Programming
TR-Electronic GmbH 2014, All Rights Reserved
Printed in the Federal Republic of Germany
Page 28 of 32
TR - E - TI - DGB - 0103 - 05
06/21/2016
5.3 Basic parameter
5.3.1 Protocol-Type
Selection
Description
Default
TRWinProg
The measuring system to be programmed must be
TRWinProg compatible.
X
Serial Line
only for service purposes
Serial
only listening
for internal logging
SSI-Master
In a SSI network the adapter can be used as a master.
SSI-Passive
In a SSI network the adapter can be used passively.
LJU-Protocol
The measuring system to be programmed must be LJU
compatible.
5.3.2 Output Interface
Selection
Description
Default
RS485
The transmission is established as RS485 interface.
X
K-Line or
CAN-Driver
The transmission is established as K-Line or CAN
interface.
5.3.3 Firmware-Update enabled
For the initialization of a firmware update of the adapter the numbers "12345" can be
entered here. "0" means that no firmware update is permitted at the moment.
5.3.4 Hardware-Interface
Shows which interfaces are supported by the respective adapter variant. The
hardware variants are indicated by different article numbers, see "Hardware versions"
on page 23.
5.3.5 Low-Address HID-Device
By means of this attribute the low byte of the HID device addresses can be set
manually for adapter identification. For the adapters attached to the PC the address
range from 0x61 to 0x67 is available. At the PC each address can be set only once, 7
adapters per PC are possible therefore.
5.3.6 LJU-Preset
Manufacturer specific function for the LJU interface.