droplets left in the 

COLLECTION CELLS, reinstall them into the air 

cleaner cabinet. Be sure to fold the COLLECTION 

CELL handles flat.

Tap 
Gently

Handles Fold

Flat

Fig. 18

Fig. 19

You may select the cleaning intervals of the PRE-
FILTER and the COLLECTION CELLS as well as the 
power setting of the FIELD CHARGER by cycling 
through the various settings.  Once you have made the 
desired changes, press and hold BOTH the POWER 
and the filter RESET buttons for a minimum of 5 [6] 
seconds to exit the SET-UP mode.

PRE-FILTER Timer Setting

The GREEN LED lights are used to set the PRE-FILTER 
cleaning interval for one, two, or three months [5, 10, 
or 15 weeks].  The number of illuminated GREEN LED 
lights indicates the current setting.  The factory setting is 
2 months [10 weeks] of run time (see Figure 19).

COLLECTION CELL Timer Setting

The YELLOW LED lights are used to set the COLLEC-
TION CELLS cleaning interval for two, four, six, or nine 
months  [10, 20, 31, or 46 weeks].  The number of illumi-
nated YELLOW LED lights indicates the current setting 
as shown in Figure 19.  The factory setting is 6 months 
[31 weeks] of run time.

G1

G2

G3

Y1

Y3

Y4

R1

R2

R3

Y2

CLEAN

DIRTY

Power Level

Collection Cell

Pre-Filter

Factory settings

FIELD CHARGER Power

Maximum

COLLECTION CELL

6 Months [31 weeks]

PRE-FILTER

2 Months [10 weeks]

NOTE: If collection cells are wet, you may see a fault 
indication.  Turn air cleaner off until collection cells are 
completely dry.

RESET TIMERS

When installed as part of a Communicating System with 
a 900 series comfort control, the filter timers can be 
reset at either the Comfort Control or the air cleaner.  
To reset the Pre Filter timer at the comfort control Select 
Filter 1 Change Reminder, then press the MORE key to 
access the filter timer value and then press the RESET 
key. 
To reset at the air cleaner press and hold the RESET 
key until the PREFILTER LED turns off (1 to 2 seconds).

To reset the Collection Cell timer at the Comfort Control 
select Filter 2 Change Reminder, then press the More 
key to access the filter timer value and then press the 
Reset key.  
To reset the Collection Cell timer at the air cleaner press 
and hold the RESET key until the COLLECTION CELL 
LED turns off (1 to 2 seconds).  
If two air cleaners are connected on the same system, 
reset all timers on both air cleaners at the same time to 
the same settings. The comfort control will only report 
one air cleaner timer and this methodology will allow the 
air cleaners to remain on the same cleaning schedule.
For additional information please refer to the Installers 
Guide and/or Service Facts for the 900 Series control.  
However, in a system with dual air cleaners,the 900 
series comfort control will only recognize the timer for 
one air cleaner.   Reset the filter timer at the comfort 
control using the instructions given above.

Содержание CleanEffects 32-5038-10

Страница 1: ...ost advanced innovative and effective whole house air filtration system on the market today It is designed to deliver what we call TRANE AirTM throughout your home It delivers air that is meticulously filtered and cleaned of up to 99 98 of allergens to provide maximum comfort You and your family can breathe easier than ever before Trane 2013 32 5038 10 ...

Страница 2: ...24 volt system When installed as part of a Communicating System in which the indoor unit furnace or air handler outdoor unit air conditioner or heat pump and comfort control are equipped with our exclusive Communicating technology your system performs a continuous loop of system diagnostics and data output The Communicating System monitors itself and quickly identifies any operational faults autom...

Страница 3: ...nvert the 24 Volt AC to the high voltage direct cur rent required to power the FIELD CHARGER and COLLEC TION CELLS Allows access to the COLLECTION CELLS FIELD CHARGER and PRE FILTER 6 24 VOLT POWER CABLE DISPLAY FEATURES The air cleaner display Fig 2 has the following functions LED and PRE FILTER lights display the operating status of the air cleaner indicating when to clean the PRE FILTER or COLL...

Страница 4: ... air cleaner may make a slight sound as the air passes through it and is cleaned In some applications you may notice this sound coming from the return air vent s If desired this sound level can be reduced with minimal impact on air cleaning efficiency by reducing the power setting of the FIELD CHARGER in the SET UP mode see pages 9 10 CAUTION Before cleaning the coil or ducts in the air handler or...

Страница 5: ...CELLS which allows the COLLECTION CELLS to work more efficiently 1 Turn the air conditioning system off at the Comfort Control thermostat WARNING High Voltage is present within the air cleaner for operation Before removing the Power Door turn the power off and wait at least 15 seconds to allow voltage to discharge Failure to follow instructions could result in death or serious personal injury 2 Tu...

Страница 6: ...hts will progress from green to yellow and then to red When the last red indicator is flashing it is time to clean the COLLECTION CELLS see Figure 6 The air cleaner is factory set to notify the home owner to clean the COLLECTION CELLS every six months 31 weeks of actual run time of the air cleaner This notification can be changed by the installer home owner to 2 months 4 months 6 months or 9 month...

Страница 7: ...r arrow on the PREFILTER is pointing in the same direction as the AIRFLOW indicator arrow on the air cleaner cabi net 2 Reinstall the COLLECTION CELLS into the air cleaner Ensure the handles on both of the COL LECTION CELLS are folded flat Handles Fold Flat 3 Replace the power door onto the air cleaner To install the door follow the instructions in Figures 11 14 below 1 Using a vacuum hose vacuum ...

Страница 8: ...BEFORE INSTALLING Fig 16 Rotate latches to secure door Fig 15 Fig 13 Rotate door to closed position Ensure ends of door overlap cabinet See detail Cabinet Edge Plug Power Cord in here Power Button Amber Light Fig 14 The whole house air cleaner can be connected in one of two modes of operation either a 24 V mode or a communicating mode To know how the whole house air cleaner is set up reference Fig...

Страница 9: ...he YELLOW LED lights are used to set the COLLEC TION CELLS cleaning interval for two four six or nine months 10 20 31 or 46 weeks The number of illumi nated YELLOW LED lights indicates the current setting as shown in Figure 19 The factory setting is 6 months 31 weeks of run time G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Power Level Collection Cell Pre Filter Factory settings FIELD CHARGER Power Ma...

Страница 10: ... R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Y1 G1 G2 G3 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Y1 Y1 G1 G2 G3 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Y1 Two Months 10 Weeks Four Months 20 Weeks Six Months 31 Weeks Nine Months 46 Weeks Fig 21 G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Minimum Medium Maximum Fig 22 Fact...

Страница 11: ...e POWER button for three seconds The LED s will remain on until the voltage has discharged and it is safe to remove the door This requires approximately 15 seconds Do not remove the door until all the lights are off 2 Clean both the PREFILTER and the COLLECTION CELLS to insure no large material is trapped in the filters and causing the fault See pages 4 9 for cleaning information NOTE If collectio...

Страница 12: ...s a policy of continuous product and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor ...

Отзывы: