Trane Technologies DRV03113 Скачать руководство пользователя страница 9

BAS-SVN029C-EN

9

W

WA

AR

RN

NIIN

NG

G

H

Ha

azza

arrd

do

ou

uss V

Vo

olltta

ag

ge

e w

w//C

Ca

ap

pa

acciitto

orrss!!

F

Fa

aiillu

urre

e tto

o d

diisscco

on

nn

ne

ecctt p

po

ow

we

err a

an

nd

d d

diisscch

ha

arrg

ge

e cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n

d

de

ea

atth

h o

orr sse

erriio

ou

uss iin

njju

urry

y..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e d

diisscco

on

nn

ne

eccttss a

an

nd

d d

diisscch

ha

arrg

ge

e a

allll m

mo

otto

orr

sstta

arrtt//rru

un

n cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e

tth

he

e p

po

ow

we

err cca

an

nn

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d.. F

Fo

orr v

va

arriia

ab

blle

e ffrre

eq

qu

ue

en

nccy

y d

drriiv

ve

ess o

orr o

otth

he

err

e

en

ne

errg

gy

y sstto

orriin

ng

g cco

om

mp

po

on

ne

en

nttss p

prro

ov

viid

de

ed

d b

by

y T

Trra

an

ne

e o

orr o

otth

he

errss,, rre

effe

err tto

o tth

he

e a

ap

pp

prro

op

prriia

atte

e

m

ma

an

nu

uffa

accttu

urre

err’’ss lliitte

erra

attu

urre

e ffo

orr a

allllo

ow

wa

ab

blle

e w

wa

aiittiin

ng

g p

pe

erriio

od

dss ffo

orr d

diisscch

ha

arrg

ge

e o

off cca

ap

pa

acciitto

orrss.. V

Ve

erriiffy

y

w

wiitth

h a

a C

CA

AT

T IIIIII o

orr IIV

V v

vo

ollttm

me

ette

err rra

atte

ed

d p

pe

err N

NF

FP

PA

A 7

70

0E

E tth

ha

att a

allll cca

ap

pa

acciitto

orrss h

ha

av

ve

e d

diisscch

ha

arrg

ge

ed

d..

F

Fo

orr a

ad

dd

diittiio

on

na

all iin

nffo

orrm

ma

attiio

on

n rre

eg

ga

arrd

diin

ng

g tth

he

e ssa

affe

e d

diisscch

ha

arrg

ge

e o

off cca

ap

pa

acciitto

orrss,, sse

ee

e P

PR

RO

OD

D--S

SV

VB

B0

06

6*

*--

E

EN

N..

N

No

otte

e:: For additional information regarding the safe discharge of capacitors, see PROD-SVB06x-

EN or PROD-SVB06x-FR.

Remove the Power Supply Wiring

Disconnect the following power supply and control wires from each VFD. The following
instructions relate to either the IntelliPak II, CGAM or RTAC VFD.

1. Disconnect power supply wires from VFD connection points 91, 92, 93 (L1, L2, L3

respectively).

2. Disconnect output power wires from VFD connection points 96, 97, 98, 95 (T1, T2, T3, GND

respectively).

Remove the Control Wiring

Complete the following steps to remove the control wiring.

1. Disconnect all control wires from the TR1 VFD itself and note the connection point numbers.

The TR1 and TR170 have the same connection point numbers. See the following table, which
applies to IntelliPak II, CGAM, and RTAC drives except as noted, for common control wiring
and their connection point numbers.

Table 1. Typical control wires to remove from the TR1 and reinstall on the TR170

Control Wiring

Intellipak II

CGAM

RTAC

(a)

VFD

Description

Fan 1

Fan 2

Fan 1

Fan 2

Fan 1

Fan 2

Connection
Point

710B

712B

549B

555B

151A

651A

12

+24V

711B

713B

550B

556B

152A

652A

18

Digital Input
(Run)

710C

712C

Not Used

27

Digital Input
(Coast)

584C

586C

807B

809B

119A

122A

53

Analog Input
(0-10VDC)

585C

587C

808B

810B

128A

129A

55

GND

Not Used

803B

805B

120A

123A

1

Relay 1 -
Common

804B

806B

121A

124A

3

Relay 1 -
Normally
Closed

(a)

Wire numbers shown only for RTAC with 2 VFDs.

R

Re

em

mo

ov

viin

ng

g tth

he

e E

Ex

xiissttiin

ng

g V

VF

FD

D a

an

nd

d C

Co

om

mp

po

on

ne

en

nttss

Содержание DRV03113

Страница 1: ...ly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stic...

Страница 2: ...our customers and the air conditioning industry All technicians who handle refrigerants must be certified according to local rules For the USA the Federal Clean Air Act Section 608 sets forth the requ...

Страница 3: ...iz ze ed d e el le ec ct tr ri ic ca al l c co on nt ta ac ct t a ar rc c o or r f fl la as sh h t te ec ch hn ni ic ci ia an ns s M MU US ST T p pu ut t o on n a al ll l P PP PE E i in n a ac cc co...

Страница 4: ...nstall the TR170 Drive 11 Wire the Power Supply and Controls to the TR170 11 Installing the Drive On a Four Compressor Unit or Circuit 1 of a Three Compressor Unit RTAC 11 Set the VFD Programming Para...

Страница 5: ...an drives The number of drives will match the number of compressors For example a three compressor RTAC will have three condenser fan drives The installation instructions in this manual are divided in...

Страница 6: ...losure for Intellipak II CGAM and RTAC units as shown in the following figures 2 Identify the correct VFD for replacement The IntelliPak II rooftops with low ambient option always have two condenser f...

Страница 7: ...iguration Figure 4 Typical CGAM 70 ton panel illustration and low ambient option VFD location Low Ambient Option Condenser Fan VFD R Re em mo ov vi in ng g t th he e E Ex xi is st ti in ng g V VF FD D...

Страница 8: ...guration Figure 6 Typical RTAC 200 ton panel illustration and low ambient option VFD location Low Ambient Option Condenser Fan VFD R Re em mo ov vi in ng g t th he e E Ex xi is st ti in ng g V VF FD D...

Страница 9: ...P PA A 7 70 0E E t th ha at t a al ll l c ca ap pa ac ci it to or rs s h ha av ve e d di is sc ch ha ar rg ge ed d F Fo or r a ad dd di it ti io on na al l i in nf fo or rm ma at ti io on n r re eg ga...

Страница 10: ...e e u un ni it t m mu us st t b be e c ca ap pa ab bl le e o of f s su up pp po or rt ti in ng g t th he e e en nt ti ir re e w we ei ig gh ht t o of f t th he e u un ni it t L Li if ft ti in ng g c c...

Страница 11: ...may be found in Wiring Diagram Matrix p 21 Print a copy from e Library if accessible or contact the local Trane representative to obtain a copy 1 Reconnect power supply wires to VFD connection points...

Страница 12: ...Ar rc c F Fl la as sh h R Re eq qu ui ir re ed d F Fa ai il lu ur re e t to o w we ea ar r a ap pp pr ro op pr ri ia at te e P PP PE E c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r...

Страница 13: ...erify Parameter 5 12 is set per Table 4 p 14 Table 5 p 15 and Table 6 p 16 for the given Product you are installing the drive into parameter 5 12 will be set to either Coast Inverse or No Function dep...

Страница 14: ...s to all parameters ALWAYS use this method Table 4 TR170 VFD drive parameter RTAC Parameter Number Parameter Description RTAC Setting Units 0 03 Regional Settings North America for 60 Hz International...

Страница 15: ...parameters Ipak II Parameter Number Parameter Description Ipak II Setting Units 0 03 Regional Settings North America for 60 Hz International for 50 Hz 0 06 Grid Type Depends on Grid Type 0 40 Hand on...

Страница 16: ...ing table defines the complete set of parameters for the TR170 VFD drives used in condenser fan applications on CGAM products Table 6 TR170 VFD drive parameters CGAM Parameter Number Parameter Descrip...

Страница 17: ...oduction 50Hz for Charmes production Otherwise set for maximum speed rating of motor fan Copying Parameters to Multiple Drives If you are installing multiple drives the drive LCP local control panel c...

Страница 18: ...sources TGE Online Help Tracer Ensemble Online Help Tracer Ensemble User Guide BAS SVU09 Tracer SC Online Help Tracer TU Online Help I In ns st ta al ll li in ng g T TR R1 17 70 0 V VF FD D a an nd d...

Страница 19: ...plications an additional heater blanket as well as applicable wiring and accessories may also need to be installed to make heater blankets operational The following two diagrams show installation of h...

Страница 20: ...in IPak II 460 volt option See Wire the Power Supply and Controls to the TR170 p 11 for the procedure used to wire the power supply and controls to the TR170 I In ns st ta al ll li in ng g T TR R1 17...

Страница 21: ...150 TON WITH EXHAUST OR RETURN VFD AND WITH LOW AMBIENT 2313 0850 SCHEMATIC POWER 120 150 TON WITH SUPPLY AND EXHAUST OR RETURN VFD W LOW AMBIENT 2313 0839 SCHEMATIC POWER 90 105 TON STANDARD WITH LOW...

Страница 22: ...py Table 8 TR170 VFD CGAM wiring schematics and connection diagrams Wiring Diagram Number Description 2309 2075 SCHEMATIC CGAM S V W N No ot te e Wiring diagrams are available via e Library if accessi...

Страница 23: ...BAS SVN029C EN 23 N No ot te es s...

Страница 24: ...For more information please visit trane com or tranetechnologies com Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications w...