![TR-Electronic LP-46-K Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/tr-electronic/lp-46-k/lp-46-k_user-manual_1146673075.webp)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2009, All Rights Reserved
04/23/2020
TR - ELA - BA - DGB - 0015 - 13
Page 75 of 92
Bit coded operating parameters
Byte
X+0
Bit
7
– 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Interpolation
off
X
on
1
Counting direction
increasing position values
to the rod end
X
decreasing position
values to the rod end
Operating parameter Resolution
Description see page 82
unsigned16
Byte
X+1
X+2
Bit
15
– 8
7
– 0
Data
2
15
– 2
8
2
7
– 2
0
Default (dec.)
5 µm (1…1000)
Resolution
Operating parameter Number of magnets
Description see page 82
bitarea
Byte
X+3
Bit
7
6
5
4
3
2
1
0
Data
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1 magnet
(default)
0
0
0
0
0
0
0
1
2 magnets
0
0
0
0
0
0
1
0
3 magnets
0
0
0
0
0
0
1
1