Minimum Clearance
When the appliance is running, ensure the filter screen and the cold air ducting are 300mm
minimum from the wall or other obstacles, and the hot exhaust pipe is 900mm minimum
from the ceiling or other obstacles.
Adjustment Air Range
The cold air duct can rotate left or right to 360degrees (hot air exhaust duct is installed)
The cold air duct may be moved up or down to 150degrees
The range of adjustment angle for the hot air exhaust duct is 45degrees
WARNING -Adjust the cold air duct prior to use and adjust the air out direction of
the hot exhaust duct later. When adjusting the flow angle of the cold air duct, grip the
elbow for adjustment – do not hold on to the cold air duct directly.
Condensation Tank
A 5Litre polyethylene condensation tank in the lower-front compartment of the unit
collects evaporator-coil condensation moisture. When full, simply remove, drain, replace,
and restart. Do not move the machine if the condensation tank is full of water.
To empty the water in the condensation tank, ensure the end face on the tank handle is
parallel. Rotate the control switch to 0. Empty the water in a resourceful manner and
reinstall the condensation tank before restarting Air Conditioner.
Pipe Drain (optional)
Condensation water may be discharged directly from the Air Conditioner drain pipe.
Remove the water tank and empty, push the optional drain pipe on to the appliance outlet
inside the tank recess. Then locate the drain pipe through the round hole in the
corresponding side plate. Ensure the end of the pipe is below the Air Conditioner.
Compressor Overload/Overheat Protection
The compressor overload protector will be activated to cut the power of the compressor to “Off” in the event of overly high
or low voltage and/or overly high temperatures.
When the overload protector is activated, the machine will only blow non-refrigerated air.
Contact a qualified service technician if the overload protector is activated frequently.
4.
MAINTENANCE
Disconnect power prior to any maintenance
Inspect the general condition of the Air Conditioner checking:
for loose hardware
cracked, bent, or broken parts, and
any other condition that may affect the Air Conditioners safe operation
Filter Screen
Clean the filter screen regularly using a vacuum cleaner to remove dust and dirt. When required the filter screen can be
cleaned with a cloth and luke warm water. Do not use chemicals. Leave to dry in a shaded area before reinstalling.
NOTE: For effective cooling clean the filter at least every 2 weeks.
Fig11.
Fig10.