WSHP-SVX01Y-EN
63
Table 45.
Economizer part numbers (continued)
GEH Unit 60 Hz
GEH Unit 50 Hz
Waterside
Economizer
Part Number
035-042
030-036
4476 1420 0001
048-060
042-060
4476 1421 0001
Table 46.
Economizer part numbers
GEVG Unit 60 Hz
Waterside Economizer
Part Number
006-012
WSHPECN00001
015–018
WSHPECN00002
024–030
WSHPECN00003
036–042
WSHPECN00004
048–060
WSHPECN00005
Waterside Economizer Installation for
GEH and GEV 6 to 25 Ton Models
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
1. Remove the filter frame from the unit.
2. Remove the waterside service panel from the unit.
3. Remove the control box service panel from the unit.
4. Remove the economizer and miscellaneous
mounting parts from it’s packaging.
5. GEV ONLY: Mount the economizer support angle
(4475 1637 0100) found in the economizer
packaging in the same holes of the return air filter
frame removed in Step 1. The support angle screws
into the unit roof.
6. GEV ONLY: Hang the economizer assembly from
the economizer support angle mounted in Step 5.
7. Secure the economizer to the unit using the four
plates (4475 1630 0100) found in the economizer
packaging. Two plates should be applied to each
economizer side. GEV ONLY: Secure the bracket on
the bottom of the economizer cabinet to the unit
compressor compartment center post.
8. Install the field portion of the water piping and the
3-way valve together.
9. Verify the control board for the waterside
economizer is located inside the unit. The
temperature rating of this board is factory set to
55ºF.
10. Thread the economizer’s entering water
temperature sensor (4RT1) through the water-in
line of the water-source heat pump upstream from
the valve. This sensor is used by the economizer’s
3-way valve to determine if water flow should be
directed through the waterside economizing coil.
11. Tie wrap the thermistor to the water line (supply
side) upstream of the water pipe to the economizer.
The thermistor must be situated so that the
thermistor is capable of reading the actual entering
water temperature regardless of the economizer’s
on or off situation.
12. Insulate the thermistor with tubing insulation.
13. Tie wrap each end of the tubing insulation to
prevent air filtration. The tie wraps and insulation
are located in a bag and shipped inside of the unit.
14. Route the factory wire harness through the low
voltage hole of the heat pump to the 3-way valve’s
wire harness.
15. Connect the factory installed wire harness to the
wire harness supplied with the 3-way valve.
16. Bundle excess valve wire, and wire tie the bundle
neatly.
17. Install control side service panel to the heat pump.
18. Install the unit filter frame to the economizing inlet.
19. Insulate the economizing piping package with field
supplied pipe insulation. Insulating the piping will
help stop condensation from forming on the pipe.
N
No
otte
ess::
•
Trane does not provide insulation on the
economizing piping package. This insulation
must be field provided and field installed.
•
Trane does not provide condensate
overflow protection of the waterside
economizer. This must be field provided and
field installed.
20. Install waterside service panel to the heat pump.
The economizer condensate line must be trapped prior
to the unit’s drain line. This helps prevent air from
being sucked through the drain line causing
Содержание Axiom GEH-E035
Страница 116: ...116 WSHP SVX01Y EN Figure 83 GEH_V 6 to 25 tons deluxe 24V 460V 60 Hz 3 ph W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 117: ...WSHP SVX01Y EN 117 Figure 84 GEH_V 6 to 25 tons Tracer ZN524 460V 60 Hz 3 ph W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 118: ...118 WSHP SVX01Y EN Figure 85 GEHE 0 5 to 1 5 tons UC400 W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 119: ...WSHP SVX01Y EN 119 Figure 86 GEHE 2 to 5 tons UC400 W Wi ir ri in ng g D Di ia ag gr ra am ms s...
Страница 122: ...122 WSHP SVX01Y EN N No ot te es s...
Страница 123: ...WSHP SVX01Y EN 123 N No ot te es s...