Tractel HF 32/2/A Скачать руководство пользователя страница 2

MS 32/2/A R 03/03

2

GENERAL WARNING

  

  2

INSTALLATION OF  HF 32 LOAD CELL

3 – 4 - 5

OPERATION AND ADJUSTMENT OF HF 32 LOAD CELL

  6

WIRING OF HF 32 TWO TRIP POINTS

  7

GENERAL WARNING

1- Reading and fully understanding the technical data sheets relating to this

equipment is essential for the best use of this high technological material
that you have received . All the technical data sheets are available on
request.

2- Before installing and operating Dynasafe equipment it is essential for the

safe and correct operation of the material that this manual be read and fully
understood and that all the instructions be followed. This manual should be
made available to every operator. Extra copies of this manual will be
supplied on request.

3- The installation and the operation Dynasafe equipment should only be

carried out in accordance with the appropriate health and safety at work
regulations.

4- Never apply to the Dynasafe a load or an effort in excess of the working

load limit, and never use it for an operation for which it is not intended.

5- TRACTEL S.A.S declines any responsibility for the consequences of

dismantling or altering the machine by any unauthorized person.

6- Dynasafe equipment must not be used in explosive atmospheres. 

7- Dynasafe equipment must only be used in a system designed for lifting

people after ensuring that the appropriate operating coefficients have be
used in accordance with the current regulations.

8- Prior to the use of Dynasafe equipment with complementary equipment

relaying the signals to an operating system, the user or installer of this
system should carry out a specific risk analysis of the operating functions.
The appropriate measures should be taken to obviate risks identified.

Содержание HF 32/2/A

Страница 1: ...MS 32 2 A R 03 03 1 HF 32 2 A Universal load cell Including wiring for 2 trip points equipment in accordance with CE directives Operating and maintenance manual ...

Страница 2: ...eration Dynasafe equipment should only be carried out in accordance with the appropriate health and safety at work regulations 4 Never apply to the Dynasafe a load or an effort in excess of the working load limit and never use it for an operation for which it is not intended 5 TRACTEL S A S declines any responsibility for the consequences of dismantling or altering the machine by any unauthorized ...

Страница 3: ...tening screws J symetrically 0 5 kgm to ensure that there is no risk of moving the load cell out of line with the wire rope Excessive tightening may break the bracket Operate the lifting system up to the upper limit switch and ensure that the sheaving or bottom block does not foul the load cell If this happens adjust the upper limit switch so that there is an appropriate distance between the load ...

Страница 4: ...ecause you risk to destroy the transducer To select pin and bracket position load has priority over wire rope diameter Never remove the locking nut G because tare screw F could damage the microswitch For wire rope from 22 mm to 26 mm diameter and for loads ranging from 500 kg to 6000 kg For wire rope from 17 mm diameter and for loads ranging from 300 kg to 2300 kg For wire rope from 18 mm to 22 mm...

Страница 5: ...ightening bracket depending on the diameter of the wire rope Fig 3 Rubber compression pad M6 screws 40 mm x2 M6 screws 50 mm x2 17 mm wire rope without the rubber compression pad M6 screws 40mm supplied 18 mm to 25 mm wire rope without the rubber compression pad M6 screws 50mm supplied ...

Страница 6: ...lue permitted under the European directives If an overload situation is detected in the wire rope without lifting the loads the preadjustment of the load cell in the factory is too low for your lifting system Solution release the tare screw F see fig 4 one turn at a time and restart at the beginning of point 1 2 To adjust the safety trip point Use the tare screw F Warning incorrect adjustment may ...

Страница 7: ...at washer C Adjust pin D Locking ring E Load cell body F Tare screw for trip point N 1 G Locking nut for trip N 1 F Tare screw for trip point N 2 G Locking nut for trip N 2 H Traction part I Safety washer J Tightening screw K Tightening bracket L Rubber compression pad M Wire rope N Fixing screws for circuit breaker S 1 S 2 Trip point 1 intermediary GREEN BROWN NC 4 A 220 Vac WHITE BROWN NO 4 A 22...

Страница 8: ...MS 32 2 A R 03 03 8 NOTES ...

Отзывы: