4.FRONT PANEL DESCRIPTION
1) IR sensor
2) Laser pointer beam
3) LCD Display
4) Down button
5) Up button
6) Mode button
7) Laser/Backlight button
8)
Measurement Trigger
9)
Handle Grip
10) Battery Cover
5.INDICATOR
1) Data hold
2) Measuring indication
3) Emissivity symbol and value
4) Low battery, lock and laser “ON”
symbols
5) Backlight “ON” symbol
6)
o
C /
o
F symbol
7) High alarm and low alarm symbol
8) Temperature values for the MAX, MIN, DIF, AVG HAL and LAL.
9) Symbols for EMS, MAX, MIN, DIF, AVG, HAL and LAL.
10) Current temperature value
6.BUTTONS
1) Up button (for EMS,HAL,LAL)
2) MODE button
(for cycling through the mode loop)
3) Down button (for EMS,HAL,LAL)
4) Laser/Backlight ON/OFF button
(pull trigger and press button to activate
laser/backlight)
MODE Button Function
The infrared thermometer measures
Maximum (MAX), Minimum (MIN),
Differential (DIF), and Average (AVG)
Temp. Each time you take a reading.
This data is stored and can be recalled
with the MODE button until a new
measurement is taken. When the trigger
is pulled again, the unit will begin
measuring in the last mode selected.
Pressing the MODE button also allows
you to access the High Alarm(HAL),Low
Alarm(LAL),
Emissivity(EMS).Each time you press
MODE ,you advance through the mode
cycle.
The diagram shows
the sequence of functions in the
MODE cycle.
Switching
o
C
/
o
F,
LOCK ON/OFF and SET ALARM.
①
o
C
/
o
F
②
LOCK ON/OFF
③
SET ALARM
Select the temperature units (
o
C or
o
F)
using the
o
C
/
o
F
switch
To lock the unit on for continuous measurement, slide the middle switch
LOCK ON/OFF
right. If the trigger is pulled while the unit is lock on, the laser
and backlight will turn on if they have been activated. When the unit is
locked on, the backlight and laser will remain on unless it is turned off using
the
Laser/Backlight
button on the keypad.
To activate the alarms, please slide the bottom switch
SET ALARM
right.
To set values for the High Alarm (
HAL
), Low Alarm (
LAL
) and Emissivity
(
EMS
), firstly active the display by pulling the trigger or press the
MODE
button, then press the
MODE
button until the appropriate code appears in
the lower left corner of the display, press the
UP
and
DOWN
buttons to
adjust the desired values.
7.MEASUREMENT OPERATION
1) Hold the meter by its
Handle Grip
and point it toward the surface to be
measured.
2) Pull and hold the
Trigger
to turn the meter on and begin testing. The
display will light if the battery is good. Replace the battery if the
display does not light up.
3) While measuring, the SCAN display icon will appear ins the upper left
corner of the LCD.
4) Release the Trigger and the HOLD display icon will appear on the LCD
indicating that the reading is being held.
5) The meter will automatically power down after approximately 7
seconds after the trigger is released.(Unless the unit is locked on)
Note: Measurement considerations
Holding the meter by its handle, point the IR Sensor toward the measure
object. The meter automatically compensates for temperature deviations
from ambient temperature. Keep in mind that it will take up to 30 minutes
to adjust to ambient temperatures. After performing high temperature
measurements, some time (several minutes) is required before new
measurements can be performed. This is a result of the cooling process,
which must take place for the IR sensor.
8.BATTERY REPLACEMENT
1) As battery power is not sufficient, LCD will display “ ”
replacement with one new battery type 9V is required.
2) Open battery cover, then take out the battery from instrument and
replace with a new 9-Volt battery and place the battery cover back.