![Tractel Dynarope HF 36 Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/tractel/dynarope-hf-36-series/dynarope-hf-36-series_operation-and-maintenance-manual_1147579008.webp)
CUSTOM CALIBRATION IN SPECIAL MODE
This process (made by the customer) allows to correct the “raw” signal provided by the sensor for a
given wire rope at a given strain. Contrary to a specific calibration made by the factory that gives a
correction with a formula.
A memory for 200 Custom calibrations is available.
In order to memorise the parameters of a given situation, prepare an installation as described below.
(Or insert a dynamometer in the installation on the actual site.) and follow the user manual instruction.
See : Calibration process in the Special Mode.
Calibration process
1.
Fig 2
fixed end
Wire rope
Identical to the actual installation
Length : from 0,5 m to
∞
Tensioner
Dynafor LLX
Fixing end. flexible or rigid
according to the actual installation
Working
load
Working load
+
load cell incidence
Adjust and memorise the parameters
following the user manual.
See : Calibration process in Special Mode
Fig 1
Bring the wire rope in contact
with the resting plate
50%
10%
100%
RS232
POWER
On/Off
S
E
F1
F2
F3
Shift
T are
CAPTEUR
H F 8 7 / P/ 1
5