Sine wave tests
10)
Insert
1Khz, -20dBu (77mVrms)
sine wave into the
PASSIVE INPUT
.
Turn up
GAIN I
fully then adjust
MASTER
until the output starts to clip.
Check the power is
>400W (40vrms @ 4
Ω
Ω
)
and the
EM84
display valve is fully lit.
Using screwdriver handle gently tap each valve and check for microphony and instability.
11)
Switch to
HALF POWER
mode. (on rear panel)
Check there is a reduction in output power
(~25vrms @ 4
Ω
Ω
)
. Return to
FULL POWER
.
12)
Turn
GAIN I
back to half way. Insert sig. gen. lead into
ACTIVE INPUT
and then back into
PASSIVE
. Check that when in
ACTIVE
the output level approximately halves.
13)
Press
BRIGHT
, signal should increase slightly.
14)
Pull out
GAIN II
. Check signal on scope is as shown:-
Adjust
GAIN II
&
LEVEL
controls to check smooth operation.
Return to half way.
15)
Push
DEEP
. Signal should increase slightly. Push out again.
16)
Turn
TREBLE
,
MIDDLE
&
BASS
to minimum.
Turn
BASS
to maximum, check signal on scope:-
Return to minimum.
17)
Turn
MIDDLE
to maximum, check signal on scope:-
Return to minimum.
18)
Turn
TREBLE
to maximum, check signal on scope:-
Return controls back to half way.
Push in
GAIN II
. Signal should be clean again.
19)
Switch on
COMPRESSOR
, signal should increase slighlty.
Turn up
LEVEL
, the blue LED should be lit just before full.
Turn off
COMPRESSOR
, blue LED should fade out.
Rear Panel
20)
Check that none of the rear LED’s are lit.
Using a screwdriver remove each fuse, one at a time. Check each LED lights up.
21)
Check correct functionality of 2 way foot switch socket.
Tip should switch from
GAIN I
to
GAIN II
, ring switches
COMPRESSOR
on/off.
22)
Check there is an output at the correct level from the following sockets:-
DI OUT
– (POST/GROUND)
~20mV p/p
DI OUT
– (PRE/GROUND)
~350mV p/p
LINE OUT
~1.2V p/p
SEND
~200mV p/p
23)
Turn
MASTER
control to minimum and switch unit to
STANDBY
.
Connect output to appropriate speaker cabinet and bass guitar
Aurally test main features of each channel and check for any excessive hum or noise.
24)
Connect to load & sig. gen., set up for full power and soak test for approx. 30 minutes.
End of test.