CXRC-SVX01J-EN
Startup and Shutdown
Startup
W
WA
AR
RN
NIIN
NG
G
L
Liiv
ve
e E
Elle
eccttrriicca
all C
Co
om
mp
po
on
ne
en
nttss!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w a
allll e
elle
eccttrriicca
all ssa
affe
etty
y p
prre
ecca
au
uttiio
on
nss
w
wh
he
en
n e
ex
xp
po
osse
ed
d tto
o lliiv
ve
e e
elle
eccttrriicca
all cco
om
mp
po
on
ne
en
nttss cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
W
Wh
he
en
n iitt iiss n
ne
ecce
essssa
arry
y tto
o w
wo
orrkk w
wiitth
h lliiv
ve
e e
elle
eccttrriicca
all
cco
om
mp
po
on
ne
en
nttss,, h
ha
av
ve
e a
a q
qu
ua
alliiffiie
ed
d lliicce
en
nsse
ed
d e
elle
eccttrriicciia
an
n
o
orr o
otth
he
err iin
nd
diiv
viid
du
ua
all w
wh
ho
o h
ha
ass b
be
ee
en
n p
prro
op
pe
errlly
y ttrra
aiin
ne
ed
d
iin
n h
ha
an
nd
dlliin
ng
g lliiv
ve
e e
elle
eccttrriicca
all cco
om
mp
po
on
ne
en
nttss p
pe
errffo
orrm
m
tth
he
esse
e tta
asskkss..
N
NO
OT
TIIC
CE
E
C
Co
om
mp
prre
esssso
orr D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w w
wiillll cca
au
usse
e tth
he
e
cco
om
mp
prre
esssso
orr tto
o o
op
pe
erra
atte
e iin
n a
a v
va
accu
uu
um
m a
an
nd
d rre
essu
ulltt iin
n
cco
om
mp
prre
esssso
orr d
da
am
ma
ag
ge
e..
N
Ne
ev
ve
err m
ma
an
nu
ua
alllly
y o
orr a
au
utto
om
ma
attiicca
alllly
y p
pu
um
mp
p d
do
ow
wn
n
ssy
ysstte
em
m b
be
ello
ow
w 7
7 p
pssiig
g..
N
NO
OT
TIIC
CE
E
C
Co
om
mp
prre
esssso
orr D
Da
am
ma
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss cco
ou
ulld
d rre
essu
ulltt iin
n
cco
om
mp
prre
esssso
orr d
da
am
ma
ag
ge
e..
K
Ke
ee
ep
p ccrra
an
nkkcca
asse
e h
he
ea
atte
errss o
on
n w
wh
he
en
ne
ev
ve
err rre
effrriig
ge
erra
an
ntt iiss
iin
n tth
he
e ssy
ysstte
em
m..
IIff ccrra
an
nkkcca
asse
e h
he
ea
atte
errss h
ha
av
ve
e n
no
ott b
be
ee
en
n o
on
n w
wiitth
h
rre
effrriig
ge
erra
an
ntt iin
n tth
he
e ssy
ysstte
em
m,, ttu
urrn
n tth
he
e ccrra
an
nkkcca
asse
e
h
he
ea
atte
errss o
on
n ffo
orr a
a m
miin
niim
mu
um
m o
off 2
24
4 h
ho
ou
urrss b
be
effo
orre
e
sstta
arrttiin
ng
g cco
om
mp
prre
esssso
orrss..
When wired properly, the unit cycles condenser fans in
response to compressor interlock or the IntelliPak
controller output. The IntelliPak controller reads
saturated refrigerant temperatures and cycles the fans
appropriately. Refer to the section,
.
Normal Unit Shut Down
The unit can be stopped by opening the unit power
supply disconnect switch. However, normally the unit
operation stops due to interruption of the cooling
demand signal by the circuit cooling relays. The CCRC/
CIRC condensing unit should be shutdown by first
shutting down the indoor evaporative cooling unit. By
stopping the indoor unit, the request for condensing
has been terminated, thus stopping all condenser fans.
The disconnect switch on the CCRC/CIRC unit power
supply should then be opened. By not shutting down
the evaporator unit first before the condenser unit
results in a high-pressure situation and should be
avoided if possible.
Seasonal Shut Down
If the unit will be inoperative for an extended period,
lock out unit operation by disconnecting the
compressor interlock circuits and opening and locking
the main power disconnect switch.
If desired, large amounts of liquid refrigerant can be
isolated and stored in the condenser by closing the
liquid line service valves and operating the
compressors to pump the refrigerant into the
condenser and then valving off the hot gas line near
the condenser coil.
Seasonal Startup
1. Inspect the interior of the unit for debris.
2. Check control panel wiring connections for
corrosion and proper security. Check control panel
door for proper weather seal.
3. Inspect condenser fans. Blades must be secure on
fan shaft and rotate freely.
4. Inspect coil for obstructions and cleanliness. Clean
coil if required.
5. Inspect low ambient dampers. Damper blades must
be properly aligned, free from obstructions and
operate freely. You may have to disconnect
actuator linkage to inspect damper movement.
6. Close unit power supply disconnect switch.
7. Allow 24 hours of crankcase operation before
starting compressors. Crankcase heaters are
energized whenever the unit disconnect is closed
and the compressors are off.
The unit should now operate properly in response to
cooling demand at the system thermostat.