TPL VISION M-EBAR Series Скачать руководство пользователя страница 6

eqUIPment maIntenance

Cleaning (when the product is switched off)
Please use a soft and dry cloth. Do not use any abrasive material.
Do not use any cleaning solvent or aggressive chemical product.
TPL Vision recommends to use isopropyl alcohol.

USer SecUrIty

do respect the power supply voltages and the connection terminals.

do not modify or dismantle all or part of the product.

do not connect or clean when power is on.

do not watch the lighting source directly, and follow the advice below :

•  If the workstation enables it, interpose a filter that will stop the lighting radiation under fixed or adjustable 

frame between the source and the operator.

•  When these measures cannot be implemented, supply the operators with glasses (class 4) available for sale 

at TPL Vision, or with a dedicated protective mask, that will stop the lighting radiation.

•  Forbid or limit the direct access to the lighting source (exposure into the radiation axis).

•  Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond 

the recommendations of the manufacturer, as for eye irritation is concerned.

•  In any case, ensure that the chosen means properly reduce the exposition quantities (features of screens or 

glasses to be chosen, according to the wavelengths that the operators are exposed to).

USer gUIde

P6/8

PoWer SUPPly

125

250

375

500

Power consumption (average)

7W

14W

21W

28W

Power consumption Strobe mode* (average)

5.6W

11.2W

16.8W

22.4W

Power consumption (peak)

28W

56W

84W

112W

Min. functioning Voltage

20V in the light input

Normal functioning Voltage

24V in the light input (±10%)

Max. functioning Voltage

30V in the light input

*strobed with 20% duty cycle.

Содержание M-EBAR Series

Страница 1: ...nationally However a damaged package must be reported to the carrier on delivery Hand written reservations must be indicated on the delivery order Moreover please send a letter or an email to TPL Vision as soon as possible up to 24 hours after the delivery If the transportation damage has not been stipu lated on the delivery order and reported to TPL Vision in time the package will not be taken ba...

Страница 2: ... 6 During the set up the light has to be switched off and unplugged Please use the delivered nuts and insert them in the groove located in the back of the light The light will be better fixed if you spread the attachment points as indicated on the scheme above You can also use M4 screws not supplied with a tightening torque from 0 5 to 1 5 Nm We also recommend the use of a threadlocker not supplie...

Страница 3: ...5 male points 24V 1 2 3 4 Ground PNP 5 Dim0 10V STROBEPNP 24V NPN 1 2 3 4 Ground STROBENPN 24V 1 2 3 4 Ground PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Front view Top view P3 8 ...

Страница 4: ...optimised for a lifespan 50kh in a 40 C atmosphere In strobe mode the strobing time is directly equivalent to the time during which the strobe entry is activated Strobe PNP NPN PNP from 5 to 24V for 100 ON From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Strobe mode LED are supplied with 100 maximum current Continuous mode after 30ms at 100 LED are supplied at a sa...

Страница 5: ...uct reaches 100 of its lighting power Only usable in the Overdrive phase Please consider a tolerance of 5 when measuring the dimmed bri ghtness levels STROBE INPUT 30 ms 15 µs 15 µs 15 µs 15 µs LIGHT CONTINUOUS WORKING triggering input 30 ms STROBE MODE triggering input 30 ms x 2 4 x 1 STROBE INPUT 30 ms 15 µs 15 µs 15 µs 15 µs LIGHT CONTINUOUS WORKING triggering input 30 ms STROBE MODE triggering...

Страница 6: ...ailable for sale at TPL Vision or with a dedicated protective mask that will stop the lighting radiation Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond the recommendations of the manufacturer as for eye irritation is concerned In any case ensure that ...

Страница 7: ......

Страница 8: ...se School Road Charing Kent TN27 0JW UK Tel 44 0 1738 310 392 www tpl vision com Features and presentations liable to changes without notice Documentation valid from June 2017 until further notice Ref UG 010801 B1 2020 07 edition ...

Отзывы: