FGH300    

 

              

 

 

 

 

WEIGHING 

Before weighing 

Whenever possible, please allow the balance to warm up for 10 minutes after first turning to power on, so that the 
balance will function properly and accurately. 

Error messages 

Err-O:    Overload 

:     Low battery 

Calibration may be required before weighing. 

Read "CALIBRATION" first and if necessary, calibrate your scale/balance for accurate weighing. 

Weighing procedures 

1.

 

Press [ON/OFF] to turn on the balance. 

When power is turned on, all display segments appear on LED for a few seconds and finally "0" will appear on the 
display. 

2.

 

Select the weighing unit with [UNIT]. 

Press 

[UNIT]

 to select a weighing unit, e.g. "g"

……. 

Once the unit has been selected, the selected unit will be displayed to the weight value. 

3.

 

Start weighing  

If you do not use a container for weighing 

Verify the reading is "0". If not, press

 [ZERO] 

to display "0". 

Place objects on the weighing platform to weigh. 

When the reading becomes stable, the stable indicator is displayed. 

If you use a container for weighing 

Place an empty container on the platform. 

Wait for the stability indicator to be displayed and press 

[TARE]

Place the objects to be weighed in the container. 

When the reading becomes stable, the stable indicator is displayed. 

FEATURES 

 

Auto calibration                  ● Auto shut off (selectable) 

 

Auto zero tracking                ● Auto backlight (selectable)) 

 

Low battery indication             ●g/…. conversion 

 

Lager LED Display                

 

Net weight/stability indication 

 

Содержание FGH300

Страница 1: ...c Công ty Cổ Phần Cân Điện Tử Thịnh Phát có trụ sở chính tại số 57 Đường Nguyễn Văn Thương Phường 25 Quận Bình Thạnh TP Hồ Chí Minh Nhập Khẩu và phân phối Các bước chuẩn bị thiết bị Đặt cân ở vị trí tránh gió tránh luồng máy lạnh tránh cửa ra vào Lắp lồng kính chắn gió vào cân trước khi sử dụng giúp tăng độ ổn định cho cân Sử dụng cân đúng nguồn điện và nguồn phải ổn định Khi cần hiệu chuẩn cân nê...

Страница 2: ...n báo TARE cân đang ở chế độ trừ bì 4 Đèn báo LO BAT cân đang sắp hết PIN 5 Đèn báo g Cân đang ở đơn vị g 6 Đèn báo ct Cân đang ở đơn vị ct 7 Đèn báo oz Cân đang ở đơn vị oz 8 Đèn báo tl t Cân đang ở đơn vị tl T là đơn vị sử dụng trong ngành vàng gồm 0 0000 lượng chỉ phân ly zem với zem 2 rất chính xác 9 Đèn báo sạc pin in charge Hướng dẫn hiệu chuẩn nhanh Cân kỹ thuật FGH300 Chuẩn bị quả cân cấp ...

Страница 3: ...sau là 1 giờ khi đang sạc biểu tượng của PIN hiển thị sẽ báo trạng thái nạp bình khi nạp đấy thì biểu tương sẽ ngừng lại Lưu ý Tránh bị chai bình và làm hỏng mạch xạc tuyệt đối không được dùng hết sạch bình accu rồi mới cắm xạc khi xạc đầy thì phải rút nguồn xạc Sử dụng đúng sạc theo cân không cắm xạc liên tục khi bình đã đầy khi không sử dụng cân trong thời gian dài thì nên xạc định kỳ mổi tháng ...

Страница 4: ...FGH300 4 COMPACT SCALE BALANCE INSTRUCTION MANUAL ...

Страница 5: ...en using the scale the following safety precautions should always be followed WARNING Use only the correct AC adaptor with the scale Other adaptors may cause permanent electrical damage CAUTION Avoid placing the scale in direct sunlight this may cause discoloration or malfunction Replace all batteries at the same time Do not replace only a portion of the 4 batteries as this may cause a malfunction...

Страница 6: ...FGH300 6 ...

Страница 7: ...for 8 to 10 hours When the charging is done the Orange indicate lights will turn into Green Over time charging will cause permanent damage 2 To use only the charger adapter supplied with the indicator 3 If after recharging and the battery does not last long replace with new battery ...

Страница 8: ...econds our default setting is 2 0 press ZERO key to enter ZERO setting display shows RZD XX press UNIT key to select ZERO value 0 8d 1 8d 2 8d 3 8d our default setting is 0 8 press ZERO key to enter FIL setting press UNIT key to select filter range amend 0 1 2 3 4 5 6 7 2 is default setting press ZERO key to select zero range when turn on the scale press UNIT key to select percent 2 3 4 5 8 10 20 ...

Страница 9: ...UNIT to select a weighing unit e g g Once the unit has been selected the selected unit will be displayed to the weight value 3 Start weighing If you do not use a container for weighing Verify the reading is 0 If not press ZERO to display 0 Place objects on the weighing platform to weigh When the reading becomes stable the stable indicator is displayed If you use a container for weighing Place an e...

Страница 10: ...h digits and then Press ZERO the display will show CAL Press ZERO again the display will show X0000 CAL X is flash digit Press UNIT key the flash digit will move to right Press TARE key to increase the flash digit X is the calibration weight which can be set according to your requirement 3 Calibration by the weight When you selected the calibration weight and then place the calibration weight on p...

Страница 11: ...hing Units g lb tl T PCS Stabilization Time 3 seconds Calibration Digital with external weight Display Mode Large LED display Power supply Recharge or AC DC Adapter 10V 500mA 6v 1 3ah Operation Temp 0 40 Net Weight 24350g Shipping Weight 3560g Standard carton 335 x 260 x 340 mm Package 2 Units in one box 555 x 360 x 370 mm Brand VMC Product FURI ...

Отзывы: