5.1 DSP 402 state machine
If the drive is in
OPERATIONAL
status, drive-specific functions can be addressed.
Figure 9 provides an overview of the states (Sx) defined in the DSP 402 drive profile
and the transitions between these states (Tx). The current status is shown by the
status word 0x6041. In Figure 9 the states are represented by rectangles. The state
transitions are marked by arrows, which specify the condition for the corresponding
transition. In most cases this is a command in the control word 0x6040. In an error
situation, you go from each of the states into the state
“S7: Fault reaction active” (Error
reaction active).
S1-S8: Operation states (
S
tates)
T0-T16: State transitions (
T
ransitions)
S1
Not ready to switch ON
S2
Switch ON disabled
S3
Ready to switch ON
S4
Switched ON
S5
Operation enabled
RUN/HALT
S6
Quick stop active
S8
Fault
S7
Fault reaction active
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
ALL STATES
T13
T14
T15
T16
START
T3'
Figure 9: DSP 402 state machine