9

UNT-SVU001-EN

1. Fan

Three fan speed (high, medium,
low) can be selected. The fan
speed can also be put in AUTO
fan mode. It will be changed
automatically from high to medium
and low according to the difference
between room and setting
temperature.

2. Power On/Off

Press POWER button will turn on/
off the air conditioner. When turned
on, it will operate according to the
last program setting.

3. Temperature Setting

The temperature can be set in the
range of 15

O

C - 30

O

C.

4. Sleep

The facility to raise up the setting
temperature 1

O

C (in Cool mode)

for the purpose of comfort and
energy saving.

5. Operating Mode

Press MODE button to select
system operating modes. The air
conditioner can be put in 2 modes
(COOL and FAN) for cooling only
model. And 3 modes (COOL, HEAT
and FAN) for cooling/heating model.

6. Timer

The facility to turn on/off the air
conditioner is 15 hours in advance.

TIMER OFF

 To set timer off by

pressing TIMER button during air
conditioning is on, TIME LED will
blink and will show last hour time
setting in blinking light. Pressing
HOUR 

▲ 

or HOUR 

 to increase

or decrease hour digit (between 1
to 15 can be set).

TIMER ON 

Using same procedure

to set timer off except press TIMER
button during air conditioner is off.

7. Toggle 

O

C/

 O

F

The facility to change Temperature
Display from 

O

C to 

O

F or from 

O

F

to 

O

C. By pressing TEMP+ and

TEMP- button at the same time
for 5 seconds.

Wired Control

A

HOUR

TEMP

HOUR

Temperature

Display

Hour Setting

Button

Timer Button

Fan Button

Power Button

Temperature
Setting Button

Sleep Button

For Cooling/
Heating Model

Mode Button

TEMP

TIMER

COOL

FAN

HEAT

SLEEP

MODE

0

1

2

3

4

5

6

7

8

9

10

11

12

-2

O

C

-1

O

C

SET  POINT

START

NORMAL

SLEEP

HOUR

+1

O

C

+2

O

C

SLEEP  (COOLING  MODE)

By pressing SLEEP button, the unit will operate at SLEEP FUNCTION it will
automatically return to normal operation when the air-conditioner is switched
off and on again.

0

1

2

3

4

5

6

7

8

9

10

11

12

START

NORMAL

SLEEP

HOUR

SLEEP  (HEATING  MODE)

By pressing SLEEP button, the unit will operate at SLEEP FUNCTION it will
automatically return to normal operation when the air-conditioner is switched
off and on again.

-2

O

C

-1

O

C

SET  POINT

+1

O

C

+2

O

C

AW 02092023TRA

29/10/02, 2:51 PM

9

Black

Содержание CFEA 04 C0M1

Страница 1: ...M1 CFEA 20 C0M1 60 Hz Models Cooling Only CFEA 04 C0M2 CFEA 06 C0M2 CFEA 08 C0M2 CFEA 10 C0M2 CFEA 12 C0M2 CFEA 14 C0M2 CFEA 16 C0M2 CFEA 20 C0M2 Cooling Heating CFEA 04 CEM1 CFEA 06 CFM1 CFEA 08 CBM1...

Страница 2: ...and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery Notify the dealer at the same time The unit should be totally inspected within 7 days of delivery...

Страница 3: ...nts General Information 2 Control Operation 4 Wireless Remote Control 5 Wired Control 9 System Operation 10 Electronic Room Thermostat 12 Maintenance 13 Troubleshooting 14 Notes 15 AW 02092023TRA 29 1...

Страница 4: ...m is being controlled by the timer One Touch Control Switch A This button is used for adjusting operation without remote control unit This press switch is for selecting the system mode of operation FA...

Страница 5: ...ess the button again to stop operation 6 Temperature Setting Button TEMP Press this button to increase the set temperature TEMP Press this button to decrease the set temperature 7 FAN Button Press thi...

Страница 6: ...ither TEMP or TEMP button to set the desired room temperature Temperature set range is 15 O C to 30 O C Press FAN button to select any fan speed The FAN display will show LOW MED HIGH or AUTO accordin...

Страница 7: ...temperature or current time valve No setting is changed Press SEND or STOP buttons to transmit the signal to the air conditioner The set time will stop blinking The unit will stop automatically at se...

Страница 8: ...t and the supply air grille will automatically close LOUVER Operation The direction of the airflow can be controlled Press LOUVER button to adjust the angle of the blade to control the direction of th...

Страница 9: ...our time setting in blinking light Pressing HOUR or HOUR to increase or decrease hour digit between 1 to 15 can be set TIMER ON Using same procedure to set timer off except press TIMER button during a...

Страница 10: ...owerinterruption thecontrol will resume its operation with same setting parameters except those related to the time 3 Pre heat Post heat Heat Model The facility to prevent the fan coil blowing cold dr...

Страница 11: ...supply air grille can be adjusted manually Do not inspect or service the air conditioner while it is operating Turn off the power supply before doing any inspection or service work The power cord shou...

Страница 12: ...to OFF position to turn off the air condition 2 Fan Button Three fan speed high medium low can be selected by push the button to the desired position 3 Temperature Setting Temperature setting can be...

Страница 13: ...pushing down and pulling forward Remove each air filter frame from the return air grille 1 2 How to clean the air filter Wash away dust from the air filter with clean water or vacuum it with an electr...

Страница 14: ...ck whether there are sources of heat in the room cooling is less effective Check whether the return air grille or the supply air grille on the indoor unit and outdoor unit are blocked If they are bloc...

Страница 15: ...15 UNT SVU001 EN Notes AW 02092023TRA 29 10 02 2 51 PM 15 Black...

Страница 16: ...http www trane com An American Standard Company Literature Order Number UNT SVU001 EN 0701 Supersedes UNT SVU001 EN 0999 Stocking Location Bangkok Thailand 35 8 10130 Since The Trane Company has a pol...

Отзывы: