Keypad Function/Operation
HOLD
SW
1.
[
]
: Press this key to set the current display to zero. Under weighing mode of
operation to turn on/off the display backlighting (only applicable to LCD series)
2.
[
]
: Press this key to change between Measured Division and Selectable Division.
3
.[
]: Press this key to keep the current display, the screen will flash. Press it again to quit
this operation.
General Scale Operations
1.
Turn On the Scale
Press the mechanical switch located on the back of scale to “1” position to turn on the scale. The
scale’s maximum weighing capacity is first shown, and then the scale goes through a self-check
sequence. After 0.0 is displayed and stable light is lit, the scale is ready for weighing operation.
(Note: it is recommended to allow scale 3~5 minutes of warm-up time before starting weighing
operation).
2.
Zeroing
When the scale is switched on and with no load on the hook, press the ZERO key to obtain
the zero reading. .
3.
Weight Measurement
Once the load is suspended completely, the display shows the weight value of the load. When the
“Stable” indicator is lit, weight value can be recorded. In case there is tare such as cable, load the
tare and press to zero the display to “0”kg. The weight value after this will be the net
weight. This will not change until the tare change or the scale being turned off.
4.
Turn Off the Scale
After weighing operation, the scale should be turned off. Press the mechanical switch on the back
of the scale to “0” position to shut off the power to the scale completely to prevent the leakage of
the battery.
5.
Division Conversion
Under weighing mode and the unit is ‘kg’, press key to change between Measured Division
and Selectable Division
.
Battery Charging Method