Printed in the Federal Republic of Germany
TR-Electronic GmbH 2013, All Rights Reserved
09/23/2014
TR - ECE - BA - DGB - 0102 - 03
Page 145 of 171
8.4.3.35 Attribute 109, Temperature High Limit
Temperature Low Limit
defines the maximum value of the temperature with the
unit that is defined in “Attribute 107, Temperature Value Format” it is standardly °C. If
this value is exceeded in “Attribute 47, Warnings” the depending warn bit (14) is set to
high.
INT, Default: + 85 °C
Temperature Low Limit
Byte 0
Byte 1
2
7
up to 2
0
2
15
up to 2
8
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x6D
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #109
To save this attribute permanently the attribute 112
Accept Parameter
or service
code 0x16
save
must be executed.
8.4.3.36 Attribute 110, Additional Vendor-Parameter 1
Reserved for further functions.
8.4.3.37 Attribute 111, Additional Vendor-Parameter 2
Reserved for further functions.
8.4.3.38 Attribute 112, Accept Parameter
Accept Parameter
complies to the service code 0x16 (Save Paramter) and saves
the measuring system parameter into the non-volatile memory (EEPROM).
With write access ≠ 0 all changed attributes are stored permanently and the
acceptance of changed values for the instance attributes is performed.
Attr.-ID
112
Data type
USINT
Access
Set / Get
Lower limit
0
Upper limit
255
Default
0