Date : 25/08/2013
BIRDY WPs ATEX
Ref : User manual
Version 0.0.3
Page
7/8
3
Important information
3.1 Power supply of BIRDY WPs ATEX
In the frame of BIRDY WPs ATEX using, protection against explosion risk cannot be
guaranteed and will be cancelled if batteries recommended by TPL Systèmes are not used.
The batteries which can be used in BIRDY WPs ATEX are the following ones (and only
these ones):
o
Energizer E91
o
Duracell MN1500
Using a rechargeable 1.2V battery is not allowed
Battery replacement must be done in an area free of explosion risk (non ATEX area).
Respect the polarity of the battery
The battery door must be keeped and repositioned after each battery replacement.
3.2 Programming BIRDY WPs ATEX
BIRDY WPs ATEX programming can only be done by a certified distributor.
If the safety label sticked on the programming contacts protection has been ripped open,
the protection against the explosion risk cannot anymore be guaranteed; in such a case,
this guaranty will be cancelled as well as the manufacturer’s warranty.