AC Power
AC Power
The SafePace 550 sign is equipped to accept 100-240 volts of AC power. For these signs (standard model),
the regulated power supply comes already pre-wired, and your sign is ready to operate once it is mounted
and wired to the incoming power supply. The Line (BLACK) and Neutral (WHITE) wires of the incoming
power supply should be connected to the marked terminals. The Ground wire should be connected to the
GREEN/YELLOW terminal (see
).
Figure 12: AC power supply terminal block
Figure 13: Close-up view of AC power
connectors
W
ARNING
:
ELECTRICAL SHOCK HAZARD. To avoid serious injury or even death, all electrical wiring
should be performed by a qualified and professional electrician in accordance with local electrical
codes. Mishandling of electrical wiring may also result in damage to the unit and may void product
warranty.
W
ARNING
:
Should you need to drill holes in the sign for the AC power wiring, drill from the inside/out
as opposed to outside/in. This is to reduce the possibility of metal filings damaging the internal
components of the sign.
W
ARNING
:
It is vitally important, whenever you close the sign, that you close and lock
all
of the latches
properly to avoid water infiltration as this could damage the sign and void your warranty.
SafePace® 550 Installation Manual
p. 18