Trade-wind VSL430-BF Скачать руководство пользователя страница 2

 

 
Item No. 0BL-00-012     Revised 09/19/17    Copyright © 2017 Universal Metal Industries, Inc.                       Proverbs 22:29                   Page 2 

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambe’). 

 

c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or filter. 

 

d) Use proper pan size.  Always use cookware appropriate for the size of the surface element.

 

 
 

WARNING!  TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A 

RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: 

 

a)  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner.  BE CAREFUL 
TO PREVENT BURNS.  If the flames do not go out immediately, EVACUATE AND CALL THE FIRE 
DEPARTMENT. 

 

b)  NEVER PICK UP A FLAMING PAN—YOU MAY BE BURNED.  

 

c)  DO NOT USE WATER, including wet dishcloths or towels.  A violent steam explosion will result.  

 

d)  Use an extinguisher ONLY if: 

1.  You know you have a Class ABC extinguisher and you already know how to operate it.  
2.  The fire is small and contained in the area where it started.  
3.  The fire department is being called.  
4.  You can fight the fire with your back to an exit.  
 
 

Recommendations: 

 

1.  Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.  

Locate the cooking area for minimum cross drafts-away from doors and windows, when possible.    

2.  Ducts must be of adequate size and duct runs should be as short as possible.  Where turns are necessary, 

keep turning radius as large and as smooth as possible. 

3.  The ducting must be air tight.  Use a minimum of 2 sheet metal screws at every duct joint.  Then, seal the duct 

joints with high quality duct tape. 

4.  Do not use this unit with any solid-state speed control device. 
5.  This unit must be grounded. 

 

INSTALLATION INSTRUCTIONS 

 
           WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 
           PERSONS, OBSERVE THE FOLLOWING: 

 

a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction codes and standards. 

 

b) Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel 
burning equipment to prevent back drafting.  Follow the heating equipment manufacturer's guidelines and safety 
standards such as those published by the National Fire Protection Association (NFPA) and the American Society 
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. 

 

c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

 

d) Ducted fans must always be vented to the outdoor.  

 
WARNING -- TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. 

 

 
CAUTION –

To reduce the risk of fire and to properly exhaust air, be sure to duct air outside –

 

              Do not vent exhaust air into spaces within walls, ceilings, cabinets or into attics, crawl spaces, or garages. 
 

 

Содержание VSL430-BF

Страница 1: ...d for future reference WARNINGS Must be followed carefully to avoid personal injury IMPORTANT Must be followed carefully to avoid damage or incorrect installation TIPS Contain helpful information to f...

Страница 2: ...possible 2 Ducts must be of adequate size and duct runs should be as short as possible Where turns are necessary keep turning radius as large and as smooth as possible 3 The ducting must be air tight...

Страница 3: ...duct silencer Given the high performance of Trade Wind In Line Blowers it is highly recommended that the blower NOT be attached directly to the liner or in a chase immediately above the liner unless...

Страница 4: ...the back sides or top We recommend at least six equally spaced screws per liner three screws along the back top or back side panel and three screws on the front top immediately next to the light bar w...

Страница 5: ...to improve efficiency Always use lids on cookware to retain heat and moisture Minimize the amount of liquid used to cook food Select cookware of proper size material and construction for the cooking...

Страница 6: ...either in line or roof top If the ventilator is rated in watts rather than amps divide the watts by 120 and this will give you the amperage rating The Trade Wind liner without the internal motor is su...

Страница 7: ...product that has been subject to misuse negligence accident or installation inconsistent with the recommended Trade Wind Installation Instructions and Trade Wind Best Practices Guidelines Product s u...

Страница 8: ...cted to one another Where possible always include at least 15 inches of straight pipe between fittings 3 Duct Pipe and Fitting Sizes See Duct Sizing Chart and Area Calculations Section for more detail...

Страница 9: ...ted tightly wrapped Aluminum Foil Metal Duct Tape on all connections and physically view and test the damper blades to make certain they are opening and closing correctly Make sure that the damper bla...

Страница 10: ...he roof cap or wall cap may be properly sized roof caps or wall caps with built in dampers must be made so that when the damper is fully open the actual open area of the final air path is equal to or...