Electrical Connections 

Main Power to the Machine Connections 

The 3 phase 480 volt (432 to 528 V is acceptable) is connected to L1, L2 and L3 at the main power switch inside the 
electrical box. Connect the ground wire as shown in the figure 10.   

 

Figure 9 

 Connect the Ground Wire 

Machine Grounding 

It is strongly recommended that the machine be earth grounded. A dedicated copper rod 8 feet or so in length 
should be driven into the ground near the VMCsi. A ground wire should then be run from the location shown in 
figure 9. The copper wire should exit the electrical cabinet in the mid left hand side as shown in figure 10. Make sure 

the foam where the copper wire goes through seals the cabinet from external debris. The wire should be 6 gage in 
size.  

 
 
 
 
 

 

 
 
 
 

 
 

Содержание VMC14si

Страница 1: ...ion and service manual for additional information Make sure to follow our grounding recommendations The machine must have air hooked up We strongly recommend that a water separator or air dryer be installed upstream of the VMCsi air supply Space Weight Floor area W x L 226 25 x 157 Height 106 min 119 25 max Footprint W x L coolant tank in place 180 x 126 50 Net approx Weight 17 600 lbs Shipping ap...

Страница 2: ...TRAK Machine Tools Site Preparation Guide TRAK VMC14si F16467 65 Rev 9 10 2021 Page 2 of 7 Figure 1 Front View of Machine Figure 2 Side View of Machine ...

Страница 3: ...TRAK Machine Tools Site Preparation Guide TRAK VMC14si F16467 65 Rev 9 10 2021 Page 3 of 7 Figure 3 Top View of Machine Figure 4 Lifting the VMCsi ...

Страница 4: ...TRAK Machine Tools Site Preparation Guide TRAK VMC14si F16467 65 Rev 9 10 2021 Page 4 of 7 Figure 5 Lifting the VMCsi Figure 6 Leveling Pad Locations ...

Страница 5: ...of 7 If you would like to lift the machine with a crane the following figures show the lifting points Note Brackets that attach to the two column casting and shown in figure 8 are not provided with the machine Figure 7 Lifting Machine with Straps Figure 8 Lifting Machine on Top of Column ...

Страница 6: ... the figure 10 Figure 9 Connect the Ground Wire Machine Grounding It is strongly recommended that the machine be earth grounded A dedicated copper rod 8 feet or so in length should be driven into the ground near the VMCsi A ground wire should then be run from the location shown in figure 9 The copper wire should exit the electrical cabinet in the mid left hand side as shown in figure 10 Make sure ...

Страница 7: ...TRAK Machine Tools Site Preparation Guide TRAK VMC14si F16467 65 Rev 9 10 2021 Page 7 of 7 Figure 10 Exit Location for Ground Wire to Copper Rod ...

Отзывы: