Installing Drain Hoses and Coolant Overflow Hose –
DRC Applications
Drain and Overflow Hose Installation
1. Evaporator drain hoses should run down from the unit with no kinks or sharp bends.
2. Secure each hose to the front wall with clamps and screws as shown.
3. Cut off excess hose and attach check valves with supplied bandwraps.
IIm
mp
po
orrtta
an
ntt:: Upper clamp location varies by individual application while lower clamps should be installed 127 mm (5.00
in.) up from the bottom of the drain valves and not so tight as to restrict water drainage.
4. Coolant overflow hose should run straight down the wall with no kinks or bends.
5. Secure the overflow hose to the evaporator drain hose with supplied bandwraps as shown.