Tradesman MAGNESIUM 8520 Скачать руководство пользователя страница 3

AIR SUPPLY AND CONNECTIONS 

 
 

 

The compressed air power source shall be pressure-regulated.  The regulated 

pressure must not exceed the maximum air pressure marked on the tool.  If a 

regulator fails, the pressure delivered to the tool must not exceed 1.5 times the 

maximum air pressure, or 180 PSI, whichever is greater. 

 

Pressure regulators shall be used to limit the air pressure supplied to the tool.  

Regulators shall be set at an operating pressure which is lower than or equal to the 

tool manufacturer’s specified maximum air pressure. 

 

Air supply hoses shall have a minimum working pressure rating equal to or greater 

than the pressure from the power source if a regulator fails, or 120 PSI, whichever is 

greater. 

 

Tools shall be fitted with a fitting or hose coupling on or near the tool in such a manner 

that all compressed air in the tool is discharged at the time the fitting or hose coupling 

is disconnected.  

 

 

Many air tool users find it convenient to use an 
oilier to help provide oil circulation throughout 
the tool and to increase the efficiency and useful 
life of the tool. Check oil level in the oilier daily. 

 

 

Many air tool users find it convenient to use a 
filter to remove liquids and impurities which can 
rust or wear internal parts of the tool. A filter can 
also increase the efficiency and usefulness 
of the tool. The filter must be checked on a daily 
basis, and if necessary, drained. 

 

 

For better performance, install a 3/8” quick 
connector (1/4” NPT threads) with an inside 
diameter of .315” on your tool and a 3/8” quick 
coupler on the air hose. 

 
 

The following illustration shows the correct mode of connection to the air supply 
system which will increase the efficiency and useful life of the tool. 

 
 
 
 
 
 
 
 
 
 
 

TESTING THE SAFETY TRIP MECHANISM 

 

Never point any operational fastener driving tool at yourself or at any other 
person. 

 

 

Disconnect the air supply from the tool. 
 
 
 
 
 

 

Insert a stick of fasteners into the magazine.  See section 
on “Loading Fasteners Into Stapler”. 
 
 
 
 

 

Press down on workpiece and release the contact safety 
trip mechanism.  Verify there is no binding, sticking or 
jamming of this mechanism. 

 
 
 

 

Reconnect the air supply to the tool. 
 
 
 
 
 

 

Depress the contact safety trip mechanism against the 
workpiece without pulling the trigger. The tool must not 
cycle. Never use the tool if a cycle occurs. 
 
 

 

Hold the tool clear of the workpiece. The contact safety trip 
mechanism should return to its original down position. Pull 
the trigger. The tool must not cycle. Do not use the tool if a 
cycle occurs. 
 
 

 

To complete the testing procedures, depress the contact 
safety mechanism against the workpiece and pull the 
trigger, the tool must cycle. 
 

 

4

5

Содержание MAGNESIUM 8520

Страница 1: ...ves you specific legal rights You also have implied warranty rights In the event you have a problem with this warranty service or performance you may be able to go to Small Claims Court a State Court or a Federal District Court How to Obtain Replacement Parts and Service The merchandise you have purchased from us has been carefully engineered and manufactured under POWER TOOL SPECIALISTS rigid qua...

Страница 2: ... at yourself or at any other person Read and understand tool labels and manual Failure to follow warnings could result in DEATH or SERIOUS injury Operators and others in work area MUST wear safety glasses with side shields Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing NEVER point tool at yourself or others in work area The employer is responsible for ensuring...

Страница 3: ... can rust or wear internal parts of the tool A filter can also increase the efficiency and usefulness of the tool The filter must be checked on a daily basis and if necessary drained For better performance install a 3 8 quick connector 1 4 NPT threads with an inside diameter of 315 on your tool and a 3 8 quick coupler on the air hose The following illustration shows the correct mode of connection ...

Страница 4: ... to operate between 70 120 PSI Lower pressure below 70 PSI will reduce performance of the tool while higher air pressure over 120 PSI raises the performance of the tool beyond its rated capacity and could cause serious damage to the tool and the user Most applications will only require the minimum air pressure However larger fasteners and harder woods may require air pressure in the upper range TE...

Страница 5: ...the hose has a rated working pressure exceeding 200 PSI 13 8 bar 4 Load the fasteners into your tool following the instructions of Loading The Fastener in this manual 5 Test for proper fastener penetration by driving staples into a sample piece of wood If the fasteners do not achieve the desired penetration adjust the air pressure to a higher setting until the desired penetration is achieved Do no...

Страница 6: ... DEATH OR SERIOUS PERSONAL INJURY MAKE SURE TO DRY THE TOOL THOROUGHLY AFTER CLEANING AND BEFORE OPERATING THE TOOL AGAIN 1 Disconnect the air supply from the tool 2 When removing tar buildup from the nosepiece of the tool do not allow solvent to get into the cylinder or damage may occur After cleaning dry off the tool completely EXHAUST PORT ADJUSTMENT The exhaust port may be rotated 360 to direc...

Страница 7: ...ADJUST WHEEL 1 025Q PUSHER PIN 2 24ZQ HEX SOC COUNTERSUNK HD SCREW M5X0 8 10 1 025S NAILER PLATE 1 259Y GUIDE PLATE 1 025U PNEUMATIC AIR TOOL OIL 1 25BL HOOK ASSEMBLY 1 026C QUICK CONNECTOR 1 25C0 LABEL 2 026N WARNING LABEL 1 25FS QUICK CONNECTOR CAP 1 027Y LABEL 1 25L7 NO MAR TIP 1 02F8 CAUTION LABEL 1 25MP COMPRESSION SPRING 1 0J3M HEX WRENCH 3 57 1 25MV DRIVER ASSEMBLY 1 0JC7 SPRING PIN 2 5 14 ...

Страница 8: ...NOTES NOTES 15 14 ...