Trade-wind VSL430 BF Скачать руководство пользователя страница 4

 

Item No. 0BL-00-012     Revised 07/19/2010    Copyright © 2008 Universal Metal Industries, Inc.                                   Page 4 

 

In-Line & Remote Ventilators, Duct Silencers, Dampers and Ducting  

Trade-Wind

®

 VSL Liners (non-

internal motor models) are also designed for use with ―in-line‖ and ―remote-mount‖ 

ventilators.  When planning for installations using these products, please refer to the Installation Instructions 
provided with the ventilator.  Trade-Wind

® 

Duct Silencers are available from your local Trade-Wind

®

 

dealer.  When 

planning for installation using a duct silencer, please refer to the Installation Instructions provided with the duct 
silencer. 
 
Given that most installations are different, a back-draft damper is not provided with this unit.  Trade-Wind

® 

back 

draft dampers are also available from your local Trade-Wind

® 

dealer.  Always install ventilation products with an 

approved wall or roof cap.  Duct performance is improved by using round, smooth metal duct work instead of 
rectangular.  If multiple elbows must be used, ensure that there is a minimum of 24‖ of straight duct between any 
two elbows.  Avoid ―S‖ or back to back configurations caused by adjacent elbows.  Do not rely on duct tape alone to 
seal duct joints.  Use sheet metal screws as required to support the duct.  
 
 
 

WARNING! 
For maximum ventilation performance, the bottom of the hood or liner should be 30 - 36 inches (76.2 - 91.4 
cm) abo

ve the cooking surface (minimum is 24”).  This would typically result in the bottom of the hood 

being 66 - 72 inches (167.6 - 182.9 cm) above the floor.  These dimensions provide for safe and efficient 
operation of the hood.  

Always observe local building codes.

  

 

 

 
Important Cut-out Information 

Cabinet or hood cutouts should be at least 1/8‖ larger that the following outside dimensions 
 

 

 

 

Models Available (by Width) 

 

 

 

Pic 

CFM 

28.5” 

34.5” 

40.5” 

46.5” 

Sones 

Control 

Blower 

VSL430 BF 

VSL436 BF 

VSL442 BF 

VSL448 BF 

N/A 

Variable 

In-Line or 

Remote Mount Blower 

410 

VSL430-4 BF 

VSL436-4 BF 

VSL442-4 BF 

Variable 

Internal Motor 

660 

VSL430-6 BF 

VSL436-6 BF 

VSL442-6 BF 

VSL448-6 BF 

7.5 

3-Speed 

Internal Motor 

1360 

VSL442-12 BF 

VSL448-12 BF 

8.5 

Two, 3-Speed 

Two Internal Motors 

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Notes: 

1.  Center of electrical access is 2-

1/4‖ from front & 3-1/2‖ from 

side of liner.  Connection access is behind filters. 
2.  Vent is 8‖ (30 & 36‖ widths) or 10‖ (42‖ & 48‖ widths).  Damper 

not

 included. 

3.  Length & width cutouts should be 1/8‖ larger than above 
dimensions.

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Notes: 

1.  Center of electrical access is 2-

1/4‖ from front & 3-1/2‖ from 

side of liner.  Connection access is behind filters. 
2.  Vent is centered left to right.  Damper

 is

 included. 

3.  Length & width cutouts should be 1/8‖ larger than above 
dimensions.

 

 

Содержание VSL430 BF

Страница 1: ...installer Failure to properly install this product may void the warranty Installer Please leave Installation Instructions with the range hood liner Owner Please keep Installation Instructions for local electrical inspector s use and for future reference WARNINGS Must be followed carefully to avoid personal injury IMPORTANT Must be followed carefully to avoid damage or incorrect installation TIPS C...

Страница 2: ...ner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN YOU MAY BE BURNED c DO NOT USE WATER including wet dishclothes or towels A violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained i...

Страница 3: ...2 pages to electrician PART 1 Planning the Installation Trade Wind Designer Series Liners are designed for installation inside custom hood canopies Proper installation of the liner is directly related to the material from which the custom canopy is constructed A qualified person must complete the installation of this unit Because of the large size and weight of this hood liner two installers are r...

Страница 4: ...rews as required to support the duct WARNING For maximum ventilation performance the bottom of the hood or liner should be 30 36 inches 76 2 91 4 cm above the cooking surface minimum is 24 This would typically result in the bottom of the hood being 66 72 inches 167 6 182 9 cm above the floor These dimensions provide for safe and efficient operation of the hood Always observe local building codes I...

Страница 5: ...hree screws along the back top or back side panel and three screws on the front top immediately next to the light bar wall or behind the removable light bar Where possible the screw holes should be drilled into the top of the liner instead of the sides or back This will help prevent distorting the liner walls in situations where the wood frame is not properly sized to the liner Models with interna...

Страница 6: ...LEANING Proper cleaning is necessary to maintain performance and appearance while also ensuring safe operation The frequency of cleaning should be according to the type and amount of cooking Best results will be achieved by cleaning soiled components as soon as possible Filters must be cleaned regularly Remove one filter at a time by gently inserting a butter knife into the safety slot on the filt...

Страница 7: ...ps or 700 watts CAUTION The neutral wire usually white for the blower motor must connect to the same neutral wire that comes from the electrical panel to the liner It is recommended to run a white neutral wire from the liner s white neutral wire along the same path as the red wire from the liner s variable speed control to the blower motor Variable Speed Control Wiring Details for remote blowers u...

Страница 8: ... Blowers Models VSL430 BF VSL436 BF VSL442 BF VSL448 BF Diagram 3 Models Connected to 3 Speed Roof or Wall Mounted Blowers IMPORTANT Connections to 3 Speed Blowers Require a 5 wire connection to the blower See details on previous page Models VSL430 BF VSL436 BF VSL442 BF VSL448 BF ROOF OR WALL REMOTE BLOWER 3 SPEED CONTROL Installed in Liner or a Wall Location White Black 120 VAC NEUTRAL Medium Sp...

Страница 9: ...care of the product correct faulty installation change fuses or reset breakers Universal Metal Industries Inc disclaims and excludes any liability for implied warranties or for incidental or consequential damages wherever permitted by law There are no implied warranties of merchantability or fitness for a particular use or purpose This warranty gives you specific legal rights and you may also have...

Отзывы: