16
A3380002.en_teil2
Exchange of the punch, the dies and the cutter
•
Disassemble the ejector and the ejector screw.
•
Unscrew the strap stop and pull the upper ejector together with the strap stop out of the tool.
•
Unscrew the side plate and disassemble both guide gibs.
•
Slightly lift the sealing lever and remove bearing pick-up attachment, link and the die- and cutter piston from
the sealing body.
•
Clean all parts and replace the worn ones.
•
Fitting in opposite order.
Important!
Bearing areas and guides have to be greased.
The fastening screws for the punch and the dies have to be secured with LOCTITE 222.
Punch
Strap stop with upper ejector
Die and cutter piston with link
Bearing pick-up attachment
Guide gibs
Cutter
Ejector
Dies left and right
Ejector screw