www.trafag.com

    

 8380 DPC, 8381 DPS

Pressure switch with display

Technical specification

Mounting torque: 

15 ... 20 Nm

Operating temperature: 

– 25°C ... +85°C

Media temperature: 

– 25°C ... +85°C

Protection: IP67

Display pressure unit: 

bar, psi, MPa, kPa, m WC, mm WC

Switching current: 

Max. 0.5 A per switching output

Parametrisation: 

With 3 buttons and menu navigation or via NFC - Smartphone App

Instructions

2

3

5

4

1

3 2

1

4

*

)

   Provided female connector is mounted according to instructions

Electrical connection

Type 838X.XX.XXXX   

S/N YYYYYY-ZZZ 

|

 16/16   

 

Range  -1...9 bar-G 

|

 max.: 20 bar

Us     (1) 15...30V DC 

|

 Us      (3) 

|

 Out (2) 

|

 SP1 (4) 

|

 SP2 (5)

Measuring range

Type code

Serial number

Max. overpressure

Supply positive

Supply voltage

Switching 

output

Manufacturing date (W/Y)

Type label description

Pin assignment

Output signal / supply voltage

Output I

SUPPLY

 U

SUPPLY

 

4 ... 20 mA 

≤ 30 mA 

15 ... 30 VDC

0 ... 10 VDC 

≤ 30 mA 

15 ... 30 VDC

0 ...   5 VDC 

≤ 30 mA 

15 ... 30 VDC

1 ...   6 VDC 

≤ 30 mA 

15 ... 30 VDC

SWITZERLAND

Ingress Protection

IP67*

)

IP67*

)

Designation

M12x1

5-pole

M12x1

4-pole

Type code

838X

.XX.XXXX.

35

838X

.XX.XXXX.

32

Pin configuration

Analogue 

output

Sensor Master by Trafag AG

Содержание 8380 DPC

Страница 1: ...g to instructions Electrical connection Type 838X XX XXXX S N YYYYYY ZZZ 16 16 Range 1 9 bar G max 20 bar Us 1 15 30V DC Us 3 Out 2 SP1 4 SP2 5 Measuring range Type code Serial number Max overpressure Supply positive Supply voltage Switching output Manufacturing date W Y Type label description Pin assignment Output signal supply voltage Output ISUPPLY USUPPLY 4 20 mA 30 mA 15 30 VDC 0 10 VDC 30 mA...

Страница 2: ...of the measuring equipment P U I Us Shield Out Out analogue SP1 SP2 Us The use of a shielded cable is recommended ü t P ON OFF ON OFF Fno Fnc FL FH t P ON Hno OFF ON Hnc OFF dS dr rP SP t P ON Hno OFF rP SP ON Hnc OFF Hysteresis Window Delay P US US I SP1 SP2 RL US earth Connection of loads to switching output ...

Страница 3: ...X XX51 XX XX XX 11 14 5 13 5 Ø 5 05x3U M5x7 Ø 29 5 M14x1 5 DIN6149 2 SW27 838X XX XX31 XX XX XX 12 5 14 20 14 5 Ø 21 M5 G1 4 838X XX XX10 XX XX XX 7 16 20UNF DIN3866 13 5 838X XX XX18 XX XX XX 9 2 3 Ø 29 5 M5x7 7 16 20UNF SAE4 J1926 SW27 838X XX XX42 XX XX XX 7 16 20UNF SAE J512 Ø20 8 6 1 5 838X XX XX24 XX XX XX 28 5 14 3 11 5 G1 2 Seal DIN3869 DIN3852 E M 5x7 Ø 29 5 SW27 838X XX XX41 XX XX XX Dim...

Страница 4: ...ut end point Damping analogue output rise time 10 90 nominal pressure 0 01 3 00 s Display rotate no yes 180 Display mode actual highest lowest off act 1 decimal act 2 dec act 3 dec Display update rate 1 2 5 20 Hz Diagnostic mode Sampling time for logger 0 1 999 9 s off 0 Access code 4 digit code Factory use By pressing simultaneously the menu will return to the base dis play or automatically after...

Отзывы: