22
10. STORAGE, TRANSPORT, DISPOSAL
Storage: Place the appliance in its original packaging, with the sensor batteries removed. Keep in a
warm, dry place.
Transport: Transport the appliance in its original packaging.
IMPORTANT: Avoid subjecting the dynafor™ LLX1 to shocks.
Disposal: Any disposal of the appliance must be carried out in compliance with the regulations in force
in the country of use. For countries subject to European regulations, the dynamometers and
remote controls (display units) do not come under the terms of the "DEEE" and "RoHS"
directives.
11. OPERATING ANOMALIES AND TROUBLESHOOTING
Display
Possible causes
Solutions
No initial reset
Tare Function enabled.
Permanent deformation of
the sensor following a
handling error; excessive
overload or compression.
Disable the Tare function and
display the "GROS" stress
value.
The appliance should be
checked by the
manufacturer before you
continue using.
The sensor does not
switch on
Dead batteries.
Electronic fault.
Change batteries.
Contact the after-sales service.
The display unit does not
switch on
Dead power pack.
Electronic fault.
Charge power pack.
Contact the after-sales service.
No display evolution or
display inconsistent.
Sensor or sensor electronics
malfunction.
Reset: Switch off the sensor
and display unit and then
switch on the sensor followed
by the display unit.
In the event of persistent
malfunction, contact the after
sales service.
Linearity or precision
problem.
Sensor or sensor electronics
malfunction.
Contact the after-sales service.
GB