Keypad Function/Operation 

HOLD

SW

 

 

 

1.

    

:  Press  this  key  to  set  the  current  display  to  zero.    Under  weighing  mode  of 

operation to turn on/off the display backlighting (only applicable to LCD series) 

2.

 

    

  : Press this key to change between Measured Division and Selectable Division. 

3

.[ 

]: Press this key to keep the current display, the screen will flash. Press it again to quit 

this operation. 

General Scale Operations 

1.

 

Turn On the Scale 

Press the mechanical switch located on the back of scale to “1” position to turn on the scale.    The 

scale’s maximum weighing capacity is  first shown, and then  the  scale goes through  a  self-check 

sequence.  After 0.0 is displayed and  stable  light is lit, the scale is  ready  for  weighing operation.   

(Note: it  is recommended  to allow scale 3~5  minutes of warm-up  time before starting  weighing 

operation). 

2.

 

Zeroing 

When the scale is switched on and with no load on the hook, press the            ZERO key to obtain 

the zero reading. . 

3.

 

Weight Measurement 

Once the load is suspended completely, the display shows the weight value of the load. When the 

“Stable” indicator is lit, weight value can be recorded. In case there is tare such as cable, load the 

tare and press                to zero the display to  “0”kg.    The weight value after this will be the net 

weight.    This will not change until the tare change or the scale being turned off. 

4.

 

Turn Off the Scale 

After weighing operation, the scale should be turned off. Press the mechanical switch on the back 

of the scale to “0” position to shut off the power to the scale completely to prevent the leakage of 

the battery. 

5.

 

Division Conversion 

Under weighing mode and the unit is ‘kg’, press key            to change between Measured Division 

and Selectable Division 

Battery Charging Method 

Содержание OCS-TPS

Страница 1: ...Electronic Crane Scale User s Guide CRANE SCALE OCS TPS ...

Страница 2: ...tents 1 Overview 2 2 Features Specifications 2 3 Keypad Operation 3 4 General Scale Operations 4 5 Battery Charging 5 6 Precautions 5 7 Calibration Method 5 8 Sub menu Function Setup 5 9 Displays 6 10 Schematics 7 ...

Страница 3: ...igit 20 mm FSTN LCD display with back lighting Hanging Fixture 360 degree swirl safe hook shackle Operating Temperature 10 40 Operating Humidity 30 90 RH Low Voltage Indicator Low voltage indicator turns on when the scale power supply voltage is low Power Supply 6V 3 2AH lead acid rechargeable Battery self contained Adaptor Input 100 240V output DV 6V 800mA Auto Power Off 30 minutes after the scal...

Страница 4: ...e 3 5 minutes of warm up time before starting weighing operation 2 Zeroing When the scale is switched on and with no load on the hook press the ZERO key to obtain the zero reading 3 Weight Measurement Once the load is suspended completely the display shows the weight value of the load When the Stable indicator is lit weight value can be recorded In case there is tare such as cable load the tare an...

Страница 5: ...With a fully charged battery the scale can be operated for about 30 hours To prolong the battery life please recharge the battery promptly using for every 20 hours of usage Scale Care 1 For weighing operation please don t load the scale with weight load exceeding the maximum capacity 2 Perform routine inspection and maintenance to ensure operation safety for these basic items a Check for loose bol...

Страница 6: ...uld be with no load 2 Press Key SEt 00000 Confirm zero point when stable display 00000 3 Press Key to add Press Key to move the digit left 1500 00 Load the scale The closer to full capacity the better For example 1500kg 4 Press Key HOLd To store the result once the weighing becomes stable 5 1500 00 System goes back to weighing mode after several seconds Setup Functions in Sub Menu Step Operation D...

Страница 7: ...g Press or to change 0 is invalid 1 is valid 5 Press Stb 0 Zero setting Press or to switch 0 can zero under any condition 1 can zero only obtain the steady reading 6 Press CHt 1 Units conversion between kg and lb Press or to switch 0 is lb 1 is kg 7 Press Applicable to LCD series For LED series please refer to the next step Aut 0 Manual AUTO backlight setup Press or to switch 0 is manual 1 is auto...

Страница 8: ...ED Display kg HOLD LCD Display AM PM AUTO SW kg Weighing in kg HOLD The current weight is kept AUTO Manual or Auto backlighting When this symbol is lit indicating the backlighting will be on during the weighing process Low Battery indication When the lamp flashed the battery needs to be charged ...

Страница 9: ...n this symbol is lit indicating the display value is at selectable division status Stable indicator When this symbol is lit the weighing process is stable and customer can take record of the weight Schematics kg HOLD CRANE SCALE HOLD SW ...

Страница 10: ...hàng cần sự giúp đở xin vui lòng liện hệ đường dây nóng Người Nhận Số Điện Thoại Liên Lạc Hotline 08 62 888 666 08 62 999 111 Võ Hồ Thái Cường 0915 999 111 Tăng Văn Xa 0974 000 333 Tăng Thị Kim Cương 0908 444 000 ...

Отзывы: