- 16 -
e) Press OK to save the current setting and the option will be highlighted.
f) Press MENU to cancel setting and return to info display
4.1.14 Set PIR Triggering Interval Time
This parameter means that how long the PIR (Passive Infrared motion sensor)
will be disabled after each triggering in ON mode. During this time the PIR of the device
will not react to the motion of humen (or animals). The minimum interval is 0 second, it
means the PIR works all the time and
media is taken almost continously
. The maximum
interval is 1 hour, it means the PIR will be disabled for 1 hour after each triggering. The
default value is 1 minute. Press LEFT or RIGHT to decreases or increases the value by 5
second or 1 minute.
a) Press MENU to display the setting menu.
b) Press UP or DOWN to select Interval.
c) Press RIGHT to enter in to the interval setting.
d) Press UP or DOWN to select time interval.
e) Press OK to save the current setting and the option will be highlighted.
f) Press MENU to cancel setting and return to info display.
4.1.15 Set PIR Sensitivity
This parameter defines the sensitivity of the PIR. There are three parameters: High,
Normal, and Low. The default value is “Normal”. The higher degree indicates that the Camera
is more easily triggered by motion, taking more pictures or recording more videos. it is
recommended to use high sensitivity indoors or in an environment with little interference,
and to use lower sensitivity for outdoor or environment with lots of Interference like hot wind,
smoke, near window etc. Furthermore, the sensitivity of the PIR is strongly related to the
temperature. Higher temperature leads to lower sensitivity. Therefore it is suggested to set a
higher sensitivity for high temperature environment.
The following shows how to set PIR sensitivity as Low provided that the previous option
is Normal.
a) Press MENU to display the setting menu.
b) Press UP or DOWN to select Sense Level.
c) Press RIGHT to enter selection
d) Press UP or DOWN to select “ HIGH” , “ MIDDLE” , “LOW”.
e) Press OK to save the current setting and the option will be highlighted.
f) Press MENU to cancel setting and return to info display.
4.1.16 Set Timer
This parameter defines a certain time lapse in a day when The Camera can be triggered.
In the rest of the time the device is shut off. The effective value of the hour ranges
from 0 to 23 while the minute ranges from 0 to 59.
Distance
DELAY