64
Part 5 Outdoor Units
5.1 Feature
TRANE Model
4TXM2318BF300AA
4TXM2324BF300AA
Power supply
V-ph-Hz
220-1-50(60)
220-1-50(60)
Max. IDU combination
3
3
Max. input consumption
W
2,500
2,600
Max. input current
A
10.9
11.5
Cooling
Capacity
Btu/h
18,000
24,000
Capacity
W
5,200
7,000
Input
W
1,500
2,000
Rated Current
A
6.7
8.7
EER
W/W
3.60
3.40
Heating
Capacity
Btu/h
19,000
24,000
Capacity
W
5,860
7,000
Input
W
1,500
2,000
Rated Current
A
6.7
8.7
COP
W/W
3.6
3.4
Compressor
Model
SNB140FULMC-L3
SNB140FULMC-L3
Type
Twin Rotary (DC inverter)
Twin Rotary (DC inverter)
Brand
MELCOM
MELCOM
Capacity
Btu/h
15,000
15,000
Input
W
1,300
1,300
Rated current(RLA)
A
4.4
4.4
Locked rotor Amp(LRA)
A
18.4
18.4
Thermal protector position
INTERNAL
INTERNAL
Capacitor
μF
/
/
Refrigerant oil
ml
600
600
Outdoor fan
motor
Model
ZWK511B500045
ZWK511B500045
Qty
1
1
Input
W
130
130
Capacitor
μF
/
/
Speed
r/min
700
700
Outdoor coil
Number of rows
1
2
Tube pitch(a) × row
pitch(b)
mm
25
21×18.18
Fin spacing
mm
1.5
1.4
Fin type
Hydrophilic aluminium
Hydrophilic aluminium
Tube outside dia.and type
mm
TP2M / 9.52
TP2M /7
Coil length × height ×
width
mm
911×650×21.65
950×651×36.36
Number of circuits
2
5
Содержание 4TXM2318BF300AA
Страница 102: ...100 PCB 0151800611 4MXE2309BF0W0AA 4MXE2312BF0W0AA...
Страница 116: ...114 PCB 0151800364D Power Module 0011800377C...
Страница 117: ...115 Power Module 0011800377AJ PCB 0151800364C...
Страница 153: ...151 Screw 0010600325 Terminal block 0010452210E Connection cable 0150400330 Install the connection cable like this way...